MAURY USCG vessel records
← All vessels

CAYUGA KRAKEN

CAYUGA KRAKEN is a 2016 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 2016, most recently in May 2026, along with 35 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 26 May 2026.

Built
2016
Last inspected
26 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 May 2026
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1415609
Flag
UNITED STATES
Maury page id
psix-1415609

Documentation record

Tonnage as PSIX records it2 - Simplified, Gross Ton
2 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 19

26 May 2026 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8381013
21 May 2025 Internal Structural Exam · COI Inspection · Drydock Exam · Hull Examination · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8120178
14 January 2025 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8063389
21 November 2024 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8037999
16 October 2023 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7795331
12 October 2022 Drydock Exam · DAPI Audit · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7542537
7 October 2020 Deficiency Check · Annual Inspection · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7067000
22 October 2019 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6841933
4 March 2019 In-Service Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6636119
20 December 2018 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6600993
30 November 2018 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6580747
26 November 2018 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6586928
5 October 2018 Examination of Repairs · Drydock Exam · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6555709
23 March 2018 Administrative Inspection · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6377213
23 March 2018 Simplified Stability Test
Physical examination · Marine Safety Center (MSC) · Activity 6378978
1 March 2018 Plan Review "T" Boat · Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6368191
5 October 2017 Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6282093
23 August 2016 Initial Certification · Deficiency Check · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5980627
22 August 2016 Construction Oversight · Initial Certification
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5980261

