MAURY USCG vessel records Sign in
← All vessels

HT LIBERTY

HT LIBERTY is a 2000 passenger vessel (inspected). The Coast Guard has recorded 33 inspections since 2000, most recently in May 2021, along with 88 deficiencies — 1 with no resolution recorded —, 1 operational control, 1 with no removal date recorded and 4 casualty investigations between 2005 and 2006.

Records from 2000 to 2021. Most recent: inspection, 25 May 2021.

Built
2000
Last inspected
25 May 2021
Documentation
Expired · documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

WDD4688
Flag
UNITED STATES
366790960, 367148070, 367598840 (licence lapsed)
Maury page id
psix-14175

Inspections, by type

…with no type recorded8
…past their stated due date1
Years with a record 14 calendar years (2000–2021)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)38.0 ft × 8.5 ft × 5.0 ft
Registered tonnagegross 10 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOOL AMPHIBIOUS MFG INST · SOUTH LIMA, NY, UNITED STATES · built 2000
Hull materialAluminum
PropulsionDiesel Outdrive
Hull shapeShip
Hull configurationMonohull
Hailing portBRANSON, MO
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Simplified, Net Ton
10 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH2556MMSI 367598840 · expired · voluntarily equipped · granted 17 December 2013, cancelled 17 February 2024
WDD4688MMSI 367148070 · expired · voluntarily equipped · granted 31 October 2006, cancelled 31 December 2016
WDA2765MMSI 366790960 · expired · voluntarily equipped · granted 30 October 2000, cancelled 1 January 2011
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 33

25 May 2021 Administrative Inspection · Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7250807
20 January 2017 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6073885
28 December 2015 Annual Inspection · Drydock Exam · Internal Structural Exam · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5791278
1 February 2012 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4235854
14 February 2011 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3944699
7 December 2009 Deficiency Check · DAPI Audit · Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3645708
11 December 2008 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3376291
5 October 2006 COI Inspection · Hull Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2791586
26 September 2006 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2786989
25 May 2006 Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2658797
24 May 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2666371
29 March 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2655529
18 February 2006 Damage Survey · Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2587813
26 September 2005 In-Service Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2500155
11 July 2005 In-Service Inspection · COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2422834
3 May 2005 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2348182
11 February 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2290646
9 February 2005 Damage Survey · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2290514
14 January 2005 Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2275206
13 January 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2356091
16 November 2004 Deficiency Check · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2241790
14 October 2004 Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2223307
26 September 2004 Annual Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2206510
22 July 2004 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2141691
4 May 2004 Type not recorded
No type recorded · GROUP CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2059104
18 September 2003 Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1907915
22 January 2003 Administrative Inspection
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1733537
7 January 2002 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1476203
10 September 2001 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1436624
10 May 2001 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1064389
28 September 2000 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1441741
1 September 2000 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1072658
1 September 2000 Hull Examination · COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1456887

