Records from 2016 to 2026. Most recent: operational control imposed, 21 February 2026.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 February 2026
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Identified inoperable port side jet engine. Determine root cause and conduct sea trials to the satisfaction of the attending Marine Inspector.
46 CFR 119.200(a)
Condition: Design Flaw
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 February 2026
Resolution: Vessel rep provided DMI tech report and DMI attended Sea Trials to confirm repairs.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 November 2025
Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 or be specifically approved by the Commandant. Fire main found with non compliant hose on 21NOV25. Two sections were verified satisfactory on 26NOV25, but entire length is not fully compliant. Install SAE 1942 compliant hose in entire length of non metallic portions of fire main.
46 CFR 182.720
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 December 2025
Resolved 18 May 2026
Resolution: Accepted photos and documentation of correct hoses.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 21 November 2025
Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 or be specifically approved by the Commandant. Flexible nonmetallic hose installed in fire main in machinery space does not meet SAE J-1942.
46 CFR 182.720
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 November 2025
Resolution: MI verified arrangement of fire main.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 6 November 2025
Resolved
At each inspection for certification and every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Starboard side rail and bulwark damage identified on 29JUL25 has not been properly repaired. On 6NOV2025, Marine Inspectors identified new damage along the starboard side that requires permanent repair. Provide repair proposal for all starboard side damage prior to affecting repairs and verify satisfactory repairs through the local OCMI.
46 CFR 176.830
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 November 2025
Resolution: Verified repairs.
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 14 October 2025
Resolved
At a minimum, each placard must notify the reader of the operating requirements contained in 151.67 through 151.73 as they apply to that ship. The following requirements should also be prominently stated: the discharge of all garbage is prohibited into the navigable waters of the U.S. and into all other waters except as specifically allowed; discharge of all forms of plastic into all waters is prohibited; a person who violates the above is liable for civil and/or criminal penalties; and regional, state, and local restrictions on garbage discharges also may apply. Observed that the garbage placard was missing. (33 CFR 151.59 (c))
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2025
Resolved 21 October 2025
Resolution: Operator submitted satisfactory photos of displayed garbage signage.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 October 2025
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked "First-Aid Kit". A first-aid kit must be easily visible and readily available to the crew. Observed that first aid kit had expired materials. (46 CFR 184.710)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2025
Resolved 30 October 2025
Resolution: Operator sent photo of new first-aid kit components.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 October 2025
No resolution recorded
Whenever damage or deterioration to hull plating or structural members may affect the seaworthiness or a vessel is discovered, the cognizant OCMI may conduct an internal structural examination in any affected space and may require the vessel to effect permanent repairs. MI observed 1/16" pitting in the vessel's STBD void in passenger cabin. Submit repair proposal and affect repairs to the satisfaction of the MI prior to next credit dry dock (46 CFR 176.600(d))
Action required: 705 - Other - as specified
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 29 August 2025
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Vessels gangway handrails broke in 2 areas at the weld seams. Conduct repairs to the handrails to the satisfaction of the MI.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2025
Resolved 4 September 2025
Resolution: Provided photos of hand rails, added to doc tab.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 29 July 2025
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. MI observed 12" fracture on top of the starboard bulwark located outboard of main deck fire main and 3" fracture to the outboard bulwark below. Provide repair proposal and affect permanent repairs to the satisfaction of MI.
46 CFR 176.830
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2025
Resolved 21 November 2025
Resolution: Verified repairs.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 29 July 2025
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. MI observed crack along base of starboard aft rail to bulwark connection located just aft of loading door. Provide repair proposal and affect permanent repairs to the satisfaction of MI.