Deficiency record · 35

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 May 2026 Resolved
Life Jackets missing new vessel name.
Action required: 10 - Deficiency Rectified
Due 8 June 2026
Resolved 8 June 2026
Resolution: Correct on the spot
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 21 May 2025 Resolved
A drydock examination...must be conducted while the vessel is hauled out...During the examination all accessible parts of the vessel's underwater body...shall be made available for examination. Several bolts on the steering and engine components were rusted. 46 CFR 176.610 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 2 June 2025
Resolution: Received picture of newly installed bolts.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 21 May 2025 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Fuel shut offs were not labeled. 46 CFR 185.608
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 2 June 2025
Resolution: Received picture of label.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 May 2025 Resolved
All cable and wire must be installed with metal supports spaced not more than 610 millimeters (24 inches) apart. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support. Zip ties were used as cable supports. 46 CFR 183.340(b)(3)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 2 June 2025
Resolution: Received picture of metal wire supports.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 May 2025 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Child and adult life jackets were not separated adequately. 46 CFR 180.78 (a) (5)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 2 June 2025
Resolution: Recieved picture of child life jackets separated in labeled bag.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 May 2025 Resolved
Each ring life buoy must be marked with Type II retroreflective material. Ring life buoy did not have retroflective tape. 46 CFR 185.604(i)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 12 June 2025
Resolution: Received photos of retrorelective tape added to life ring, see documents tab.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 May 2025 Resolved
Each life jacket and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Ring life buoy and one life jacket were not labeled with vessel name. 46 CFR 185.606 (b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 2 June 2025
Resolution: Photos of labeling sent.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 November 2024 Resolved
The owner or managing operator shall make a vessel available for drydock examinations, internal structural examinations, and underwater surveys (UWILD) required by this section. Vessel did not perform its drydock/internal structural exam prior to its due date of 31OCT24. Vessel is prohibited from carrying passengers until a drydock and internal structural exam can be completed to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 January 2025
Resolution: COI was revoked due to being unable to get in contact with O/O. Vessel has NOT completed DDE/ISE.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 16 October 2023 Resolved
...no vessel may be navigated unless it has in its service and onboard the crew complement required by the COI. Vessel did not have correct number of crew required by Certificate of Inspection, therefore, vessel was unable able perform drills as part of annual inspection. Reschedule to perform drills when properly manned.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2023
Resolved 23 October 2023
Resolution: Def Check completed. Man Overboard and Fire Drill completed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 October 2020 Resolved
The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by Table 181.500(b). Vessel has no 40-B:C extinguisher on board. Install 40-B:C extinguisher.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2020
Resolved 21 October 2020
Resolution: 40-B.C installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 October 2020 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel. Numerous dead-end wires thoughout vessel and on battery terminals. remove or properly protect dead-end wires.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2020
Resolved 4 November 2020
Resolution: Master provided photo evidence of proper battery instalation.
09 - Working and Living Conditions › 092 - Working Conditions › Gas instruments
Issued 7 October 2020 Resolved
Portable tanks must meet the requirements of ABYC H-25. Vessel has a spare fuel tank on board which exeeds the quantity limit. Remove spare fuel tank.
Action required: 10 - Deficiency Rectified
Due 6 November 2020
Resolved 7 October 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 October 2020 Resolved
At least one ring life buoy must be fitted with a lifeline. Ring life buoy has no lifeline. Add lifeline.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2020
Resolved 21 October 2020
Resolution: lifeline added to ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 October 2020 Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material. Ring life buoy has no retro reflective tape material. Add proper Amount.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2020
Resolved 4 November 2020
Resolution: Retroreflective tape installed.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 7 October 2020 Resolved
A vessel must be fitted with ground tackle cognizant [name withheld] shackle connecting line to the vessel is wasted. Replaced shackle.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2020
Resolved 21 October 2020
Resolution: Master removed wasted shackle.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 7 October 2020 Resolved
Emergency instructions must be mounted at the operating station.Vessel has no heavy wheather instructions. Post instructions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2020
Resolved 4 November 2020
Resolution: Heavy wheather instructions posted.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 7 October 2020 Resolved
A vessel must carry adequate and up-to-date charts, and publications. Missing charts, Light list, Tides/Currents and Coast pilot. Add publication.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2020
Resolved 21 October 2020
Resolution: Master provided independent electronic charts and pubs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 October 2019 Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Vessel could not provide documented pre-employment testing results.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 3 December 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 October 2019 Resolved
A vessel not required to have a power driven fire pump must have at least 3 2.5 gallon buckets, with an attached lanyard satisfactory to the OCMI placed so as to be easily available during an emergency. Fire buckets were not the proper size. Replace with proper buckets.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 6 December 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 October 2019 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets. Child life jackets were stored with adult life jackets. Move child life jackets into separate storage and properly label.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 3 December 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 October 2019 Resolved
Each life buoy must be marked in clearly legible black capital letters with the vessel's name. Vessel's name was not legible. Re-stencil vessel's name.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 3 December 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 October 2019 Resolved
Each floating waterlight must have a lanyard of at least 3 ft in length, but not more than 6 ft in length, securing the waterlight around the body of the ring life buoy. Lanyard was not of a floating material. Replace lanyard.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 3 December 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 October 2019 Resolved
Each battery used in an item of lifesaving equipment must be replaced during the annual inspection if the expiration date of the battery was passed. Waterlight battery was expired. Replace battery.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 3 December 2019
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 30 October 2019 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at operating station, emergency instructions containing the actions to be taken in the ecent of fire, heavy weather, or man overboard conditions. Vessel does not have emergency instructions mounted. Post emergency instructions.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 3 December 2019
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 30 October 2019 Resolved
A vessel must carry a first aid kit approved under 46CFR160.041. First aid kit had several expired items. Replace first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 3 December 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 December 2018 Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. Fire extinguishers were stored with lifejackets with no mounting. Permanently mount 40-B:C extinguisher near outboard engines, 10-B:C extinguisher near operating station, and 2-A extinguisher in passenger accommodation space. - 46CFR181.520
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2018
Resolution: Vessel representative used stainless steel hose clamps with factory mounts for fire extinguishers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 December 2018 Resolved
Ring life buoy must be fitted with a lifeline that is buoyant, of at least 60 feet in length, non-kinking, have a diameter of at least 5/16 inch, have a breaking strength of at least 1,124 pounds, and be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. Lifeline installed does not meet the specifications listed above. Replace. - 46CFR180.70(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2018
Resolved 7 December 2018
Resolution: Vessel representative replaced lifeline with buoyant 70' "throw rope" with bag to prevent deterioration from UV light.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 December 2018 Resolved
Each floating waterlight must be attached to the lanyard with a corrosion resistant clip. No clip installed. Provide. - 46CFR180.70(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2018
Resolved 7 December 2018
Resolution: Vessel representative installed corrosion resistant clip.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 December 2018 Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel’s name. No markings on buoy. Mark. - 46CFR185.604(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2018
Resolved 7 December 2018
Resolution: Vessel representative marked buoy with vessel's name.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 December 2018 Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least 0.5 inches high: ‘‘DISTRESS SIGNALS’’. No required markings on container. Mark. - 46CFR185.614
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2018
Resolved 7 December 2018
Resolution: Vessel representative marked container.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 December 2018 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Multiple expired items in first-aid kit contents. Replace items or kit. - 46CFR184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2018
Resolved 11 December 2018
Resolution: Vessel representative replaced expired asprin.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 December 2018 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Starboard sidelight is inoperable. Repair. - 46CFR183.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2018
Resolved 7 December 2018
Resolution: Vessel representative replaced sidelight bulb. Tested operation, all sat.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 5 October 2017 Resolved
Perform annual servicing on all Fire extinguishers IAW 46 CFR 176.810.
Action required: 705 - Other - as specified
Due 21 October 2017
Resolved 16 October 2017
Resolution: Serviced all extinguishers.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 October 2017 Resolved
Prove proper operation of port navigation light. Vessel may not operate during restricted visibility until deficiency is cleared IAW 46 CFR 183.420.
Action required: 705 - Other - as specified
Due 21 October 2017
Resolved 16 October 2017
Resolution: Replaced navigation light.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 4 October 2016 Resolved
COMPLETE A NEW TO ZONE INSPECTION AND THE ATTACHED WORKLIST DATED 04 OCT 2016 TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO THE CARRIAGE OF PASSENGERS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2016
Resolved 31 October 2016
Resolution: COMPLETED SATISFACTORY NEW TO ZONE ICOI.

Ownership record