Deficiency record · 88

Lifesaving › Lifejacket/PFD (General) › Condition
Issued 28 December 2015 Resolved
Provide new adult PFD's tp replace 33 unserviceable identified.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 December 2015
Lifesaving › Lifebuoys › Serviceable
Issued 28 December 2015 Resolved
Renew lifering
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 December 2015
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 28 December 2015 Resolved
Service all fire extinguishers
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 December 2015
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 28 December 2015 Resolved
Renew PFD donning placard
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 December 2015
Resolution: Renew PFD donning placard
Construction/Loadline › Hull › Bottom Plating
Issued 28 December 2015 No resolution recorded
Provide a plan to address pitting on the outside of the vessels bottom plate. The vessels bottom will need to be media blasted and made availible for inspection.
Condition: Improper/Lack of Maintenance
Due 28 January 2016 — due date passed with no resolution recorded
Navigation › Piloting/Steering › Coast Guard Light List
Issued 14 February 2011 Resolved
Provide updated light list.
Action required: 705 - Other - as specified
Due 16 February 2011
Resolved 14 February 2011
Navigation › Piloting/Steering › US Coast Pilot
Issued 14 February 2011 Resolved
Provide updated Coast Pilot.
Action required: 705 - Other - as specified
Due 16 February 2011
Resolved 14 February 2011
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 14 February 2011 Resolved
Provide updated tide and current tables.
Action required: 705 - Other - as specified
Due 16 February 2011
Resolved 14 February 2011
Navigation › Piloting/Steering › Marine Charts
Issued 14 February 2011 Resolved
Provide updated marine charts.
Action required: 705 - Other - as specified
Due 16 February 2011
Resolved 14 February 2011
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 14 February 2011 Resolved
Provide one adult type 1 life jacket.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2011
Engineering › Fuel Oil Service System › Valve
Issued 14 February 2011 Resolved
Prove proper operation of emergency shut-off valve.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 February 2011
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 February 2011 Resolved
Replace expired items in first aid kit.
Action required: 705 - Other - as specified
Due 16 February 2011
Resolved 14 February 2011
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 14 February 2011 Resolved
Provide list of employees enrolled in drug consortium program.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2011
Construction/Loadline › Hull › Bottom Plating
Issued 7 December 2009 Resolved
Sand/Grind back corrosion IWO welds on exterior hull both p/s side and make available for USCG inspector.
Action required: 705 - Other - as specified
Due 21 December 2009
Resolved 10 December 2009
Stability › Watertight Integrity › General
Issued 7 December 2009 Resolved
Make aft hatch on main deck available for USCG inspector access.
Action required: 705 - Other - as specified
Due 21 December 2009
Resolved 10 December 2009
Stability › Watertight Integrity › Weathertight Enclosure
Issued 7 December 2009 Resolved
Provide gasket material on both FWD STBD and CTR port watertight doors to make doors watertight again.
Action required: 705 - Other - as specified
Due 21 December 2009
Resolved 10 December 2009
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 11 December 2008 Resolved
Provide one additional lifejacket IAW COI prior to carrying 47 persons onboard. Only 43 passengers allowed on vessel.
Action required: 705 - Other - as specified
Due 18 December 2008
Resolved 18 December 2008
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 11 December 2008 Resolved
Re-label ring buoy.
Action required: 705 - Other - as specified
Due 18 December 2008
Resolved 18 December 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 December 2008 Resolved
Remove dead-end wires both port and STBD side just fwd of engine cooling radiator.
Action required: 705 - Other - as specified
Due 18 December 2008
Resolved 18 December 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 December 2008 Resolved
Replace bear wire in way of engine air filter on port side.
Action required: 705 - Other - as specified
Due 18 December 2008
Resolved 18 December 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 December 2008 Resolved
Provide electrical plan with newly added electrical shutdown switch.
Action required: 705 - Other - as specified
Due 18 December 2008
Resolved 18 December 2008
Engineering › Bilge Water Management System › Not Operational
Issued 11 December 2008 Resolved
