Records from 2017 to 2026. Most recent: inspection, 6 June 2026.
Inspection history · 31
6 June 2026
COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8390353
6 December 2025
COC-CVE Quarterly · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8278132
7 June 2025
PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8149669
16 April 2025
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8112650
7 December 2024
COC-CVE Quarterly · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8042714
8 June 2024
COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7927574
16 April 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7896104
9 December 2023
PSC B · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7833136
8 October 2023
In-Service Inspection
Physical examination · Cruise Ship National Center of Expertise · Activity 7819272
10 June 2023
COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7710791
19 April 2023
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7671511
10 December 2022
COC-CVE Quarterly · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7605575
12 October 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7575940
19 June 2022
PSC A · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7481598
21 January 2022
Ballast Water Examination · COC-CVE Quarterly · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7381708
8 November 2021
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7347232
10 October 2021
ISPS Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7329925
8 June 2021
Ballast Water Examination · COC-CVE Annual · ISPS Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7219520
3 April 2020
In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6935053
16 November 2019
COC-CVE Quarterly · PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6856325
15 November 2019
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6859883
18 May 2019
Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6685568
16 November 2018
ISPS III Exam · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6581879
28 September 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6550584
28 August 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6525144
28 August 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6525190
28 August 2018
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6527752
6 July 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6472685
23 May 2018
ISPS II Exam · COC-CVE Initial · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6420796
13 February 2018
COC-CVE Initial · COC-CVE Initial Prep
Administrative · Activities Europe · Activity 6354215
14 November 2017
COC-CVE Initial Prep · COC-CVE Initial
Administrative · Activities Europe · Activity 6306346
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 June 2026
Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures shall be self-closing and be capable of closing with an angle of inclination of up to 3.5 degrees opposing closure. RSD 10.1.05 located in a galley and FSD 12.6.01 located in a stairwell did not shut.
74 SOLAS 20 II-2/9.4.1.1.5.1
17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 June 2026
Resolved 6 June 2026
Resolution: Fire door closed satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 21 January 2022
Resolved
... Means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicator... In passenger ships carrying 36 passengers, the requirements... shall also apply to the crew accommodation areas. PSCO identified corridors in bulkhead deck in which photoluminescent indicator was missing.
SOLAS 20 II-2/13.3.2.5.1
Action required: 10 - Deficiency Rectified
Due 4 February 2022
Resolved 21 January 2022
Resolution: Deficiencies rectified before inspection was completed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 June 2021
Resolved
Double leaf equipped with a latch necessary for their fire integrity shall have a latch that is automatically activated by the operation of doors when released by the system. The closure of a hinged fire door shall be no more than 40 seconds. FSD 4.2.01 closed greater than 40 seconds. FSD 3.2.20, 0.5.11, and 0.5.1.16 sequencing was off not allowing to latch.
74 SOLAS (20) II/2 9.4.1.1.5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2021
Resolved 21 June 2021
Resolution: Vessel sent in class rectification report
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 June 2021
Resolved
Means of escape including stairways shall be marked by lighting or photo luminescent strip indicators. Areas at the bottom of the aft passenger stairway on deck 0 did not have any means of escape lighting or photo luminescent strips.
74 SOLAS (20) II-2 13.2.5.1
Action required: 10 - Deficiency Rectified
Due 18 June 2021
Resolved 18 June 2021