MAURY USCG vessel records Sign in
← All vessels

SPIRIT OF 76

SPIRIT OF 76 is a 1976 passenger vessel (inspected). The Coast Guard has recorded 81 inspections since 1985, most recently in August 2023, along with 84 deficiencies, 1 operational control and 2 casualty investigations between 2001 and 2002.

Records from 1985 to 2023. Most recent: inspection, 14 August 2023.

Built
1976
Last inspected
14 August 2023
Documentation
Case Pending · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD2194
140767
Flag
UNITED STATES
367761370
Maury page id
psix-140767

Inspections, by type

…with no type recorded19
Years with a record 33 calendar years (1985–2023)
The 81 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)59.2 ft × 25.1 ft × 7.0 ft
Registered tonnagegross 67 / net 45
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNICHOLS BROTHERS BOAT BUILDERS INC · FREELAND, WA, UNITED STATES · built 1976
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSEATTLE, WA
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationCase Pending · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it45 - Regulatory (Subpart C or D), Net Ton
67 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ2753MMSI 367761370 · active · compulsorily equipped · granted 8 November 2016, expires 8 November 2026
WDB7546MMSI 366943920 · expired · compulsorily equipped · granted 31 January 2014, cancelled 29 June 2024
WDD2194MMSI 367112150 · expired · compulsorily equipped · granted 6 May 2006, cancelled 9 July 2016
WYL4308MMSI not assigned · expired · compulsorily equipped · granted 8 August 1996, cancelled 9 December 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 81

14 August 2023 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7785388
12 October 2022 Construction Oversight · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7572398
17 August 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7536627
3 December 2020 COI Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7104715
10 March 2020 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6924260
23 February 2020 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6922105
22 January 2019 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6613736
13 November 2018 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6574830
16 February 2018 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6360630
9 November 2016 Hull Examination · Internal Structural Exam · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6038297
24 June 2016 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6104585
28 October 2015 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5753012
23 September 2015 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5726077
6 October 2014 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4999892
10 June 2012 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4352528
28 May 2012 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4326003
18 June 2008 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3240817
7 June 2007 Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2954684
12 September 2006 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2776690
26 June 2006 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2693468
26 June 2006 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2695587
1 August 2005 Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2447885
9 March 2005 Construction Oversight
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2323047
14 October 2004 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2220594
1 July 2004 Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2117545
20 April 2004 Annual Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2048299
5 April 2004 Drydock Extension
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2038025
13 February 2004 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2006309
11 February 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2004805
31 December 2003 Security Plan Review - VSP
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2006266
1 April 2003 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1766316
22 March 2002 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1615955
15 March 2002 Internal Structural Exam · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1494804
13 February 2002 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1617723
8 February 2002 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1617705
7 September 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 174913
30 March 2001 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1471423
8 March 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 214028
24 March 2000 Hull Examination · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1361367
9 April 1999 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 788200
19 March 1999 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1410061
13 February 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 9715
16 October 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 79590
1 August 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 223186
2 April 1998 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 788390
19 March 1998 COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1378308
22 July 1997 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 780333
22 April 1997 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1094903
11 April 1997 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1385941
24 June 1996 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1083187
24 May 1996 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1363649
21 May 1996 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 646277
14 May 1996 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 215240
27 March 1996 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1374536
24 March 1995 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1430017
22 July 1994 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1367108
22 June 1994 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1024041
23 May 1994 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1389828
29 March 1994 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1166224
25 May 1993 Re-Inspection · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 830930
6 October 1992 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 643113
6 October 1992 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 643114
27 May 1992 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1134373
22 April 1992 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 949680
23 March 1992 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 943425
11 June 1991 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1315113
30 May 1991 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 907165
29 May 1991 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1221880
24 September 1990 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1213906
14 June 1990 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1228403
29 May 1990 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 917806
7 June 1989 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1200078
22 May 1989 Re-Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1340553
31 October 1988 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1207617
31 May 1988 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1195395
4 June 1987 Hull Examination · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1335810
21 April 1987 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1003980
9 April 1987 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1021863
6 June 1986 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1297335
26 November 1985 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 985659
5 June 1985 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 982433