46 CFR 176.830
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2025
Resolved 21 November 2025
Resolution: Verified repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 October 2024
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personal injury. MI observed outboard side of raw water cooling pipe for starboard main engine leaking a constant stream of water from a pinhole fracture. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 October 2024
Resolved 7 October 2024
Resolution: Operator replaced damaged piping in kind with spare.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 October 2024
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material IAW 46 CFR 164.018 or other standard specified by the Commandant. MI observed ring buoy without Type II retroreflective material. 46 CFR 185.604(i)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2024
Resolved 13 January 2025
Resolution: Verified proper retro on life buoy.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 October 2024
Resolved
Each battery must be located as high above the bilge as practicable, secured to protect against shifting with the roll and pitch of the vessel, and free from exposure to water splash or spray. MI observed house battery compartment on starboard side with significant water ingress from splash and spray due to failed hatch gasket. 46 CFR 183.350(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2024
Resolved 13 February 2025
Resolution: Verified weathertightness of seal.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 October 2024
Resolved
A vessel with batteries of adequate capacity to supply the loads specified in paragraph (a)(1) of this section for three hours. MI observed 12V house battery arrangeement lose approximately 2V of charge without load in a 15 minute period. Port side battery is unable to hold charge without shore power, or alternator for required time. 46 CFR 183.310(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2024
Resolved 7 October 2024
Resolution: Operator replaced battery with new
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 7 October 2024
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas system. Quick closing ventilation dampers are not closing fully without assistance from crew in spaces. 46 CFR 182.460(h)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2024
Resolved 13 January 2025
Resolution: Verified closure of damper.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 August 2024
Resolved
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended. Steering shaft at the top of jet drive on starboard side leaks approximately one tablespoon when put to port or starboard. Conducted repairs to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2024
Resolved 13 February 2025
Resolution: Verified operation leak free.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 30 August 2024
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following Inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks. Starboard outboard structural support that connects from transom to beneath swim platform is fractured in three locations. Submit repair proposal to crop and renew fractured structure.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2024
Resolved 13 February 2025
Resolution: Verified replacement of fractured section.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 August 2024
Resolved
Whenever there is a hazardous condition, as defined by 46 CFR 175.400, on board the vessel, the owner, master, agent, or person in charge shall immediately notify the Captain of the Port of the port of place of destination and the Captain of the Port or place in which the vessel is located of the hazardous conditions. Marine Inspector observed active water leak from starboard jet drive steering lever which onboard records indicate was leaking at an average rate of 12 gallons per day and has been occurring for more than 30 days. Affect proper repairs to stop water ingress and conduct satisfactory sea trials with a Marine Inspector present.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 30 August 2024
Resolution: Crew replaced corroded zerk fitting allowing proper lubriction seal. Conducted sat underway seal trials.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 28 August 2024
Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. During inspection of starboard main engine, Marine Inspector found pockets of collected engine oil on top of the engine, oil soaked lagging, and oil saturated sorbent materials stuffed in several areas of the engine to collect an ongoing oil leak. Determine source of leak, provide corrective actions and conduct operational test with a Marine Inspector present.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 31 August 2024
Resolution: Crew performed maintenance on engine and cleaned several gaskets. Witnessed sat sea trials with no leaks detected.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 28 August 2024
Resolved
At each inspection for certification and at every other vessel inspection, the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard or clog bilge pumping systems. Marine Inspector found several gallons of oily water and multiple oil soaked sorbent pads floating in the bilge due to ongoing water ingress and starboard engine leak. Properly remove all oil, water, and saturated materials from the starboard engine compartment and complete reinspection with local OCMI.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 30 August 2024
Resolution: Verified removal of oily water and sorbent materials.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 August 2024
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10; for fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. Marine Inspector found all fixed and portable fire suppression systems onboard overdue for servicing since 31JUL24. Review of onboard records showed crew noted overdue fire fighting systems and management failed to take appropriate action to rectify. Provide evidence of servicing for all fire fighting equipment onboard to the satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 30 August 2024
Resolution: Verified servicing report and all onboard extinguishers.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 June 2024
Resolved
Materials used in piping systems must meet the requirements of this subpart and be otherwise acceptable to the [name withheld] observed five spots with significant pitting on the fire main piping approximately three feet above the main deck that were covered over with temporary repairs that require crop/renewal of pipe.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 June 2024
Resolved 5 June 2024
Resolution: Verified crop/renew and op test.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 12 July 2023
Resolved
...(a) Each EPIRB, must be tested monthly. (b) The EPIRB's battery is replaced after it is used, or before the date required by FCC regulations in 47 CFR part 80, whichever comes sooner; and (c) The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable... EPIRB battery is expired, and missing monthly testing from January 2023- June 2023, replace battery and ensure monthly testing.
