MAURY USCG vessel records
← All vessels

BRISTOL TRADER

BRISTOL TRADER is a 2016 tank ship. The Coast Guard has recorded 9 inspections since 2016, most recently in September 2025, along with 10 deficiencies and 1 operational control.

Records from 2016 to 2025. Most recent: inspection, 8 September 2025.

Built
2016
Last inspected
8 September 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 September 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9737101
1408935
Flag
PHILIPPINES
Maury page id
psix-1408935

Documentation record

Tonnage as PSIX records it10024 - Convention (Subpart B), Net Ton
35863 - Dead Weight, Metric Ton
44702 - Displacement, Metric Ton
21151 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 9

8 September 2025 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8225281
13 January 2021 PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7122865
9 January 2021 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7118596
15 October 2019 Ballast Water Examination · COC-CHEM & TVE Annual · ISPS II Exam · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6831440
11 October 2018 Deficiency Check · Administrative Inspection · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6559479
25 September 2018 COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6543247
25 September 2018 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6548703
29 September 2017 COC-CHEM & TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6274468
12 August 2016 Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5970648

Deficiency record · 10

01 - Certificates & Documentation › 013 - Documents › P&A manual
Issued 9 January 2021 Resolved
PSCO observed that the approved P&A manual did not incorporate the 2021 amendments to the IBC Code. MARPOL II/14.1
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 February 2021
Resolved 13 January 2021
Resolution: Received, reviewewd and accepted class report attesting to the updates to the P&A Manual.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 9 January 2021 Resolved
PSCO observed that the chief officer lacked basic understanding of the fixed gas detection system and could not calibrate when requested. The C/O could not produce calibration records. Request class attest to the proper operation and valid calibration. SOLAS II-2/4.5.7.3.1
Action required: 15 - Rectify deficiencies by next port
Resolved 13 January 2021
Resolution: Received, reviewed and accepted class report attesting to the [name withheld] familiarity and the proper calibration of the fixed gas detection system.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 9 January 2021 Resolved
PSCO observed that the vessel did not have onboard procedures for calibrating the fixed gas detection system. Request corrective action plan to the satisfaction of the administration. SOLAS IX/3.1 => ISM Code 7
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 February 2021
Resolved 13 January 2021
Resolution: Received, reviewed and accepted RO report attesting to CAP.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 9 January 2021 Resolved
PSCO observed that the approved ODME manual only included a funtion test after installation. Request manual be updated to include testing procedures. MARPOL I/31.4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 February 2021
Resolved 13 January 2021
Resolution: Received, reviewed and acccpeted Class report attesting tot he update to the ODME Manual.
11 - Life Saving Appliances › N/A - No Subsystem › Means of recovery of life saving appliances
Issued 15 October 2019 Resolved
Where davit arms are recovered by power, safety devices shall be fitted which will automatically cut of the power before the davit arms reach the steps in order to prevent over stressing the falls or davits. During the operational test of lowering and raising of the port lifeboat, crew was unable to raise due to electronic means, from a faulty limit switch. SOLAS 74(14 CONS.) III/16 LSA CODE 6.1.2.7
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 15 October 2019
Resolved 15 October 2019
Resolution: Cleared prior to CG team leaving
12 - Dangerous Goods › N/A - No Subsystem › Personal protection
Issued 15 October 2019 Resolved
Personal protection - suitably marked decontamination showers and an eye wash shall be available on deck in convenient locations. PSCO observed operable shower and eyewash station on main deck port manifold. The STBD side eye wash station was located all the way aft at the house. Vessel is restricted to port side operations when loading or discharging cargos with a "yes" listed in column "N" of chapter 17. Until a suitable eyewash and decon shower is fabricated on STBD side manifold or class issues documentation addressing the issue. SOLAS VII/10 IBC 14.3.4
