← All vessels
GREAT EAGLE
Passenger (Inspected) · Passenger Ship class · Built 2010s · USCG Northeast District (CGD-NE) · Other hulls named GREAT EAGLE
GREAT EAGLE is a 2017 passenger vessel (inspected). The Coast Guard has recorded 28 inspections since 2017, most recently in April 2026, along with 14 deficiencies and 1 casualty investigation in 2019.
Records from 2017 to 2026. Most recent: inspection, 30 April 2026.
- Built
- 2017
- Last inspected
- 30 April 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 14 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2019
Identity
1277576
WDJ 5132
1407141
Flag
UNITED STATES
367784640
Maury page id
psix-1407141
Inspections, by type
…with no type recorded1
Years with a record
10 calendar years (2017–2026)
The 28 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)80.4 ft × 26.2 ft × 9.2 ft
Registered tonnagegross 90 / net 61
ITC dimensions (L × B × D)80.4 ft × 26.2 ft × 9.2 ft
ITC tonnagegross 162 / net 59
BuilderGRAVOIS BOATS LLC · FRANKLIN, LA, UNITED STATES · built 2017
Hull materialAluminum
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 13 November 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it59 - Convention (Subpart B), Net Ton
61 - Regulatory (Subpart C or D), Net Ton
162 - Convention (Subpart B), Gross Ton
90 - Regulatory (Subpart C or D), Gross Ton
61 - Regulatory (Subpart C or D), Net Ton
162 - Convention (Subpart B), Gross Ton
90 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDJ5132MMSI 367784640 · active · compulsorily equipped · granted 25 April 2017, expires 25 April 2027
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 28
30 April 2026
Damage Survey · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8358962
10 March 2026
Annual Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8319675
7 January 2026
Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8291465
6 January 2026
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8291077
18 March 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8095456
11 March 2025
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8091357
19 March 2024
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7881168
15 September 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7792147
29 March 2023
Internal Structural Exam · Hull Examination · Construction Oversight
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7656181
21 March 2023
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7654155
28 February 2023
Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7642951
22 March 2022
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7413700
13 April 2021
Administrative Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7174545
9 March 2021
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7152251
24 March 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6960898
20 November 2019
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6859469
26 March 2019
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6649628
22 March 2019
Deficiency Check · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6647623
22 March 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6647794
13 March 2019
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6639963
30 January 2019
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6616134
16 November 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6581916
26 April 2018
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6436273
14 March 2018
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6371616
24 January 2018
Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6350711
28 November 2017
Examination of Repairs · Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6313908
16 May 2017
In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6147204
2 March 2017
Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6097510
Deficiency record · 14
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 March 2026
Resolved
A vessel must compy with the structural design requirements of one of the standards listed below for the hull material of the vessel. Vessel sustained damage to starboard quarter rub rail affecting 2 frames in the lazarette. Repair affected area to satisfaction of OCMI.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 10 March 2026
Resolved
System design and installation must be in accordance with the Marine Design,Installation, Operation, and Maintenance Manual approved for the system by the Commandant. Annual inspection report shows that time delays for FM-200 released at 29 seconds which is outside the acceptable range per the manufacturers manual. Retest time delays or replace as necessary.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 February 2023
Resolved
Vessel experienced a loss of propulsion on port engine, reducing the maneuverability of the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 April 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for normal and emergency conditions.
Electrical conductor on port side VHF Radio overheated and melted electrical insulation.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 March 2021
Resolved
Crop out a 12” section on port rubrail that is punctured and weld a new face onto the extrusion as stated in approved repair proposal.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 9 March 2021
Resolved
Affect repairs IVO strut areas where 1/8" pitting was observed as stated in approved repair proposal.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 March 2021
Resolved
Repair aft starboard entry gate as stated in approved repair proposal.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 22 March 2019
Resolved
A VESSEL'S HULL SHALL BE WATERTIGHT TO PREVENT HAZARDS TO THE VESSEL AND PERSONS BEING TRANSPORTED. AS A RESULT OF AN ALLISION WITH A FENDER AT THE PIER, THE VESSEL HAS AN APPROXIMATE 4" PUNCTURE IN THE STARBOARD HULL, IVO THE ENGINE ROOM SIDESHELL PLATING, NEAR THE WATERLINE. PERMANENT REPAIRS TO BE MADE AND VERIFIED BY A CGMI.
46CFR177.300(d)
46CFR185.100
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 16 November 2018
Resolved
Vsl is not broadcasting static draft information
Construction/Loadline › Hull › Hull Plating
Issued 28 November 2017
Resolved
DUE TO THE EXTENSIVE CORROSION IDENTIFIED ON THE H100 SERIES VESSELS, THE VESSEL'S HULL MUST BE MADE AVAILABLE FOR INSPECTION BY A COAST GUARD MARINE INSPECTOR. PRIOR TO STARTING ANY WORK, A REPAIR PROPOSAL SHALL BE SUBMITTED TO THE SECNY OFFICE FOR REVIEW AND APPROVAL. ALL REPAIRS MUST BE CONDUCTED IN ACCORDANCE WITH THE APPROVED REPAIR PLAN, AND INSPECTED BY THE ATTENDING MARINE INSPECTOR.
Documentation › Certificates/Documents › Stability Letter
Issued 4 May 2017
Resolved
Place approved stability letter onboard the vessel.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 4 May 2017
Resolved
Prove proper operation of the installed Magna Lock system to include when power failure occurs the system is de-energized to open all doors.
Operations/Management › Vessel Safety Management › Company Verification/Review/Evaluation
Issued 17 April 2017
Resolved
Conduct new to xone inspection prior to operating to determine zone specific aoperational constraints and route limitations.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 2 March 2017
Resolved
Install approved all power HPII lighting drives with over current protection.
Casualty record · 1
22 March 2019Routine · role: Involved in a Marine Casualty · activity 6647794
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.