Records from 2016 to 2026. Most recent: inspection, 16 January 2026.
Documentation record
Registered dimensions (L × B × D)41.5 ft × 14.2 ft × 6.3 ft
Registered tonnagegross 27 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA MARINE INDUSTRIES · SEATTLE, WA, UNITED STATES · built 1976
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORT OF ILWACO, WA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 15 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it27 - Regulatory (Subpart C or D), Gross Ton
18 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
16 January 2026
DAPI Audit · Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8297606
11 September 2025
Examination of Repairs
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8231806
31 January 2025
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8073029
14 January 2025
Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8063656
28 March 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7886331
28 March 2023
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7658364
22 March 2023
Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7654973
8 April 2022
COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7426928
4 July 2021
Type not recorded
No type recorded · USCGC ORCAS (WPB 1327) · USCG Northwest District (CGD-NW) · Activity 7255455
16 April 2021
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7182642
16 April 2021
Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7182650
3 August 2020
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7024103
13 December 2019
Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6874955
4 September 2019
Examination of Repairs
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6889206
19 April 2019
Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6665636
15 December 2018
Type not recorded
No type recorded · Station Cape Disappointment · USCG Northwest District (CGD-NW) · Activity 6598367
13 April 2018
Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6390592
7 April 2017
Deficiency Check · Hull Examination · DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6121304
25 March 2016
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5840630
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 March 2024
Resolved
Vessel must have an interconnected fire detection system in compliance with 46 CFR 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation and machinery spaces. The cabin fire detector had sensor failure and did not function properly. Repair or replace the fire detection unit. 46 CFR 181.405(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2024
Resolved 28 March 2024
Resolution: Fire detection unit was reset and demonstrated functioning properly.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 28 March 2023
Resolved
Lazarette bilge high water alarm inoperable. A visual & audible alarm must be provided at the operating station to indicate a high water level. Repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2023
Resolved 3 April 2023
Resolution: Bilge high water alarm float switch replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 March 2023
Resolved
Engine room bilge suction is missing strainer & several inches of hose. A bilge suction must be fitted with a suitable strainer having an open area not less than 3 times the area of the bilge pipe.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2023
Resolved 3 April 2023
Resolution: New engine room bilge strainer installed.
Engineering › Bilge Water Management System › Not Operational
Issued 18 April 2017
Resolved
Bilge suction in storage space inop.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2017
Resolution: Verified proper operation of bilge suction in storage space.
Engineering › Bilge Water Management System › Valve
Issued 18 April 2017
Resolved
Missing positive control valves in dedicated bilge discharge lines.
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 25 April 2017
Resolution: 06 new skin valves installed in bilge discharge lines.
Communications › Radio Communications › EPIRB
Issued 7 April 2017
Resolved
Replace expired battery.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2017
Resolution: Verified new battery in EPIRB.