MAURY USCG vessel records
← All vessels

TRUE COURAGE

TRUE COURAGE is a 2016 freight ship. The Coast Guard has recorded 3 inspections since 2018, most recently in May 2021, along with 4 deficiencies.

Records from 2018 to 2021. Most recent: inspection, 13 May 2021.

Built
2016
Last inspected
13 May 2021
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 13 May 2021
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2018–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9750830
1419121
Flag
LIBERIA
Maury page id
psix-1419121

Documentation record

Tonnage as PSIX records it58940 - Convention (Subpart B), Net Ton
182644 - Dead Weight, Metric Ton
207639 - Displacement, Metric Ton
93286 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 3

13 May 2021 PSC B · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7195762
4 May 2021 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7188744
7 July 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6460469

Deficiency record · 4

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 May 2021 Resolved
07199 - Means shall be provided to control leaks of flammable liquids. PSCO observed fuel accumulation at the fuel filters and drip pans under each on the nmber 2 and 3 generators. 74SOLAS(2014)II-2/4.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2021
Resolution: Received class report attesting to repairs.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 13 May 2021 Resolved
06199 - The following Load Lines shall be used: The Summer [name withheld] indicated by a line marked "S", the Winter [name withheld] indicated indicated by a "W", the Tropical [name withheld] indicated by a line marked "T", Fresh Water [name withheld] indicated by "F", Tropical Fresh Water [name withheld] indicated by "TF". PSCO observed the Load Line Markings were not in accordance with the ship's ICLL Certificate or Load Line Convention. ICLL 66/Reg. 6.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2021
Resolved 16 May 2021
Resolution: Received class report attesting to repairs.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 May 2021 Resolved
Oil gauges shall be maintained in proper condition to ensure accurate functioning. PSCO observed the "FO settling tank" sounding level gauge held open by a clamp. 74SOLAS(14) II-2/4.2.2.3.5.3
Action required: 10 - Deficiency Rectified
Due 13 May 2021
Resolved 13 May 2021
Resolution: Crew removed clamp holding "FO settling tank" sounding level gauge.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 July 2018 Resolved
1160 - Holds and Tanks- The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. While de-ballasting the #6 cargo hold, the cargo tank ventilation was not open creating a vacuum in the tank. As a result, the # 6 cargo tank hatch cover was drawn completely into the tank and is resting at the bottom of the tank. Provide class report and repair plan prior to vessel movement. SOLAS 74(a) 2014 cons. I/11 60a
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 May 2021
Resolution: Conducted deficiency check on-board with vessel crew. Also, received class report clearing deficiencies issued 07JUL2018 by Sector New Orleans as documented in MISLE activity # 6460469

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.