Deficiency record · 84

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 January 2019 Resolved
Repair main steering gear hydraulic ram and demonstrate system no longer leaks hydraulic fluid. 46 CFR 182.610
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2019
Resolution: Commercial rebuild of faulty actuator, op test sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 January 2019 Resolved
Demonstrate proper operation of fixed bilge pumping system operation in steering compartment. 46 CFR 182.520 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2019
Resolved 28 January 2019
Resolution: Improper valve alignment
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 January 2019 Resolved
Replace broken circuit breaker for bilge alarms in bridge electrical panel. 46 CFR 183.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2019
Resolved 29 January 2019
Resolution: Breaker replaced
Navigation › Piloting/Steering › US Coast Pilot
Issued 16 February 2018 Resolved
Provide updated Coast Pilot VOL 7 exerts for your area of vessel operation.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 February 2018
Resolved 23 February 2018
Navigation › Piloting/Steering › Marine Charts
Issued 16 February 2018 Resolved
Provide update paper chart for your area of vessel operation.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 February 2018
Resolved 23 February 2018
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 16 February 2018 Resolved
Provide proof of servicing for all fire fight equipment onboard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 February 2018
Resolved 23 February 2018
Fire Fighting › Means of Escape › Blocked
Issued 16 February 2018 Resolved
Remove storage wire grading at the starboard side engine room quick acting watertight door. 46 CFR 177.500
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 23 February 2018
Resolved 23 February 2018
Construction/Loadline › Hull › Hull Plating
Issued 18 November 2016 Resolved
Repair holes in transom with steel insert.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 February 2017
Resolved 24 March 2017
Resolution: Replaced holes with new steel circle insert.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 9 November 2016 Resolved
The vessel's Certificate of Inspection expired on June 23, 2016. The vessel continued to operate until November 8, 2016.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2016
Resolution: Vessel issued a new COI on November 18, 2016
Construction/Loadline › Structures › Deck Plating
Issued 9 November 2016 Resolved
Remove silicone and clad weld all holes on the main deck.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 December 2016
Resolved 12 December 2016
Resolution: Owner clad welded all holes in the deck and sent photos of completion.
Electrical › Lighting (service) › Lighting Fixture
Issued 23 September 2015 Resolved
Masthead navigation light inoperable. Repair to satisfaction of attending marine inspector. 46 CFR 183.420
Action required: 705 - Other - as specified
Due 7 October 2015
Resolved 12 October 2015
Resolution: Picture sent of working masthead light.
Lifesaving › Lifefloat › Float Free
Issued 23 September 2015 Resolved
Stow life floats to ensure proper actuation of weak links. 46 CFR 180.137
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 October 2015
Resolved 12 October 2015
Resolution: Picture sent of line for life floats properly installed/coiled in line canisters.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 23 September 2015 Resolved
Life float light inoperable. Repair to satisfaction of attending marine inspector. 46 CFR 180.137
Action required: 705 - Other - as specified
Due 7 October 2015
Resolved 20 October 2015
Resolution: Attending inspector witness proper operation of float light.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 23 September 2015 Resolved
Properly mount fire extinguisher. 46 CFR 181.520
