SALTY DOG

SALTY DOG is a 1976 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 2016, most recently in January 2026, along with 6 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 16 January 2026.

Built
1976
Last inspected
16 January 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 January 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDB2360
141288
Flag
UNITED STATES
Maury page id
psix-141288

Documentation record

Registered dimensions (L × B × D)41.5 ft × 14.2 ft × 6.3 ft
Registered tonnagegross 27 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA MARINE INDUSTRIES · SEATTLE, WA, UNITED STATES · built 1976
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORT OF ILWACO, WA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 15 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it27 - Regulatory (Subpart C or D), Gross Ton
18 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 19

16 January 2026 DAPI Audit · Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8297606
11 September 2025 Examination of Repairs
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8231806
31 January 2025 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8073029
14 January 2025 Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8063656
28 March 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7886331
28 March 2023 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7658364
22 March 2023 Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7654973
8 April 2022 COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7426928
4 July 2021 Type not recorded
No type recorded · USCGC ORCAS (WPB 1327) · USCG Northwest District (CGD-NW) · Activity 7255455
16 April 2021 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7182642
16 April 2021 Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7182650
3 August 2020 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7024103
13 December 2019 Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6874955
4 September 2019 Examination of Repairs
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6889206
19 April 2019 Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6665636
15 December 2018 Type not recorded
No type recorded · Station Cape Disappointment · USCG Northwest District (CGD-NW) · Activity 6598367
13 April 2018 Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6390592
7 April 2017 Deficiency Check · Hull Examination · DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6121304
25 March 2016 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5840630

Deficiency record · 6

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 March 2024 Resolved
Vessel must have an interconnected fire detection system in compliance with 46 CFR 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation and machinery spaces. The cabin fire detector had sensor failure and did not function properly. Repair or replace the fire detection unit. 46 CFR 181.405(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2024
Resolved 28 March 2024
Resolution: Fire detection unit was reset and demonstrated functioning properly.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 28 March 2023 Resolved
Lazarette bilge high water alarm inoperable. A visual & audible alarm must be provided at the operating station to indicate a high water level. Repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2023
Resolved 3 April 2023
Resolution: Bilge high water alarm float switch replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 March 2023 Resolved
Engine room bilge suction is missing strainer & several inches of hose. A bilge suction must be fitted with a suitable strainer having an open area not less than 3 times the area of the bilge pipe.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2023
Resolved 3 April 2023
Resolution: New engine room bilge strainer installed.
Engineering › Bilge Water Management System › Not Operational
Issued 18 April 2017 Resolved
Bilge suction in storage space inop.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2017
Resolution: Verified proper operation of bilge suction in storage space.
Engineering › Bilge Water Management System › Valve
Issued 18 April 2017 Resolved
Missing positive control valves in dedicated bilge discharge lines.
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 25 April 2017
Resolution: 06 new skin valves installed in bilge discharge lines.
Communications › Radio Communications › EPIRB
Issued 7 April 2017 Resolved
Replace expired battery.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2017
Resolution: Verified new battery in EPIRB.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.