Show proper operation of electric submersible pump, prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2008
Operations/Management › Drills/Instruction › Not Conducted
Issued 11 December 2008 Resolved
Conduct fire and man overboard in the presents of a USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 18 December 2008
Resolved 18 December 2008
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 11 December 2008 Resolved
Provide bonding wire for fuel fill and tank.
Action required: 705 - Other - as specified
Due 18 December 2008
Resolved 18 December 2008
Communications › Radio Communications › EPIRB
Issued 5 October 2006 Resolved
Relocate the EPIRB to a float free position, or remove the EPIRB from the vessel.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 October 2006 Resolved
Remove all loose electrical wiring in the bilge. Properly dead-end any unused wiring.
Condition: Improper/Lack of Maintenance
Due 20 October 2006
Resolved 16 August 2007
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 5 October 2006 Resolved
Provide valid CPR and First Aid course completion cards for a minimum of 50% of the vessel crew.
Condition: Unknown
Due 20 October 2006
Resolved 17 August 2007
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 5 October 2006 Resolved
Provide proof of enrollment in a drug testing consortium, or provide written drug and alcohol program in accordance with 46 CFR Part 16.
Due 20 October 2006
Resolved 16 August 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 October 2006 Resolved
Properly locate the combination running light fixture to be level with the deck plane.
Condition: Improper Installation
Due 30 October 2006
Resolved 17 August 2007
Engineering › Steering Gear System › Linkage
Issued 5 October 2006 Resolved
Provide external protection for the steering gear cable to prevent wear in way of the radiator casing.
Condition: Improper Installation
Due 5 November 2006
Resolved 3 January 2008
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 5 October 2006 Resolved
Renew the cracked windshield.
Due 5 November 2006
Resolved 3 January 2008
Documentation › Certificates/Documents › FCC SSL
Issued 5 October 2006 Resolved
Update the vessel FCC Station License to reflect the new owner.
Due 5 November 2006
Resolved 16 August 2007
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 5 October 2006 Resolved
Properly repair the loose deck coating to prevent a trip hazard.
Condition: Improper/Lack of Maintenance
Due 5 November 2006
Resolved 3 January 2008
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 5 October 2006 Resolved
Provide written emergency response plan in accordance with NVIC 1-01.
Due 5 November 2006
Resolved 16 August 2007
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 25 May 2006 Resolved
Air actuated drive selector ram failed while underway. The ram selects either outdrive or road wheels.
Due 25 May 2006
Resolved 25 May 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 July 2005 Resolved
Remove or repair hanging wiring by driver's door.
Condition: Improper Installation
Due 13 July 2005
Resolved 11 July 2005
Resolution: Wiring removed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 July 2005 Resolved
Replace bulb in fwd nav. light
Condition: Improper/Lack of Maintenance
Due 13 July 2005
Resolved 11 July 2005
Resolution: Bulb replaced
Fire Fighting › Fire Bucket › Stenciling
Issued 11 July 2005 Resolved
Label Fire buckets/ attach proper length lanyards.
Condition: Improper/Lack of Maintenance
Due 13 July 2005
Resolved 11 July 2005
Resolution: Stenciled Fire Bucket/ replaced lanyards
Documentation › Markings/Placards › Lifejacket Placard
Issued 11 July 2005 Resolved
Provide sufficient number of lifejacket donning placards.
Condition: Improper/Lack of Maintenance
Due 13 July 2005
Resolved 11 July 2005
Resolution: Posted lifejacket donning placards.
Lifesaving › Lifefloat › Retroreflective Material
Issued 11 July 2005 Resolved
Provide new reflective tape for lifering.
Condition: Improper/Lack of Maintenance
Due 13 July 2005
Resolved 11 July 2005
Resolution: replaced reflective tape on lifering.
Deck/Cargo › Mooring/Anchoring › Anchor Shackle
Issued 11 July 2005 Resolved
Safety wire anchor clevice.
Condition: Improper Installation
Due 13 July 2005
Resolved 11 July 2005
Resolution: Provided stainless steel wire.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 11 July 2005 Resolved
Hydrostatic release is expired.
Condition: Unknown
Due 13 July 2005
Resolved 11 July 2005
Resolution: Replaced Hydrostat.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 11 July 2005 Resolved
Repair exhaust lagging near support bearing.
Condition: Improper Installation
Due 13 July 2005
Resolved 11 July 2005
Resolution: Replaced exhaust lagging.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 11 July 2005 Resolved