46 CFR 185.728(a)(b)(c)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2023
Resolved 30 August 2023
Resolution: Operator installed and properlly registered EPIRB.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 12 July 2023
Resolved
A person may not employ or engage an individual in
a position required to hold an MMC unless that
Individual maintains a current medical certificate.
Provide a current medical certificate.
46 CFR 15.401(c)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2023
Resolved 23 August 2023
Resolution: Medical certificate was provided for master.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 July 2023
Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing to the marine
marine inspector. If any of the equipment or records
have not been properly maintained, a qualified
servicing facility must perform the required inspections
Provide marine inspector with servicing report of fire
equipment.
46 CFR 176.810(b)(iv)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2023
Resolved 13 July 2023
Resolution: Operator provided MI with Fire Service report
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 July 2023
Resolved
At least one ring life buoy must be fitted with a lifeline. At least one must not have a lifeline attached. Each lifeline on a ring life buoy must:
(1) Be buoyant; (2) Be of at least 18.3 meters (60 feet) in length; (3) Be non-kinking; (4) Have a diameter of at least 7.9 millimeters (5/16 inch); (5) Have a breaking strength of at least 5 kilonewtons (1,124 pounds); and
(6) Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light... Life ring on main deck is deteriorated replace life ring and lifeline.
46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2023
Resolved 13 July 2023
Resolution: Operator replaced life ring
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 July 2023
Resolved
Each battery must be located as high above the bilge as
practicable, secured to protect against shifting with
roll and pitch of the vessel, and free from exposure
to water splash or spray... Starboard engine room
inboard battery has a cracked lid.... Repair or replace battery box lid.
46 CFR 183.350(b)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2023
Resolved 13 July 2023
Resolution: Replaced broken battery cover
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 July 2023
Resolved
A vessel on a lakes, bays, and sounds, or rivers route
must carry: (1) Three hand red flare distress signals
and (2) Three hand orange smoke distress signals. Vessel
is missing one red hand flare.
46 CFR 180.68(b)(1)&(2)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2023
Resolved 14 July 2023
Resolution: Operator replaced missing red flare
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 12 July 2023
Resolved
Machinery space boundaries. Boundaries that separate machinery spaces from accommodation spaces, service spaces, and control spaces must be lined with noncombustible panels or insulation approved in accordance with § 164.009 in subchapter Q of this chapter, or other standard specified by the Commandant...Wire transits in Port and Starboard engine room vapor barrier have a foam/plastic wrapping, remove wrapping from wires transiting the vapor barrier.
46 CFR 177.410(c)(4)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2023
Resolved 14 July 2023
Resolution: Foam/plastic removed from vapor barrier and new putty was installed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 July 2023
Resolved
All equipment, including switches, fuses, lampholders, etc., must be suitable for the voltage and current utilized... Fuse on Starboard wiring panel is severely corroded, replace fuse and clean the area.
46 CFR 183.220(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2023
Resolved 13 July 2023
Resolution: Installed new fuse and cleaned corraion from the area
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 July 2023
Resolved
A suitable hull strainer must be installed in the circulating raw water intake line of an engine cooling
water system.... Clean or replace sea strainer on Port
and Starboard main engine raw water intake.
46 CFR 183.430
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2023
Resolved 13 July 2023
Resolution: Sea strainers were cleaned out
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 July 2023
Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request... Provide marine inspector with chemical testing records to complete DAPI audit.
46 CFR 16.260(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2023
Resolved 14 July 2023
Resolution: DAPI documentation proveded to MI
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 12 July 2023
Resolved
The initial inspection may include an inspection of the following: The arrangement, installation... including piping, main and auxiliary machinery... pollution prevention equipment. Port and starboard engine room bilges have excessive oil and debris. Engine room bilges were not tested due to this. Clear engine room bilges and ensure no oily residue remains in the lines.
46 CFR 176.402(c)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2023
Resolved 14 July 2023
Resolution: Tested e/r bilges in deficiency check all sat
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 12 July 2023
Resolved
An inspection for renewal of a certificate of Inspection is conducted to determine if the vessel is in satisfactory condition...the OCMI may require the vessel to get underway. Underway portion of COI inspection not completed. Request subsequent inspection to witness man overboard drills and underway checks.