Action required: 705 - Other - as specified
Due 7 October 2015
Resolved 12 October 2015
Resolution: Email sent explaining "extra" fire exinguishers were removed from vessel (no longer laying atop refrigerators unsecured).
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 10 June 2012 Resolved
Provide technician's report attesting to the proper operation of the electrical system for engine controls.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2012
Resolution: Received technician''s report attesting to the satisfactory operation of the electrical system for engine controls.
Construction/Loadline › Hull › Transverse Frame
Issued 7 June 2007 Resolved
Renew skip welds connecting backing plate to transverse frame in forwardmost void.
Due 11 June 2007
Resolved 11 June 2007
Stability › Watertight Integrity › General
Issued 7 June 2007 Resolved
Properly fix stuffing tube between #2 and #3 voids.
Due 11 July 2007
Resolved 18 June 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 26 June 2006 Resolved
Location - Missing
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2006
Resolution: Installed fixed CO2 fire extinguishing system.
Fire Fighting › Fire Pumps › Impeller
Issued 1 August 2005 Resolved
Port engine power take off for the fire pump is not producing flow of fire fighting water.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 September 2005
Resolved 12 August 2005
Resolution: Replaced impeller tested sat.
Engineering › Reduction Gearing/Clutches › Casing
Issued 1 August 2005 Resolved
Shift control cable hold down fasteners for port and starboard engine not securely fastened.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 September 2005
Resolved 12 August 2005
Resolution: Installed wire on shift cable hold downs.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Approval
Issued 1 August 2005 Resolved
Currently there are 4 B-1 fire extinguishers on board. Required to have 1 B-1 and 3 B-II fire extinguishers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 September 2005
Resolved 12 August 2005
Resolution: Replaced 3 B-1 fire extinguishers with 3 B-II fire extinguishers.
Engineering › Bilge Water Management System › Not Installed
Issued 1 August 2005 Resolved
There is no hi bilge alarm installed in lazarette. Install with audible and visual alarms on the brige.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 September 2005
Resolved 19 August 2005
Resolution: Installed bilge hi level alarm in lazarette with audible and visual alarms on the bridge.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 1 August 2005 Resolved
Cutlass bearings inner and outer port and starboard need to be replaced they are more thatn 50% deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 September 2005
Resolved 19 August 2005
Resolution: Replaced inner and outer port and stbd cutlass bearings.
Construction/Loadline › Penetrations › Weld
Issued 1 August 2005 Resolved
#4 void has two pipes penetrating starboard aft watertight bulkhead that is not sealed properly.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 September 2005
Resolved 19 August 2005
Resolution: Installed plate to #4 void pipe penetration for proper seal.
Engineering › Bilge Water Management System › Eductor
Issued 1 August 2005 Resolved
There is no bilge eductor in the lazarette space. Install with remote hi level and alarm to be acknowledged on the bridge.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 September 2005
Resolved 19 August 2005
Resolution: Bilge eductor worked properly.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 20 April 2004 Resolved
Renew port propellor due to excessive wear.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 April 2004
Resolution: Renewed
Construction/Loadline › Structures › Transverse Bulkhead
Issued 20 April 2004 Resolved