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2019
Resolved 24 October 2019
Resolution: Class report submitted by BV stating the port side eyewash and decon station is sufficient for stbd side protection.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 11 October 2018 Resolved
Unless the cargo tanks are gas free, the master of each tankship to which this subpart applies shall ensure that the inert gas system is operated as necessary to maintain an inert atmosphere in the cargo tanks. Vessel is currently loading ethyl alcohol into a non-inert tank. Ethyl alcohol is a flammable cargo listed in 46CFR30.25-1 and thus must be loaded into an inert tank. *Per 46CFR30.01-5(e)(2), foreign flagged tankships must comply with 46CFR32.53 46CFR32.53-5 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2018
Resolution: O2 content log for tanks 1P, 1S, 5P, 5S, 7P, and 7S showing propert inerting of the cargo tanks containing flammable liquid.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 26 September 2018 Resolved
The safety management system should ensure compliance with mandatory rules and regulations [ISM 1.2.3.1]. The Company should ensure that all personnel involved in the Company's SMS have an adequate understanding of relevant rules, regulations, and codes [ISM 6.4]. Cargo Operation Plan, CO-COPB-08, for ethanol (flashpoint 13°C) discharge in Houston lists "IG or N2 requirements" as "No". According to interview with vessel crew, crew prepared to inert ethanol tanks and sent email to operator on 07SEP2018 requesting if tanks should be inerted. Ooperator replied on 10SEP18 that inerting was not required. As detailed in deficiency #1, on this vessel chemical cargoes with a flashpoint < 60°C must be inerted in order to comply with SOLAS requirements, due to the individual tank washing machine nozzle capacity being >17.5 m3/hr. At time of exam, PSCOs found multiple ethanol cargo tanks at 17-18 % O2 (i.e. not inerted). 74 SOLAS (14) IX/3.1 REF ISM 1.2.3.1 and ISM 6.4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2018
Resolved 23 October 2018
Resolution: Received internal investigation report, safety bulletin from company, and amplifying information via email from technical management company that explain root cause and corrective and preventative actions.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 September 2018 Resolved
The operator of a vessel equipped with ballast water tanks that operates in the waters of the United States must maintain a ballast water management (BWM) plan that has been developed specifically for the vessel and that will allow those responsible for the plan's implementation to understand and follow the vessel's BWM strategy and to comply with the U.S. ballast water requirements. Vessel's ballast water management plan cites out of date 1999 version of U.S. regulations (regulations were changed in 2013) and steats that ballast water exchange (BWE) is still an allowable BWM strategy for this vessel (based on implementation schedule in 33 CFR 151.2035. BWE is NOT an allowable BWM strategy for this vessel). 33 CFR 151.2050 (g) 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2018
Resolved 15 October 2018
Resolution: Received updated Appendix 6 detailing current BWM regulations as they apply to this vessel.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 25 September 2018 Resolved
For tankers of = 20,000 DWT, the protection of cargo tanks shall be achieved by a fixed inert gas system IAW the requirements of the FSS Code. The system shall be operated as to render and maintain the atmosphere of the cargo tanks non-flammable at all times, except when such tanks are gas free. Vessel is 35,86 DWT. Per P & A Manual, vessel is fitted with i40S tank washing machine, nozzle ?15. Each machine is rated at 25 m3/hr, and has 1 nozzle; therefore, individual nozzle capacity is 25 m3/hr (Table B-2 lists 20.2 m3/hr). Therefore, exemption from IG requirements in 4.5.5.2 does not apply as individual nozzle capacity is >17.5 m3/hr. Vessel is currently loaded with ethyl alcohol (10 tanks). Tanks are not inerted. PSCOs witnessed measuring of O2 contentn in tanks and found multiple tanks in flammable range (17-18 % O2). 74 SOLAS (14) II-2/4.5.5 REF 2007 FSS 15.2.1.2 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 September 2018
Resolution: PSCOs re-attended vessel and found all ethanol tanks inerted (vessel's N2 generator was utilized to inert all ethanol tanks. Sampled tanks were at ~1.0 % O2 content).

Ownership record