46 CFR 176.404(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2023
Resolved 14 July 2023
Resolution: Witnessed sat MOB drill
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 12 July 2023
Resolved
Each vessel that relies on electricity to power the following loads must be arranged so that the loads can be energized from two sources of electricity: (iv) Navigation equipment and lights.... Vessels navigation equipment inoperable. Make repair to the satisfaction of the marine inspector.
46 CFR 183.310(a)(1)(iv)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2023
Resolved 14 July 2023
Resolution: Repairs made to electrical system and nav equip is now operational
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 12 July 2023
Resolved
A vessel must comply with the applicable requirements for any radio installations as set forth by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessels radio equipment is inoperable, make repair to the satisfaction of the marine inspector.
46 CFR 184.502
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2023
Resolved 14 July 2023
Resolution: Operator repaired electrical eqipment and radios are working as intended
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 September 2022
Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Strainer was not three times the diameter of the bilge pipe.
46 CFR 182.510(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 November 2022
Resolution: Verified both engine room strainers were suitable size.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 September 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to: protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in the electrical equipment, and electrical shock. Wires in port forward space under deck were not properly secured or locked out from breaker panel.
46 CFR 183.200(b)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 November 2022
Resolution: Verified dead end wires were properly capped.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 21 September 2022
Resolved
The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. The name of the vessel was not marked on the port or starboard bow.
46 CFR 67.1239(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 December 2022
Resolution: Name of vsl was painted on bow and stern.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 21 September 2022
Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas or liquid, the temperature of which exceeds 65.5C, must be suitably insulated where necessary to prevent injuries. Exhaust lagging on both engines was worn and needs to be replaced.
46 CFR 177.970
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 November 2022
Resolution: Verefied replacement of lagging.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 21 September 2022
Resolved
There must be a means of accurately determining the amount of fuel in each fuel tank either by sounding, through a separate sounding pip or a fill pipe, or by an installed marine type fuel gauge.
46 CFR 182.445(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 November 2022
Resolution: Verified operation of bridge fuel indicators.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 21 October 2019
Resolved
Each fire drill must include: Instruction in the use and location of fire alarms, extinguishers, and any other fire fighting equipment onboard. Vessel needs instructions on board indicating that the ignition must be turned in order to use FIREBOY override function.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 October 2019
Resolved 6 November 2019
Resolution: Vessel representative sent photo of instructions posted on vessel.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 October 2019
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible. Vessel is missing a chart, provide proof of updated charts to marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2019
Resolved 6 November 2019
Resolution: Vessel representative provided proof of chart purchase.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 2 August 2018
Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 (incorporated by reference; see 46 CFR 175.600) or be specifically approved by the Commandant. Firemain hose is currently shield sanitation hose and is not to be used for the firemain. Replace with SAE J-1942 or equivalent hose.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 August 2018
Resolved 26 February 2019
Resolution: Vessel rep installed flexible hose that meets SAE J-1942 specs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 August 2018
Resolved
Flexible hose designed for use with hose clamps may be installed with two clamps, at both ends of the hose.
Bilge system hose currently single clamped.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 August 2018
Resolved 26 February 2019
Resolution: Double hose clamps were installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 August 2018
Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Strainers missing from bilge piping in both the port and stbd aft sections of the engine spaces.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 August 2018
Resolved 26 February 2019
Resolution: Strainers were installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 August 2018
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Flywheels are exposed in both engine spaces. Provide a method of protection from hazard.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 August 2018
Resolved 26 February 2019
Resolution: Company updated policy to mandate no engine room entry unless machinery is not running.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 2 August 2018
Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. COD Application has been submitted to NVDC. Provide copy of COD once received.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 August 2018
Resolved 26 February 2019
Resolution: Vessel has received valid COD
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 August 2018
Resolved
The provisions of Part III of Title III of the Communication Act require United States vessels which transport more than six passengers for hire while such vessels are being navigated on any tidewater within the jurisdiction of the United States adjacent or contiguous to the open sea, or in the open sea to carry a radiotelephone installation complying with this subpart. Vessel is missing the radiotelephony safety certificate. 47 CFR 80.901
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2018
Resolved 26 February 2019
Resolution: Proper FCC documents have been issued.