MAURY USCG vessel records
← All vessels

URBAN JOURNEY

URBAN JOURNEY is a 2017 passenger vessel (inspected). The Coast Guard has recorded 34 inspections since 2016, most recently in March 2026, along with 18 deficiencies, 1 operational control and 1 casualty investigation in 2020.

Records from 2016 to 2026. Most recent: inspection, 16 March 2026.

Built
2017
Last inspected
16 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 March 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ4540
1407331
Flag
UNITED STATES
Maury page id
psix-1407331

Documentation record

Registered dimensions (L × B × D)80.4 ft × 26.3 ft × 9.2 ft
Registered tonnagegross 90 / net 61
ITC dimensions (L × B × D)80.4 ft × 26.3 ft × 9.2 ft
ITC tonnagegross 162 / net 59
BuilderHORIZON SHIPBUILDING · BAYOU LA BATRE, AL, UNITED STATES · built 2017
Hull materialAluminum
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 3 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it162 - Convention (Subpart B), Gross Ton
90 - Regulatory (Subpart C or D), Gross Ton
59 - Convention (Subpart B), Net Ton
61 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 34

16 March 2026 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8326991
20 January 2026 Vessel Attendance
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8298460
18 March 2025 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8095121
22 October 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8022683
18 March 2024 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7883388
12 March 2024 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7877513
22 November 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7828784
15 September 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7792060
5 September 2023 Damage Survey · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7785324
29 August 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7780402
6 June 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7705050
29 May 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7699734
14 March 2023 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7650046
30 October 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7586410
30 September 2022 Internal Structural Exam · Examination of Repairs · Deficiency Check · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7566968
15 March 2022 COI Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7404558
15 March 2021 Annual Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7156632
1 December 2020 Internal Structural Exam · Examination of Repairs · Administrative Inspection · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7104022
1 June 2020 Examination of Repairs · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6966923
28 May 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6963088
27 February 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6916654
20 September 2019 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6816595
7 March 2019 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6637739
22 January 2019 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6614454
15 January 2019 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6611247
30 October 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6570825
30 October 2018 Examination of Repairs · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6570920
29 October 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6572732
13 February 2018 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6354615
9 January 2018 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6350747
29 November 2017 Administrative Inspection · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6317094
20 September 2017 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6271214
17 April 2017 Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6132445
23 June 2016 DAPI Audit · Initial Certification · Hull Examination · COI Inspection · Administrative Inspection · Internal Structural Exam · Plan Review "T" Boat · Construction Oversight · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5966464

Deficiency record · 18

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 November 2023 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Prior to the carriage of passengers, provide causal analysis and corrective action to the satisfaction of a USCG Marine Inspector. 46 CFR 182.200(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 November 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 June 2023 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations Prior to carrying passengers, provide a causal-analysis report identifying the contributing factors that led to the loss of propulsion in the engine, as well as a report from an attending technician certifying that any necessary repairs have been satisfactorily completed, and conduct sea trials with a qualified marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2023
Resolution: See attached tech report.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 15 January 2019 Resolved
Crop and renew two marked cracks/insets on outboard side of starboard hull. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 22 January 2019
Resolution: Witnessed satisfactory cropping and renewing of marked areas and satisfactory NDT of welds.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 15 January 2019 Resolved
Repair corrosion around both shaft struts with Belzona or similar product. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 22 January 2019
Resolution: Observed completion of repairs to shaft struts.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 January 2019 Resolved
Replace missing screw in rub rail on starboard bow in order to fill the hole left in the hull by it. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 23 January 2019
Resolution: Screw replaced and made to not come loose easily.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 January 2019 Resolved
Conduct dye pen test on starboard shaft strut to determine if line is a crack or some other marking. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 18 January 2019
Resolution: Dye Pen test conducted on shaft struts, no cracks.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 30 October 2018 Resolved
Submit a repair proposal plan to the satisfaction of the [name withheld] repairs IAW the repair plan to the satisfaction of the attending CG marine inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 November 2018
Resolution: Repair has been complete.
Construction/Loadline › Hull › Longitudinal Frame
Issued 14 February 2018 Resolved
Cracked weld between frames #4 and #5 in the port side engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2019
Resolved 22 January 2019
Resolution: Crack repaired during dry dock.
Construction/Loadline › Hull › Longitudinal Frame
Issued 14 February 2018 Resolved
Cracked weld in fuel space overhead, starboard side, frame 10.
Action required: 705 - Other - as specified
Due 31 March 2019
Resolved 22 January 2019
Resolution: Crack repaired during dry dock.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 17 April 2017 Resolved
Vessel is not authorized to reduce one deckhand when the upper deck is secured until they conducted a man-overboard drill using one Master and one Deckhand.
Action required: 705 - Other - as specified
Resolved 4 October 2017
Resolution: Vessel representative will contact unit at later date to verify ability to reduce manning.
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 6 April 2017 Resolved
Satisfactorily address all comments listed in MSC’s memorandum to Sector Mobile, dated March 27, 2017, Serial E2-1700949.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2017
Resolved 27 April 2017
Resolution: Received verbal from MSC that LED lighting equivalency was being issued.
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 6 April 2017 Resolved
Provide acceptable rescue platform for use as a person overboard rescue device.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2017
Resolved 13 April 2017
Resolution: SEC NY determined davit and Jacob's Cradle meet the requirements of a Rescue Boat as per 46 CFR 180.210.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 April 2017 Resolved
Conduct new to zone inspection prior to operating to determine zone specific operational constraints and route limitations.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2017
Resolved 27 April 2017
Resolution: Completed NTZ.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 6 April 2017 Resolved
Provide documentation that the installed davit's structure and ancillary equipment are approved for their intended use by USCG MSC.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2017
Resolved 3 May 2017
Resolution: PAE approved by MSC.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 6 April 2017 Resolved
Properly mark each life jacket and ring buoy in clearly legible block capital letters with the vessel's name.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2017
Resolved 17 April 2017
Resolution: Vessel properly marked all lifesaving equipment.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 6 April 2017 Resolved
Prove proper operation of the installed Magna Lock system to include when power failure occurs, the system is de-energized, allowing all doors to open.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 1 December 2020
Resolution: System has been removed.
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 6 April 2017 Resolved
Provide adequate lighting IWO installed davit for man over board recovery at night.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2017
Resolved 13 April 2017
Resolution: SEC NY determined davit and Jacob's Cradle meet the requirements of a Rescue Boat as per 46 CFR 180.210.
Fire Fighting › Fire Pumps › Power Source
Issued 6 April 2017 Resolved
Provide fire pump motor that is rated for 50 degrees Celsius or de-rate motor to 80%.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2017
Resolved 17 April 2017
Resolution: Vessel provide new manufactuer plate verifing 50 degree celsius rating.

Casualty record · 1

28 May 2020Routine · role: Involved in a Marine Casualty · activity 6963088
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.