MAURY USCG vessel records
← All vessels

AMASYA

AMASYA is a 2016 tank ship. The Coast Guard has recorded 20 inspections since 2016, most recently in August 2026, along with 7 deficiencies and 2 operational controls.

Records from 2016 to 2026. Most recent: inspection, 7 August 2026.

Built
2016
Last inspected
7 August 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9747326
V7A4084
1411511
Flag
MARSHALL ISLANDS
Maury page id
psix-1411511

Inspections, by type

…with no type recorded4
Years with a record 10 calendar years (2016–2026)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it29557 - Convention (Subpart B), Gross Ton
60699 - Displacement, Metric Ton
49999 - Dead Weight, Metric Ton
13726 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 20

7 August 2026 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8457684
1 April 2025 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8103364
11 March 2025 COC-CHEM & TVE Renew · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8089033
1 January 2025 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8056453
20 November 2024 PSC B · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8037828
10 March 2024 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7875464
7 March 2024 COC-CHEM & TVE Annual
Type not classified · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7875583
7 March 2024 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7875808
28 February 2023 COC-CHEM Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7642879
9 November 2021 Ballast Water Examination · COC-CHEM & TVE Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7346809
20 May 2021 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7207658
26 October 2020 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7081814
24 November 2019 COC-CHEM & TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6861383
16 November 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6856797
13 November 2018 Bulk Liquid Transfer Monitor
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6579886
9 October 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6557857
21 September 2018 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6544940
21 October 2017 Ballast Water Examination · ISPS II Exam · COC-CHEM Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6287108
17 February 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6090220
12 October 2016 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6020675

Deficiency record · 7

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 11 March 2025 Resolved
The conditions of the ship and its equipment shall be maintained to conform with the provisions of the Code. Fixed gas detection system not operating in accordance with manufacturers requirements, and has been repaired/modified without approval.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2025
Resolved 1 April 2025
Resolution: Provided Class survey showing defs has been rectified.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 11 March 2025 Resolved
In meeting these requirements, the company should ensure that appropriate corrective action is taken. Class was not notified of non-conformities. No mitigating procedures were in place to test atmosphere.
Condition: Invalid
Action required: 15 - Rectify deficiencies by next port
Due 11 April 2025
Resolved 1 April 2025
Resolution: Provided class survey showing def has been rectified.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 20 November 2024 Resolved
THE FOLLOWING FIRE PROTECTION SYSTEMS SHALL BE KEPT IN GOOD ORDER SO AS TO ENSURE THEIR REQUIRED PERFORMANCE IF A FIRE ACCURS STRUCTURAL FIRE PROTECTION INCLUDING FIRE RESISTING DIVISIONS AND PROTECTION OF THE OPENING AND PENETRATIONS IN THESE DIVISIONS. PSCO OBSERVED 03 SELF CLOSING FIRE DOORS THAT DID NOT SHUT PROPERLY. ( C DECK CABLE DUCK, ENGINE ROOM MAIN DECK ENTRANCE, AIR CONDITIONING ROOM MAIN DECK) 74 SOLAS (2020) II-2/14 2.1.1.1 17AC
Action required: 17 - Rectify deficiencies prior to departure
Due 21 November 2024
Resolved 22 November 2024
Resolution: Affected doors were repaired and tested, now in good working order.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 20 November 2024 Resolved
LOAD LINE SHALL BE PERMANENTLY MARKED ON THE SIDES OF THE SHIPS TO THE SANTISFATION OF THE ADMINISTRATION. [name withheld] THAT THE PORT SIDE LOAD LINE WAS ONLY PAINTED ON THE SHIP. ILLC 66 (PROTO88) 8 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 November 2024
Resolved 22 November 2024
Resolution: Confirmed that the permanent marking of the load lines had been punched into the ship's sides.
14 - Pollution Prevention › 147 - Anti-Fouling › Other (AFS)
Issued 20 November 2024 Resolved
REMOVING FOULING ORGANISMS FROM VESSEL'S HULL ON A REGULAR BASIS. PSCO OBSERVED A SIGNIFICANT AMOUNT OF AQUATIC GROWTH ON THE PORTSIDE OF THE SHIPS HULL. 33CFR 151.2050(F) 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 November 2024
Resolved 11 December 2024
Resolution: Class survey submitted that def was satisfactorily rectified.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 November 2019 Resolved
MAINTENANCE, TESTING AND INSPECTIONS SHALL BE CARRIED OUT BASED ON GUIDELINES DEVELOPED BY THE ORGANIZATION AND IN A MANNER HAVING DUE REGARD TO ENSURING THE RELIABILITY OF FIRE FIGHTING SYSTEMS AND APPLIANCES. DUE TO THE INOP MAIN FIRE CONTROL PANEL, COULD NOT TEST RELATED FIRE DETECTION SYSTEMS, ACCORDINGLY DETECTION SYSTEM SHALL BE TESTED TO THE SATISFACTION OF CLASS. SOLAS (2014) II-2/2.2.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 24 November 2019
Resolved 25 November 2019
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 24 November 2019 Resolved
IN ORDER TO ACHIEVE THE FIRE SAFETY OBJECTIVES SERT OUT IN PARAGRAPH 1, THE FUNCTIONAL REQUIREMENTS ARE EMBODIED IN THE REGULATIONS OF THIS CHAPTER AS APPROPRIATE: DETECTION OF ANY FIRE IN THE ZONE OF ORIGIN. THE MAIN FIRE CONTROL PANEL IS INOPERATIVE. CONDUCT REPAIR TO SATISFACTION OF CLASS. SOLAS (2014) II-2/2.2.1.4
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 24 November 2019
Resolved 25 November 2019

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.