Crop and renew buckled section of fwd bulkhead of the tank room stbd side. Insert shall be approx 14 by 24 inches. Coordinate with this office to approve exact scope of the insert and for fitup and final inspection of the repair. LEGACY COMPONENT DESC: Side Shell
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 June 2004
Resolved 23 July 2004
Documentation › Certificates/Documents
Issued 20 April 2004 Resolved
Renew expired Safety Radio Telephone Certificate and provide copy to this office. LEGACY COMPONENT DESC: Safety Radio Telephone Certificate
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2004
Resolved 29 April 2004
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 20 April 2004 Resolved
Permanently secure new, unused tank in tank room stbd side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2004
Resolved 14 May 2004
Personnel › Manning/Qualifications
Issued 20 April 2004 Resolved
Designate in writing the senior deck hand(s) IAW NVIC 01-91.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 May 2004
Resolved 4 May 2004
Fire Fighting › Fire Pumps › Capacity
Issued 20 April 2004 Resolved
Engine driven firepump pressure appeared insufficient during inspection. Repair the engine driven pump and retest to ensure min 60 psi at the pump outlet in accordance with 46CFR181.10-1(c). Electric pump was adequate. LEGACY COMPONENT DESC: Pressure
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 June 2004
Resolved 16 June 2004
Fire Fighting › Fire Main › Condition
Issued 22 March 2002 Resolved
FIX OR REPLACE BROKEN FIRE MAIN ON STBD SIDE IN WAY OF OVERBOARD DISCHARGE
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2002
Resolved 23 March 2002
Resolution: fIRE MAIN REPLACED AND TESTED SAT.
Lifesaving
Issued 30 March 2001 Resolved
IF OPERATING MORE THAN 1 MILE FROM SHORE, VESSEL CANNOT HAVE MORE THAN 125 PERSONS ON BOARD VESSEL.
Condition: Unknown
Due 24 May 2001
Resolved 3 May 2001
Construction/Loadline
Issued 24 March 2000 Resolved
DEMONSTRATE OPERATION OF FIXED BILGE AND HIGH-LEVEL ALARM SYSTEMS IN THE PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 24 April 2000
Resolved 1 May 2000
Electrical
Issued 24 March 2000 Resolved
PROVIDE A DETAILED LINE ITEM DIAGRAM SCHEMATIC OF ENTIRE ELECTRICAL SYSTEM FOR APPROVAL. THIS IS TO INCLUDE SUPPLY, LENGTH OF RUNS, GAUGE OF WIRE USED, AMPS DRAWN, WATTS AND PROTECTION DEVICES/CIRCUIT BREAKERS AS PER 46 CFR 183.340.
Condition: Unknown
Due 6 October 2000
Resolved 18 February 2004
Electrical
Issued 24 March 2000 Resolved
DEMONSTRATE SATISFACTORY INSTALLATION AND OPERATION OF BOTH GENERATORS.
Condition: Unknown
Due 24 April 2000
Resolved 22 April 2000
Electrical
Issued 24 March 2000 Resolved
LINE ALL METAL BATTERY BOXES WITH NON-CONDUCTIVE MATERIAL OR REPLACE.
Condition: Unknown
Due 24 April 2000
Resolved 22 April 2000
Lifesaving
Issued 24 March 2000 Resolved
REMOVE EXCESSIVE OIL FROM BILGE, CLEAN AND PUMP OUT REMAINING OILY/WATER RESIDUE, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 15 April 2000
Resolved 2 May 2000
Electrical
Issued 24 March 2000 Resolved
CLEAN-UP ALL WIRE RUNS UNDERNETH PILOT HOUSE IN WAY OF AIR COMPRESSOR. INSTALL JUNCTION BOX.
Condition: Unknown
Due 24 April 2000
Resolved 1 May 2000
Electrical
Issued 24 March 2000 Resolved
REWIRE OR REMOVE SPEAKER CABLES RUNNING ACROSS DECK IN PILOTHOUSE. CLEAN- UP EXCESS WIRE.
Condition: Unknown
Due 24 April 2000
Resolved 22 April 2000
Construction/Loadline
Issued 24 March 2000 Resolved
CLEAN OUT ANY REMAINING OIL IN BILGES.
Condition: Unknown
Due 24 April 2000
Resolved 1 May 2000
Electrical
Issued 24 March 2000 Resolved
INSTALL BLANKS FOR ALL UNUSED CIRCUIT BREAKERS IN ALL BREAKER PANELS.
Condition: Unknown
Due 24 April 2000
Resolved 22 April 2000
Construction/Loadline
Issued 24 March 2000 Resolved
REMOVE AUTOMATIC BILGE PUMPS AND PIPING IN E/R.
Condition: Unknown
Due 24 April 2000
Resolved 22 April 2000
Fire Fighting
Issued 24 March 2000 Resolved
DEMONSTRATE OPERATION OF MAIN AND AUX FIRE PUMPS IN THE PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 24 April 2000
