GREAT EAGLE is a 2017 passenger vessel (inspected). The Coast Guard has recorded 28 inspections since 2017, most recently in April 2026, along with 14 deficiencies and 1 casualty investigation in 2019.
Records from 2017 to 2026. Most recent: inspection, 30 April 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
DocumentationValid · issued 13 November 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it59 - Convention (Subpart B), Net Ton 61 - Regulatory (Subpart C or D), Net Ton 162 - Convention (Subpart B), Gross Ton 90 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 28
30 April 2026Damage Survey · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8358962
10 March 2026Annual Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8319675
7 January 2026Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8291465
6 January 2026In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8291077
18 March 2025Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8095456
11 March 2025Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8091357
19 March 2024Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7881168
15 September 2023Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7792147
29 March 2023Internal Structural Exam · Hull Examination · Construction Oversight
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7656181
21 March 2023Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7654155
28 February 2023Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7642951
22 March 2022COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7413700
13 April 2021Administrative Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7174545
9 March 2021Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7152251
24 March 2020Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6960898
20 November 2019Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6859469
26 March 2019Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6649628
22 March 2019Deficiency Check · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6647623
22 March 2019Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6647794
13 March 2019Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6639963
30 January 2019Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6616134
16 November 2018Administrative Inspection
Administrative · Navigation Center · Activity 6581916
26 April 2018In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6436273
14 March 2018Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6371616
24 January 2018Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6350711
28 November 2017Examination of Repairs · Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6313908
16 May 2017In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6147204
2 March 2017Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6097510
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 March 2026Resolved
A vessel must compy with the structural design requirements of one of the standards listed below for the hull material of the vessel. Vessel sustained damage to starboard quarter rub rail affecting 2 frames in the lazarette. Repair affected area to satisfaction of OCMI.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2026
Resolved 24 March 2026
Resolution: Attended vessel to inspect final weld and NDT. All sat.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 10 March 2026Resolved
System design and installation must be in accordance with the Marine Design,Installation, Operation, and Maintenance Manual approved for the system by the Commandant. Annual inspection report shows that time delays for FM-200 released at 29 seconds which is outside the acceptable range per the manufacturers manual. Retest time delays or replace as necessary.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2026
Resolved 13 March 2026
Resolution: Received satisfactory test report from Sea Safety.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 February 2023Resolved
Vessel experienced a loss of propulsion on port engine, reducing the maneuverability of the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2023
Resolution: Received tech report and conducted satisfactory sea trial.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 April 2021Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for normal and emergency conditions.
Electrical conductor on port side VHF Radio overheated and melted electrical insulation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 April 2021
Resolved 13 April 2021
Resolution: Company electrician replaced wire and conducted operational checks of the VHF radio. All sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 March 2021Resolved
Crop out a 12” section on port rubrail that is punctured and weld a new face onto the extrusion as stated in approved repair proposal.
Action required: 705 - Other - as specified
Resolved 23 March 2021
Resolution: Rubrail repaired.
A VESSEL'S HULL SHALL BE WATERTIGHT TO PREVENT HAZARDS TO THE VESSEL AND PERSONS BEING TRANSPORTED. AS A RESULT OF AN ALLISION WITH A FENDER AT THE PIER, THE VESSEL HAS AN APPROXIMATE 4" PUNCTURE IN THE STARBOARD HULL, IVO THE ENGINE ROOM SIDESHELL PLATING, NEAR THE WATERLINE. PERMANENT REPAIRS TO BE MADE AND VERIFIED BY A CGMI.
46CFR177.300(d)
46CFR185.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 March 2019
Resolution: Hull repaired and sat NDT performed.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 16 November 2018Resolved
Vsl is not broadcasting static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 8 March 2021
Resolution: Vessel properly broadcasting draft.
Construction/Loadline › Hull › Hull Plating
Issued 28 November 2017Resolved
DUE TO THE EXTENSIVE CORROSION IDENTIFIED ON THE H100 SERIES VESSELS, THE VESSEL'S HULL MUST BE MADE AVAILABLE FOR INSPECTION BY A COAST GUARD MARINE INSPECTOR. PRIOR TO STARTING ANY WORK, A REPAIR PROPOSAL SHALL BE SUBMITTED TO THE SECNY OFFICE FOR REVIEW AND APPROVAL. ALL REPAIRS MUST BE CONDUCTED IN ACCORDANCE WITH THE APPROVED REPAIR PLAN, AND INSPECTED BY THE ATTENDING MARINE INSPECTOR.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 January 2018
Resolution: Conducted in-service inspection to verify all reapirs.
Documentation › Certificates/Documents › Stability Letter
Issued 4 May 2017Resolved
Place approved stability letter onboard the vessel.
Action required: 705 - Other - as specified
Resolved 18 May 2017
Resolution: Vessel has stability letter dated 16MAY2017.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 4 May 2017Resolved
Prove proper operation of the installed Magna Lock system to include when power failure occurs the system is de-energized to open all doors.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 9 March 2021
Resolution: All magna door lock system components have been removed.
Operations/Management › Vessel Safety Management › Company Verification/Review/Evaluation
Issued 17 April 2017Resolved
Conduct new to xone inspection prior to operating to determine zone specific aoperational constraints and route limitations.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 18 May 2017
Resolution: NTZ complete.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 2 March 2017Resolved
Install approved all power HPII lighting drives with over current protection.
Condition: Improper Installation
Due 3 June 2017
Resolved 18 May 2017
Resolution: New drivers installed.
22 March 2019Routine · role: Involved in a Marine Casualty · activity 6647794
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.