MAURY USCG vessel records
← All vessels

STARLIGHT

STARLIGHT is a 2017 passenger vessel (inspected). The Coast Guard has recorded 25 inspections since 2016, most recently in August 2026, along with 8 deficiencies and 2 operational controls, 1 with no removal date recorded.

Records from 2016 to 2026. Most recent: inspection, 21 August 2026.

Built
2017
Last inspected
21 August 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
1 with no removal date recorded

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 August 2026
Operational controls 1 with no removal date recorded
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ6505
1407335
Flag
UNITED STATES
Maury page id
psix-1407335

Documentation record

Registered dimensions (L × B × D)80.4 ft × 26.3 ft × 9.2 ft
Registered tonnagegross 90 / net 61
ITC dimensions (L × B × D)80.4 ft × 26.3 ft × 9.2 ft
ITC tonnagegross 162 / net 59
BuilderHORIZON SHIPBUILDING · BAYOU LA BATRE, AL, UNITED STATES · built 2017
Hull materialAluminum
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationTwin Hull
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 4 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it162 - Convention (Subpart B), Gross Ton
90 - Regulatory (Subpart C or D), Gross Ton
59 - Convention (Subpart B), Net Ton
61 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 25

21 August 2026 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8469383
7 August 2026 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8410612
15 September 2025 Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8234761
1 October 2024 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8011912
29 August 2024 Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7991675
18 June 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7937148
15 September 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7792192
12 September 2023 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7786684
15 July 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7742866
25 August 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7543389
9 August 2022 COI Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7528795
15 June 2022 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7477077
14 September 2021 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7311829
24 December 2020 Administrative Inspection · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7115904
13 October 2020 Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7075854
26 August 2020 Plan Review "T" Boat
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7044483
6 August 2020 Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7025487
2 October 2019 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6826116
20 September 2019 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6816497
24 April 2019 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6781081
18 December 2018 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6599632
3 October 2018 Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6553778
3 January 2018 Deficiency Check · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6339368
6 September 2017 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6260780
8 July 2016 Hull Examination · COI Inspection · Plan Review "T" Boat · Administrative Inspection · Construction Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5996673

Deficiency record · 8

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 15 September 2025 Resolved
46 CFR 181.310(A) 701C A VESSEL THAT HAS A POWER DRIVEN FIRE PUMP MUST HAVE A SUFFICIENT NUMBER OF FIRE HYDRANTS. PORT AFT FIRE HYDRANT FOUND TO BE INOPERABLE WITH OBSERVED 1/4" HOLE IN PIPE. REPAIR PIP TO SATISFACTION OF ATTENDING MARINE INSPECTOR.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 September 2025
Resolution: Permanent repair to the fire main pipe was repaired to the satisfaction of the marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 August 2022 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at a constant marine load. Vessel report a loss of propulsion due to high temperature cooling shutdown rendering the starboard engine inoperable causing an undue risk to the port of New York. In order to clear this deficiency the following actions must be carried out: 1. Provide a causal analysis report on the loss of propulsion and provide a repair proposal. 2. Post-approval of repair proposal and upon completion of repairs, provide USCG a tech report delineating all repairs and pier side propulsion test satisfactory. 4. Vessel must undergo an underway sea trial to the satisfaction of an attending marine inspector prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 August 2022
Resolution: The vessel operator for STARLIGHT (O.N. 1278037) submitted causal analysis report, satisfactory repair plan and conducted satisfactory propulsion test.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 24 April 2019 Resolved
Complete all work identified during the April 2019 dry dock inspection. Port Outboard FR 5-6, Damage to plate from frequent collision with pier/fenders ? Starboard Outboard FR 15, vertical crack in weld located behind the frame on the outboard side ? Starboard Bow Quarter FR 19.75, inside the starboard forepeak void it was found that the front plate located behind the bow guard was dented due to collision, cracking the welds on the bottom of the plate ? Port forepeak void cracked weld was found on stiffener ? Corrosion on ½” plate bottom hulls both port and starboard ? Starboard Generator Keel Cooler Pocket, found significant corrosion and coating failure due to continuity between the keel cooler and the hull
Action required: 705 - Other - as specified
Resolved 7 May 2019
Resolution: All repair work is complete.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 3 October 2018 Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead. The starboard watertight bulkhead between the engine room and the lazarette has a small hole where the inner fire suppression bracket is welded.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2018
Resolved 10 October 2018
Resolution: Inspected satisfactory
Electrical › Electric Generation Source (service) › Ground Detection
Issued 3 January 2018 Resolved
Determine source of ground to minimize electrical hazard to crew and passengers. Once ground is discovered, notify the USCG before repairs are conducted.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 10 January 2018
Resolved 9 January 2018
Resolution: MI confirmed ground was removed and ammeter reads 0 amps.
Operations/Management › Pollution › Retention of Oily Mixture
Issued 3 January 2018 Resolved
Remove oily water from engine room bilge.
Action required: 705 - Other - as specified
Due 10 January 2018
Resolved 9 January 2018
Resolution: MI confirmed all oily water was removed from bilge in E/R.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 21 August 2017 Resolved
Conduct new to zone inspection prior to operating to determine zone specific operational constraints and route limitations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 September 2017
Resolved 7 September 2017
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 21 August 2017 Resolved
Prove proper operation of the installed Magna Lock system to include when power failure occurs, the system is de-energized, allowing all doors to open.
Action required: 705 - Other - as specified
Due 21 September 2018
Resolved 13 October 2020
Resolution: Magnalock system has been denergized and is no longer used or in service.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.