Professional
The full record for this vessel
Behind this panel: 14 inspections, each with its date, unit and type; 3 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 14
4 November 2025
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8263926
13 September 2025
Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8236709
27 August 2025
PSC B
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8214023
27 June 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8168703
21 November 2023
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7828226
6 July 2022
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7498335
14 June 2019
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6707404
10 December 2018
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6594729
10 August 2018
Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6512883
2 May 2018
PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6399839
5 December 2017
ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6318515
17 April 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6125964
15 November 2016
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6041425
8 February 2016
ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5808025
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 27 August 2025
Resolved
The jacketed piping system shall include a means of collection of leakages and arrangements shall be provided with an alarm in case of fuel line failure. PSCO observed a connection failure at the vessel's main engine oil/fuel drain line leak arrangement causing oil to leak and pool below.
04 SOLAS II-2/4.2.2.5.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 August 2025
Resolved 4 November 2025
Resolution: Received Class report attesting to repairs
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 27 June 2025
Resolved
UNLESS EXPRESSLY PROVIDED OTHERWISE, EVERY SHIP SHALL BE PROVIDED WITH A MAIN STEERING GEAR AND AN AUXILIARY STEERING GEAR TO THE SATISFACTION OF ADMINISTRATION.
PSCO OBSERVED PRIMARY/MAIN STEERING PUMP INOPERABLE DUE TO DAMAGED TRANFORMER IN MOTOR.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 July 2025
Resolution: Received satisfactory class report from BV attesting to repair of the steering gear pump solinoid and transformer.
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 2 May 2018
Resolved
0750-Fire Prevention-In spaces where penetration of oil products is possible, the surface of insulation shall be impervious to oil. Lagging for heater in emergency generator room was saturated with oil. 74SOLAS(01)II-2REG 18.6
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 9 May 2018
Resolved 10 August 2018
Resolution: Vessel Provided Statement Of Fact from Loyds Register verifing that insulation contaminated by oil on thermal oil pipe had been removed and replaced.