BLACKBIRD

BLACKBIRD is a 2017 passenger vessel (inspected). The Coast Guard has recorded 20 inspections since 2016, most recently in May 2025, along with 15 deficiencies, 3 operational controls and 2 casualty investigations between 2022 and 2024.

Records from 2016 to 2025. Most recent: inspection, 6 May 2025.

Built
2017
Last inspected
6 May 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 6 May 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ4307
1419186
Flag
UNITED STATES
Maury page id
psix-1419186

Documentation record

Registered dimensions (L × B × D)52.0 ft × 17.3 ft × 5.3 ft
Registered tonnagegross 24 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderARMSTRONG MARINE INC · PORT ANGELES, WA, UNITED STATES · built 2017
Hull materialAluminum
PropulsionJet Drive
Hull shapeShip
Hull configurationTwin Hull
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 2 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it24 - Simplified, Gross Ton
19 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 20

6 May 2025 Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8129349
3 March 2025 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8087289
29 May 2024 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7921559
6 May 2024 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7907529
27 March 2024 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7886105
26 March 2024 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7892578
31 May 2023 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7697088
8 May 2023 Deficiency Check · Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7684338
22 March 2023 Drydock Extension · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7655154
11 October 2022 In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7575550
11 October 2022 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7626511
5 May 2022 Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7438017
13 May 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7195385
25 February 2021 Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7146459
22 May 2020 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6957858
6 August 2019 Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6768577
28 March 2019 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6650890
10 May 2018 Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6413994
3 October 2016 Plan Review "T" Boat · COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6128588
26 September 2016 Plan Review "T" Boat · Construction Oversight · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6026725

Deficiency record · 15

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 May 2025 Resolved
Each ring life buoy on a vessel must: Be approved in accordance with 160.050 in subchapter Q of this chapter. Ring buoys onboard found marked for recreational use with 160.064. Replace ring buoys with approved type. 46 CFR 180.70
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 20 May 2025
Resolution: Accepted photo of correct ring buoy.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 29 May 2024 Resolved
A hatch exposed to the weather must be watertight, except that the following hatches may be weathertight: A hatch on a vessel that operates only on protected waters. Marine inspector observed significant water accumulation in forward void, semi-permanent weathertight hatch cover is leaking through silicone seal and bolt holes. Provide adequate weathertight seal to the satisfaction of the marine inspector. 46 CFR 179.360(a)(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2024
Resolved 12 June 2024
Resolution: Forward hatch secured from weather exposure.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 March 2024 Resolved
A pre-engineered fixed gas fire extinguishing system must: Be capable of manual actuation from outside the space in addition to automatic actuation by a heat detector. The fixed fire extinguishing system in the starboard engine room deployed during exhaust emission testing. Vessel must conduct satisfactory service on the fire extinguishing system to the satisfaction of the Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2024
Resolution: Replaced fireboy system and submitted satisfactory fire servicing report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 October 2022 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests including the following: Inspection of all machinery essential to the routine operation of the vessel including generators and cooling systems. Both non metallic expansion joints coming out of the muffler on starboard main engine are leaking on the underside.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2022
Resolved 26 October 2022
Resolution: Attended vessel, tested engine, repairs SAT.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 October 2022 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. When repairs are made during an emergency, the owner, managing operator, or master shall notify the OCMI as soon as practicable after such repairs or alterations are made. Crew discovered holed piping on the fire main following a fire drill on 10OCT2022. Crew conducted temporary repair on the morning of 11OCT2022 and operated the vessel in passenger service without notifying the [name withheld] permanent repairs to the fire main to the satisfaction of the OCMI.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 11 October 2022
Resolved 12 October 2022
Resolution: Verified proper repairs and operational test of fire main.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 May 2022 Resolved
At each intial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests including the following: Inspection of the fire main system. Single fire main onboard found with two pinholes on the backside of the piping leading from the main deck to the second deck. Make permanent repairs to the satisfaction of attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 May 2022
Resolved 10 May 2022
Resolution: Tested fire main and pipe system, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 May 2022 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests including the following: Inspection of all machinery essential to the routine operation of the vessel including generators and cooling systems. Port side fiberglass muffler found cracked and weeps water when operating at full speed; starboard non metallic expansion joint on exhaust just before the muffler was leaking on the underside at a rate of 1 drop per second onto battery box below. Repair port and starboard exhaust to the satisfaction of attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2022
Resolved 1 June 2022
Resolution: Verified repairs to both exhausts and conducted operational test.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 5 May 2022 Resolved
An inflatable liferaft or inflatable buoyant apparatus must be serviced at a facility specifically approved by the Commandant for the particular brand, and in accordance with servicing procedures meeting the requirements of part 160, subpart 160.151, of this chapter. IBA servicing records were not available.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2022
Resolved 1 June 2022
Resolution: Verified IBA servicing records.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 May 2022 Resolved
Stations in the maritime service must be licensed by the FCC either individually or by fleet. Station license was not present onboard. 47 CFR 80.13(a).
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2022
Resolved 1 June 2022
Resolution: Verified presence of station license.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 May 2022 Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request. DAPI records for 2022 were not present onboard.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2022
Resolved 1 June 2022
Resolution: Inspected DAPI records.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 May 2021 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2021
Resolved 28 May 2021
Resolution: Received photographs from operator rectifying all remaining deficiencies (see documents)
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 May 2021 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2021
Resolved 28 May 2021
Resolution: Received photographs from operator rectifying all remaining deficiencies (see documents)
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 6 August 2019 Resolved
A vessel must be provided with a stability letter, the stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. Vessels stability letter was not onboard. 46 CFR 176.306
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2019
Resolved 19 September 2019
Resolution: Vessel posted stability letter of sister vessel.
Fire Fighting › Ventilation Systems › Ducts
Issued 7 August 2017 Resolved
Make permanent repairs to both the forward and aft air dampers on both the SEQUOIA and BLACKBIRD so that they are able to be closed quickly in the event of a fire. Prove proper operation of every damper in the presence of attending marine inspector. 46CFR182.465
Action required: 705 - Other - as specified
Due 21 August 2017
Resolved 24 August 2017
Engineering › Diesel Engine (propulsion-direct drive) › Piping (air intake)
Issued 29 June 2017 Resolved
Test engines at full operating temperature and verify that the temperature does not rise above 30 F degree from ambient outside air temp to the intake air temp on the engine to the satisfaction of the attending marine inspector. 46CFR182.100
Action required: 705 - Other - as specified
Due 21 August 2017
Resolved 24 August 2017

Casualty record · 2

11 October 2022Routine · role: Involved in a Marine Casualty · activity 7626511
26 March 2024Routine · role: Involved in a Marine Casualty · activity 7892578
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.