← All vessels
HAFNIA DAISY
HAFNIA DAISY is a tank ship. The Coast Guard has recorded 30 inspections since 2016, most recently in March 2026, along with 12 deficiencies and 2 operational controls.
Records from 2016 to 2026. Most recent: inspection, 30 March 2026.
- Built
- Not recorded
- Last inspected
- 30 March 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 12 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9709788 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HA4205
1407587
Flag
MALTA
—
Maury page id
psix-1407587
Inspections, by type
…with no type recorded2
Years with a record
11 calendar years (2016–2026)
The 30 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it29658 - Convention (Subpart B), Gross Ton
49828 - Dead Weight, Metric Ton
61218 - Displacement, Metric Ton
14551 - Convention (Subpart B), Net Ton
49828 - Dead Weight, Metric Ton
61218 - Displacement, Metric Ton
14551 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 30
30 March 2026
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8332994
29 October 2025
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8260572
14 October 2025
COC-CHEM & TVE Annual · PSC B
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8250417
4 March 2025
Bulk Liquid Transfer Monitor
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8088691
23 September 2024
COC-CHEM & TVE Renew
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8001264
16 February 2024
In-Service Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7866434
28 September 2023
Ballast Water Examination · COC-CHEM & TVE Annual
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7797754
17 September 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7560740
15 September 2022
PSC B · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7555688
13 February 2022
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7395701
10 November 2021
In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7346710
26 October 2021
COC-CHEM & TVE Annual · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7340109
2 November 2020
In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7088778
17 September 2020
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7059997
8 September 2020
COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7048992
21 July 2020
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7012497
17 September 2019
ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6813969
21 February 2019
Ballast Water Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6630416
29 November 2018
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6589144
23 November 2018
ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6585389
26 August 2018
COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6522888
26 February 2018
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6368523
16 September 2017
Ballast Water Examination · COC-CHEM & TVE Annual · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6264162
22 June 2017
Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6183502
24 December 2016
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6062082
24 December 2016
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6062229
21 December 2016
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6060985
9 November 2016
In-Service Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6038911
13 October 2016
Administrative Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6030755
6 September 2016
COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5993814
Deficiency record · 12
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 30 March 2026
Resolved
The administration shall satisfy itself what the general structure strength of the hull is sufficient for the drought corresponding to the free-board assigned. PSCOs were notified by a company representative that on 24March2026, the crew discovered seven cracks in the Forward Peak Tank (FPT). On the starboard side of the FPT, there was a 120mm crack on the weld seam between web frame No. 242 and shell plating; a 110mm crack on the shell plating in the space between frames No. 241 and 243; a deformed bracket at frame No. 239; a crack on stiffener at frame No. 238. On the port side FPT, there was a 110mm crack on the weld seam between web frame No. 242 and shell plating; a 60mm crack on the shell plating in the space between frames No. 241 and 243; a crack on stiffener at frame No. 242. The listed damages brings into question if the general structure strength of the hull is sufficient.
ICLL 66/88 Annex 1/Ch. 1 Reg. 1
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 16 February 2024
Resolved
Means shall be provided for stopping the discharge into the sea of ballast water or oil contaminated water from cargo tank areas. Port State Control officer observed oil discharge into the U.S. navigable waterway. Class to verify corrective actions were completed to ensure no further discharge occurs.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 16 February 2024
Resolved
Oil tankers of 150 GT+ shall be equipped with an ODME. Vessel restricted from using ODME until verification that system is operating properly and all lines/piping are free from oil.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 15 September 2022
Resolved
A tanks Overflow control system required by this section shall: Come into operation when the normal tank loading procedures fail to stop the tank liquid level exceeding the normal condition.
On deck, all audible and visual alarms did not operate properly for the overfill alarm system.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 November 2021
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions. A-60 and A-15 fire boundary doors leading to the steering gear room were damaged in an engine room fire.
74 SOLAS (20 Cons.) II-2/14.2.1.1.1
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 8 September 2020
Resolved
04114- Emergency Source of power- Eacg emergency generating set to be automatically started shall be equipped with a starting device approved by the administration, a second independant means shall be provided. PSCO observed that the secondary means of starting was inoperable. SOLAS 74 (2014) II-1/44.2 17ac
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 9 November 2016
Resolved
1170-Cargo tanks shall be fitted with a visual and audible high-level and overflow-control alarms. The vessel's high-level and overflow alarms for tank 01 port side are inoperable. SOLAS 14 CHVII Reg.13 // IBC 15.19.6 and 15.19.7 (16ac).
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 9 November 2016
Resolved
1199-Instrumentation shall be fitted for continuously indication and recording of the inert gas system within the control room. The CPU that monitors IGS in the control room is inoperable. SOLAS 14 CHII-2 Reg. 4.5.5.3.2 // FSS Code Reg. 15.2.4.2.2 (16ac).
Deck/Cargo › Inert Gas System › Venting System
Issued 8 September 2016
Resolved
THE INERT GAS SYSTEM SHALL BE CAPABLE OF INERTING, PURGING, AND GAS-FREEING EMPTY TANKS, AND MAINTAINING THE ATMOSPHERE IN CARGO TANKS WITH THE REQUIRED OXYGEN CONTENT. THE INERT GAS SYSTEM IS INOPERABLE.
Deck/Cargo › Inert Gas System › Venting System
Issued 8 September 2016
Resolved
WHEN THE OXYGEN CONTENT OF THE INERT GAS EXCEEDS 8% BY VOLUME, IMMEDIATE ACTION SHALL BE TAKEN TO IMPROVE THE GAS QUALITY. THE OXYGEN CONTENT EXCEEDS 8%. THE INERT GAS SYSEM IS INOPERABLE.
Electrical › Electric Generation Source (service) › Generator
Issued 8 September 2016
Resolved
THE CONDITION OF THE SHIP AND IT'S EQUIPMENT SHALL BE MAINTAINED TO ENSURE THAT THE SHIP, IN ALL RESPECTS, WILL REMAIN FIT TO PROCEED TO SEA. THE FILTER CLEANER VALVE HANDLES ON GENERATOR NUMBER TWO IS MISSING. ALSO, GENERATOR NUMBER ONE ONLY HAS ONE FILTER CLEANER VALVE HANDLE.
Electrical › Electric Generation Source (emergency) › Switch
Issued 8 September 2016
Resolved
OIL FUEL PIPES, WHICH, IF DAMAGED, WOULD ALLOW OIL TO ESCAPE FROM THE STORAGE TANK HAVING A CAPACITY OF 500L AND ABOVE, SHALL BE FITTED WITH A VALVE DIRECTLY ON THE TANK, CAPABLE OF BEING CLOSED FROM THE OUTSIDE OF THE SPACE. THE QUICK RELEASE VALVE FOR THE EMERGENCY GENERATOR FUEL TANK IS INOPERABLE.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.