Resolved 1 May 2000
Engineering
Issued 24 March 2000 Resolved
DEMONSTRATE OPERATION OF BOTH MAIN ENGINES AND TEST PROPULSION CONTROLS IN THE PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 24 April 2000
Resolved 1 May 2000
Fire Fighting
Issued 24 March 2000 Resolved
DEMONSTRATE OPERATION OF ALL INSTALLED FIRE HOSES IN THE PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 24 April 2000
Resolved 1 May 2000
Engineering
Issued 24 March 2000 Resolved
MAKE PERMANENT REPAIRS TO MAIN ENGINE EXHAUST PIPING FLEX JOINTS.
Condition: Unknown
Due 24 April 2000
Resolved 22 April 2000
Engineering
Issued 24 March 2000 Resolved
COVER ALL MAIN ENGINE EXHAUST PIPING WITH APPROPRIATE LAGGING.
Condition: Unknown
Due 24 April 2000
Resolved 22 April 2000
Lifesaving
Issued 24 March 2000 Resolved
PROVIDE PORTABLE LIGHTING AT OPERATING STATION AND ALL ENTERANCES TO E/R. (I.E. BATTLE LANTERNS OR FLASHLIGHTS)
Condition: Unknown
Due 24 April 2000
Resolved 22 April 2000
Fire Fighting
Issued 24 March 2000 Resolved
CONDUCT SATISFACTORY FIRE DRILL IN THE PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 24 April 2000
Resolved 1 May 2000
Electrical
Issued 24 March 2000 Resolved
REPAIR OR REPLACE INOPERABLE BATTERY CHARGER IN E/R.
Condition: Unknown
Due 24 April 2000
Resolved 22 April 2000
Lifesaving
Issued 24 March 2000 Resolved
CONDUCT A SATISFACTORY ABANDON SHIP DRILL WITH A FULL CREW IN THE PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 24 April 2000
Resolved 1 May 2000
Electrical
Issued 24 March 2000 Resolved
REMOVE ALL DEAD-ENDED ELECTRICAL CABLES/WIRING FROM THE VSL.
Condition: Unknown
Due 24 April 2000
Resolved 1 May 2000
Navigation
Issued 24 March 2000 Resolved
TEST STEERING SYSTEM TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 24 April 2000
Resolved 1 May 2000
Lifesaving
Issued 19 March 1999 Resolved
Need to replace all life lines on buoyant apparatus due to deterioration.
Condition: Unknown
Due 19 March 1999
Resolved 19 March 1999
Construction/Loadline
Issued 19 March 1999 Resolved
Need to install proper bilde alarms for all watertight compartments.
Condition: Unknown
Due 19 March 1999
Resolved 19 March 1999
Fire Fighting
Issued 19 March 1999 Resolved
Fire pump not operable.
Condition: Unknown
Due 19 March 1999
Resolved 19 March 1999
Engineering
Issued 19 March 1999 Resolved
Need to provide adequate lagging for port generator exhaust pipping.
Condition: Unknown
Due 19 March 1999
Resolved 19 March 1999
Engineering
Issued 19 March 1999 Resolved
Need to provide adequate rotating machinery guard for electric fire pump.
Condition: Unknown
Due 19 March 1999
Resolved 19 March 1999
Construction/Loadline
Issued 19 March 1998 Resolved
PROVIDE RETAINING DEVICE FOR VOID HATCH COVER AFT OF ENGINE ROOM.
Condition: Unknown
Due 24 March 1998
Resolved 20 March 1998
Navigation
Issued 11 April 1997 Resolved
SECURE PORTSIDE LINKAGE BOLT BTW HYDRAULIC RAM & RUDDER ASSEMBLY WITH LOCKING/PROTECTED NUT.
Condition: Unknown
Due 16 April 1997
Resolved 16 April 1997
Lifesaving
Issued 11 April 1997 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 16 April 1997
Resolved 16 April 1997
Navigation
Issued 11 April 1997 Resolved
POST EMERGENCY RADIO BROADCAST PLACARD IN PILOTHS NEAR RADIO.
Condition: Unknown
Due 15 April 1997
Resolved 16 April 1997
Lifesaving
Issued 11 April 1997 Resolved
REPLACE FRAYED PASSENGER TIE-OFF LANYARDS ON ALL BUOYANT APPARATI.
Condition: Unknown
Due 16 April 1997
Resolved 16 April 1997
Fire Fighting
Issued 11 April 1997 Resolved
B-II FIRE EXTINGUISHER IN ENGIN ROOM WAS NOT MARINE TYPE, COAST GUARD APPROVED.
Condition: Unknown
Due 16 April 1997
Resolved 16 April 1997
Navigation
Issued 24 May 1996 Resolved
COMPASS DEVIATION CARD 20 YEARS OLD. HAVE COMPASS SWUNG AND NEW DEVIATION CARD POSTED ON BRIDGE.
Condition: Unknown
Due 24 May 1996
Resolved 24 May 1996
Documentation
Issued 22 June 1994 Resolved
SUMBIT ELECTRICAL LINE DIAGRAM FOR NEW FIRE PUMP INSTALLATION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 June 1994