Provide non-combustible waste receptacles.
Condition: Unknown
Due 13 July 2005
Resolved 11 July 2005
Resolution: new non-combustible waste receptacles.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 11 July 2005 Resolved
Provide 30mil flame screen for fuel vents.
Condition: Improper Installation
Due 13 July 2005
Resolved 11 July 2005
Resolution: Provided flame screens.
Engineering › Bilge Water Management System › Pump
Issued 11 July 2005 Resolved
Provide proper operation of bilge pump.
Condition: Unknown
Due 13 July 2005
Resolved 11 July 2005
Resolution: Replaced bilge pump.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 July 2005 Resolved
Provide non-corrosive clip for lifering to lifering light.
Condition: Unknown
Due 13 July 2005
Resolved 11 July 2005
Resolution: Installed non-corrosive clip to lifering light.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 9 February 2005 Resolved
Make proper repairs to vessel electrical system. Bench test alternator and provide test results.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2005
Resolved 11 February 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 9 February 2005 Resolved
Properly repair or replace water light for ring buoy.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2005
Resolved 11 February 2005
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 9 February 2005 Resolved
Provide current DOC.
Condition: Placed in Improper Service
Due 9 February 2005
Resolved 11 February 2005
Engineering › Bilge Water Management System › Hose
Issued 16 November 2004 Resolved
Replace wasted bilge pump discharge hose.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 November 2004
Engineering › Bilge Water Management System › Pump
Issued 16 November 2004 Resolved
Secure bilge pump to hull.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 November 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 November 2004 Resolved
Repair broken signal wire at transfer case.
Due 16 December 2004
Resolved 30 November 2004
Fire Fighting › Ventilation Systems › Fans
Issued 16 November 2004 Resolved
All power ventilation fans must shut down when fixed system is activated.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 November 2004
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 16 November 2004 Resolved
Provide operations check off sheet to account for all through hull fittings prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 November 2004
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 26 September 2004 Resolved
Provide proof of enrollment in a chemical testing program as required by 46 CFR Part 16.
Action required: 705 - Other - as specified
Due 27 September 2004
Resolved 27 September 2004
Resolution: Received documents attesting to enrollment in a chemical testing program.
Lifesaving › Hand Flares › Condition
Issued 18 September 2003 Resolved
Two (2) orange flares expired.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 September 2003
Resolved 18 September 2003
Resolution: Two (2) flares added before end of inspection.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 18 September 2003 Resolved
Two (2) adult lifejackets.
Condition: Unknown
Due 18 September 2003
Resolved 18 September 2003
Resolution: Added two (2) lifejackets.
Engineering › Electrical Distribution System (service)
Issued 18 September 2003 Resolved
Bilge pump discharge pipe was restricted. LEGACY COMPONENT DESC: Bilge Pump
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 September 2003
Resolved 18 September 2003
Resolution: Pipe was cleaned and tested all sat before inspection ended.
Lifesaving › Buoyant Apparatus
Issued 10 September 2001 Resolved
Provide lifering clip for ringbouy water light. LEGACY COMPONENT DESC: lifering clip
Condition: Improper Installation
Due 24 September 2001
Resolved 20 September 2001
Resolution: Outstanding item was corrected to the satisfaction of the attending marine inspector.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 10 September 2001 Resolved
Mark fire damper pull pin location in a visible location above seat line.
Due 24 September 2001
Resolved 20 September 2001
Resolution: Outstanding item was corrected to the satisfaction of the attending marine inspector.
Engineering › Gasoline Engine (propulsion)
Issued 10 September 2001 Resolved
Mark location of Emergency fuel shutoff above chair line in a visible location.
Condition: Unknown
Due 24 September 2001
Resolved 20 September 2001
Resolution: Outstanding item was corrected to the satisfaction of the attending marine inspector.
Engineering
Issued 28 September 2000 Resolved
REPLACE OR PROVE THAT FUEL STRAINER MEETS 46 CFR 182.455(b)(6).
Condition: Unknown
Due 5 March 2001
Resolved 1 March 2001
Lifesaving
Issued 1 September 2000 Resolved
