MAURY USCG vessel records Sign in
← All vessels

DAVID J. BANGERT

DAVID J. BANGERT is a 2016 towing vessel. The Coast Guard has recorded 10 inspections since 2016, most recently in April 2026, along with 15 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 22 April 2026.

Built
2016
Last inspected
22 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI9779
1411550
Flag
UNITED STATES
367752060
Maury page id
psix-1411550

Inspections, by type

Years with a record 9 calendar years (2016–2026)
The 10 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)55.0 ft × 24.0 ft × 8.0 ft
Registered tonnagegross 70 / net 56
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBARBOUR JB SHIPYARD LLC · ST LOUIS · built 2016
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 2 October 2025 · expires 31 October 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it56 - Simplified, Net Ton
70 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI9779MMSI 367752060 · active · compulsorily equipped · granted 4 June 2026, expires 24 August 2036
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 10

22 April 2026 Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8353027
3 June 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8150328
23 February 2024 COI Inspection · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7869301
6 June 2023 Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7704819
16 March 2022 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7412913
20 July 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7262447
30 July 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7019851
23 January 2019 Initial Certification · Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6626036
1 September 2016 Deficiency Check · Industry Initiated Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5989901
7 March 2016 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5994236

Deficiency record · 15

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 May 2022 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. The steering gear is hitting the port rudder stop.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2022
Resolved 12 May 2022
Resolution: Received photographic evidence sufficient to clear deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 20 July 2021 Resolved
Lifebuoy on main deck has degraded lifeline and attaching lanyard for floating electric water light. Prove to the Coast Guard Marine Inspector that the lifeline and attaching lanyard are serviceable and meet required lengths/types.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2021
Resolved 21 July 2021
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 July 2021 Resolved
Port rudder ram hydraulic hose drags the deck and has severe degradation, which exposed metal mesh reinforcement. Recommend removal and renewal of hydraulic hose. Prove to the Coast Guard Marine Inspector that the hose no longer drags across the deck and has no wear spots.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2021
Resolved 27 July 2021
Resolution: Cleared to the satisfaction of the attending Coast Guard marine inspector.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 10 August 2020 Resolved
Port side fuel shutoff not operating correctly (wire broke). Prove proper operation of fuel shutoff to the satisfaction of the Coast Guard Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 August 2020
Resolution: Cleared to the satisfaction of the CG marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 May 2019 Resolved
Add one 40B portable fire extinguisher in vicinity of flammable stores locker.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 25 June 2019
Resolution: Fire extinguisher mounted near flammable locker
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 May 2019 Resolved
Ensure documentation of Safety Orientation in TVR includes date(s) of training; description of training or orientation topic; name and signature of individual(s) providing training or orientation; and name and signature of individual receiving training or orientation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 25 June 2019
Resolution: Documentation provided to include missing information.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 May 2019 Resolved
Ensure documentation of monthly fire drill includes a brief description in addition to date and participants.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 25 June 2019
Resolution: Provided documentation of monthly fire drill with required information.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 May 2019 Resolved
Provide appropriate documentation of all required tests with the frequency required in table 143.245(b).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 25 June 2019
Resolution: Provided documentation of logbook entries for required tests.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 29 May 2019 Resolved
Provide means to close port and starboard engine room ventilation ducts.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 25 June 2019
Resolution: Stripping added to ventilation covers to seal gap previously noted.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 29 May 2019 Resolved
Demonstrate to attending CG Marine Inspector that the following alarms and set points meet the performance criteria in stated site: main engine low lube oil pressure, main engine high cooling water temperature, generator low lube oil pressure, generator high cooling water temperature.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 17 July 2019
Resolution: Demonstrated proof of audible and visual alarms at set points for generators and engines at operating station.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 29 May 2019 Resolved
Install and demonstrate that the low hydraulic steering fluid level alarm meets the performance criteria in stated cite.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 17 July 2019
Resolution: Provided proof of audible and visual alarm for low hydraulic steering fluid at operating station.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 29 May 2019 Resolved
Ensure the Safety Orientation Training for new crew members includes "Prevention of Falls Overboard" and "How to respond to emergencies relative to tow."
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 25 June 2019
Resolution: Dcoumentation provided for providing training for items missing
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 29 May 2019 Resolved
Establish procedures addressing fall overboard prevention and recovery of persons from water to include at a minimum the requirements outlined in 46 CFR 140.425
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 25 June 2019
Resolution: Provided documentation establishing Fall Overboard Prevention
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 May 2019 Resolved
Work vests were found stored with Type I PFDs. Ensure work vests are stored.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 25 June 2019
Resolution: Work vest removed from locker and sticker placed on locker to indicate "Lifevests Only"
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 29 May 2019 Resolved
Provide documentation of monthly lifesaving equipment inspections to include number and type of equipment; date inspection conducted; name of person conducting inspection; and result of inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 25 June 2019
Resolution: Provided record of monthly inspection for lifesaving equipment and logbook where information will be recorded.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.