Resolved 22 June 1994
Fire Fighting
Issued 22 June 1994 Resolved
MAKE REPAIRS/REPLACE STBD MDE DRIVEN FIRE PUMP.
Condition: Unknown
Due 22 June 1994
Resolved 22 June 1994
Fire Fighting
Issued 23 May 1994 Resolved
REPACK MDE DRIVEN FIRE PUMP SO THAT IT DOES NOT LEAK.
Condition: Unknown
Due 23 June 1994
Resolved 23 June 1994
Engineering
Issued 23 May 1994 Resolved
INSTALL FLAME SCREENS ON BOTH FUEL TANK VENTS. 46 CFR 182.20-25
Condition: Unknown
Due 23 June 1994
Resolved 23 June 1994
Lifesaving
Issued 23 May 1994 Resolved
REINSTALL RING BUOY IN A LOCATION THAT IS READILY ACCESSIBLE TO BOTH THE CREW AND PASSENGERS. 46 CFR 180.30-10
Condition: Unknown
Due 23 June 1994
Resolved 23 June 1994
Engineering
Issued 23 May 1994 Resolved
INSTALL GUARDS FOR ROTATING MACHINERY ON BOTH MDE'S. 46 CFR 177.35-15
Condition: Unknown
Due 23 June 1994
Resolved 23 June 1994
Electrical
Issued 25 May 1993 Resolved
DEMONSTRATE PROPER OPERATION OF GENERATORS AFTER INSTALLATION.
Condition: Unknown
Due 8 June 1993
Resolved 2 June 1993
Electrical
Issued 25 May 1993 Resolved
HARD WIRE ELECTRICAL PUMP TO CAPTIVE AIR WATER TANK FOR MSD.
Condition: Unknown
Due 8 June 1993
Resolved 2 June 1993
Construction/Loadline
Issued 23 March 1992 Resolved
WELD BOTH SIDES OF FORWARD SINK DRAIN WHERE IT PENETRATES THE MAIN DECK._x001C_ DRAIN IS LOCATED IN THE SECOND COMPARTMENT.
Condition: Unknown
Due 23 April 1992
Resolved 23 April 1992
Construction/Loadline
Issued 23 March 1992 Resolved
WELD BOTH SIDES OF OLD TOILET DRAIN ACCESSES WHERE THEY PENETRATE THE MAIN DECK.
Condition: Unknown
Due 23 April 1992
Resolved 23 April 1992
Engineering
Issued 23 March 1992 Resolved
RENEW AFTER PORT STRUT BEARING.
Condition: Unknown
Due 23 April 1992
Resolved 23 April 1992
Accommodation/Occupational Safety
Issued 29 May 1991 Resolved
PROVIDE DOCUMENTARY PROOF THAT THE AIR RECEIVER ON BOARD VESSEL IS CONSTRUCTED IN ACCORDANCE WITH ASME STANDARDS, AND AS PER 46CFR PART 54.
Condition: Unknown
Due 29 May 1991
Resolved 29 May 1991
Engineering
Issued 29 May 1990 Resolved
THE FOLLOWING FUEL LINES ARE TO BE REPLACED WITH MARINE TYPE FLEXIBLE FUEL LINES:(1)STBD ENGINE FUEL RETURN LINE(2)STBD ENGINE FROM FUEL FILTER TO ENGINE(3)PORT ENGINE FUEL RETURN LINE(4)PORT ENGINE LINE FROM FUEL PUMP TO FUEL FILTER(5)PORT ENGINE LINE FROM FUEL FILTER TO ENGINE.
Condition: Unknown
Due 29 May 1990
Resolved 29 May 1990
Electrical
Issued 22 May 1989 Resolved
PROVIDE PROPER FLEX HOSE ASSEMBLY IAW 46CFR182.20-40 TO ALL FLEX HOSE ON BOTH GEN SETS AND PORT MAIN ENGINE. TO BE COMPLETED TO THE SATISIFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 22 May 1989
Resolved 22 May 1989
Electrical
Issued 22 May 1989 Resolved
PROPERLY MOUNT FUEL LINES FRON VALVE ON FWD BULKHEAD IN ENGINE ROOM TO FLEXHOSE CONNECTION ON BOTH GEN SETS IAW 46CFR182.20-40(B)(2). TO BE COMPLETEDTO THE SATISIFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 22 May 1989
Resolved 22 May 1989
Electrical
Issued 22 May 1989 Resolved
PROVIDE MACHINERY GUARD AROUND PULLIES ON STARB. GEN. SET. TO BE COMPLETED TO THE SATISIFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 22 May 1989
Resolved 22 May 1989
Construction/Loadline
Issued 9 April 1987 Resolved
WELD BULKHEAD PENETRATIONS (RUDDER HYDRAULIC PIPE RUNS) IN COMPARTMENT #5 AT BHD #4 STBD SIDE, AND WELD SMALL HOLE (1/4" DIAMETER) JUST TO THE RIGHT OF PIPE RUNS IN SAME BHD AT TOP WELD.
Condition: Unknown
Due 9 April 1987
Resolved 9 April 1987
Construction/Loadline
Issued 9 April 1987 Resolved
DRYDOCK VESSEL. TO BE DONE TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR NOT LATER THAN 09JUN87.
Condition: Unknown
Due 9 April 1987
Resolved 9 April 1987

Casualty record · 2

7 September 2001Routine · role: Involved in a Marine Casualty · activity 174913
8 February 2002Routine · role: Involved in a Marine Casualty · activity 1617705
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record