Provide visual distress signals in a brightly colored water tight containerIAW 46 CFR 180.68 and 185.614._x001C_
Condition: Unknown
Due 1 September 2000
Resolved 1 September 2000
Navigation
Issued 1 September 2000 Resolved
Provide two portable lights IAW 46 CFR183.430
Condition: Unknown
Due 1 September 2000
Resolved 1 September 2000
Engineering
Issued 1 September 2000 Resolved
Replace fuel vent line and vent to meet 46 CFR 182.450 (c) (.625 OD)
Condition: Unknown
Due 1 September 2000
Resolved 1 September 2000
Fire Fighting
Issued 1 September 2000 Resolved
Provide 1 B-I and 2 B-II sized fire extinguishers IAW 46 CFR 181.520
Condition: Unknown
Due 1 September 2000
Resolved 1 September 2000
Fire Fighting
Issued 1 September 2000 Resolved
Provide hand bilge pump IAW 46 CFR 182.520.
Condition: Unknown
Due 1 September 2000
Resolved 1 September 2000
Lifesaving
Issued 1 September 2000 Resolved
Provide first aid kit IAW 46 CFR.
Condition: Unknown
Due 1 September 2000
Resolved 1 September 2000
Lifesaving
Issued 1 September 2000 Resolved
Provide life ring buoy IAW 46 CFR 180.70, orange in color, retro tape, nameof vessel, float light, and floatable 60 ft of line._x001C_
Condition: Unknown
Due 1 September 2000
Resolved 1 September 2000
Deck/Cargo
Issued 1 September 2000 Resolved
Provide bow cleat/bitts for anchoring.
Condition: Unknown
Due 1 September 2000
Resolved 1 September 2000
Deck/Cargo
Issued 1 September 2000 Resolved
Provide mooring lines and 4 mooring cleats.
Condition: Unknown
Due 1 September 2000
Resolved 1 September 2000
Documentation
Issued 1 September 2000 Resolved
Provide radio station license and radio safety certificate (FCC)
Condition: Unknown
Due 1 September 2000
Resolved 1 September 2000
Fire Fighting
Issued 1 September 2000 Resolved
. Provide alternative means to deploy starboard fire damper - ladder interferes.
Condition: Unknown
Due 1 September 2000
Resolved 1 September 2000
Navigation
Issued 1 September 2000 Resolved
Post emergency broadcast procedures.
Condition: Unknown
Due 1 September 2000
Resolved 1 September 2000
Engineering
Issued 1 September 2000 Resolved
Replace or prove that the fuel strainer meets 46 CFR 182.455(b)(6).
Condition: Unknown
Due 1 September 2000
Resolved 1 September 2000
Lifesaving
Issued 1 September 2000 Resolved
Provide 47 adult PFDs and 5 children size PFDs.
Condition: Unknown
Due 1 September 2000
Resolved 1 September 2000
Documentation
Issued 1 September 2000 Resolved
Provide proof that entire crew is enrolled in random drug testing program IAW 46 CFR 16.
Condition: Unknown
Due 1 September 2000
Resolved 1 September 2000
Navigation
Issued 1 September 2000 Resolved
Provide navigation publications IAW 46 CFR 184, including charts.
Condition: Unknown
Due 1 September 2000
Resolved 1 September 2000
Navigation
Issued 1 September 2000 Resolved
Provide marine compass w/light IAW 46 CFR 184.402.
Condition: Unknown
Due 1 September 2000
Resolved 1 September 2000
Construction/Loadline
Issued 1 September 2000 Resolved
Provide vessel name and hailing port on stern. (min. 3inches high)
Condition: Unknown
Due 1 September 2000
Resolved 1 September 2000
Fire Fighting
Issued 1 September 2000 Resolved
Place on board 3 fire buckets IAW 46 CFR 181.600
Condition: Unknown
Due 1 September 2000
Resolved 1 September 2000
Construction/Loadline
Issued 1 September 2000 Resolved
Label both watertight doors IAW 46 CFR 185.610
Condition: Unknown
Due 1 September 2000
Resolved 1 September 2000
Lifesaving
Issued 1 September 2000 Resolved
Provide-make vessel available for fire and man overboard drills. Provide logbook of training.
Condition: Unknown
Due 1 September 2000
Resolved 1 September 2000
Documentation
Issued 1 September 2000 Resolved
Post original COI, stability letter, and master's license.
Condition: Unknown
Due 1 September 2000
Resolved 1 September 2000
Documentation
Issued 1 September 2000 Resolved
Provide original certificate of documentation.
Condition: Unknown
Due 1 September 2000
Resolved 1 September 2000
Accommodation/Occupational Safety
Issued 1 September 2000 Resolved
Provide pollution placard, garbage placard, and lifejacket donning placards.
Condition: Unknown
Due 1 September 2000
Resolved 1 September 2000
Navigation
Issued 1 September 2000 Resolved
Provide VHF-FM radio IAW 46 CFR 184.502.
Condition: Unknown
Due 1 September 2000
Resolved 1 September 2000

Casualty record · 4

13 January 2005Routine · role: Involved in a Marine Casualty · activity 2356091
11 February 2005Routine · role: Involved in a Marine Casualty · activity 2290646
29 March 2006Routine · role: Involved in a Marine Casualty · activity 2655529
24 May 2006Routine · role: Involved in a Marine Casualty · activity 2666371
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

THE GATOR (2005–2006). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.