MAURY USCG vessel records
← All vessels

JOSEPH F WEBER

JOSEPH F WEBER is a 2018 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2017, most recently in March 2025, along with 4 deficiencies and 1 casualty investigation in 2021.

Records from 2017 to 2025. Most recent: inspection, 31 March 2025.

Built
2018
Last inspected
31 March 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 31 March 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2017–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK3453
1420698
Flag
UNITED STATES
Maury page id
psix-1420698

Documentation record

Registered dimensions (L × B × D)148.3 ft × 52.0 ft × 10.7 ft
Registered tonnagegross 91 / net 61
ITC dimensions (L × B × D)148.3 ft × 52.0 ft × 10.7 ft
ITC tonnagegross 386 / net 115
BuilderSOUTHWEST SHIPYARD, L.P. · HOUSTON · built 2018
Hull materialSteel
PropulsionElectric Motor
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORT ARANSAS, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 2 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it386 - Convention (Subpart B), Gross Ton
91 - Regulatory (Subpart C or D), Gross Ton
115 - Convention (Subpart B), Net Ton
61 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 16

31 March 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8102474
17 April 2024 In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7897883
23 January 2024 Drydock Exam · Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7853371
7 June 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7709642
15 March 2022 Drydock Exam · Administrative Inspection · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7412265
20 January 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7383219
17 December 2021 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7369782
17 December 2021 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7369819
4 October 2021 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7326613
3 February 2021 Administrative Inspection · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7135192
24 September 2020 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7064252
6 February 2020 Administrative Inspection · Annual Inspection · Drydock Exam · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6904064
6 August 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6826808
4 February 2019 In-Service Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6619701
20 November 2018 COI Inspection · DAPI Audit
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6584080
24 January 2017 Administrative Inspection · Construction Oversight · Examination of Repairs · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6076068

Deficiency record · 4

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 September 2020 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment; For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility may be required to perform the required inspections, maintenance procedures, and hydrostatic pressure tests.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 October 2020
Resolution: Witnessed fixed CO2 system testing; All SAT.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 15 November 2018 Resolved
Vessel was constructed in Houston Texas and will operate out of Port Aransas Texas. Vessel has conducted sea trials and a COI inspection with the exception of fire drill. Vessel must conduct fire and safety drills with crew and conduct a new to zone inspection before carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 February 2019
Resolution: Inspected all life saving equipment and fire fighting equipment passed in spection. Conducted all required drills for COI. Vessel passed all drills
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 November 2018 Resolved
essel was constructed in Houston Texas and will operate out of Port Aransas Texas. Vessel has conducted sea trials and a COI inspection with the exception of fire, abandon ship and person overboard drills. Vessel must conduct fire and safety drills with crew and conduct a new to zone inspection before carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 February 2019
Resolution: Inspected all life saving equipment and fire fighting equipment passed in spection. Conducted all required drills for COI. Vessel passed all drills
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 24 January 2017 Resolved
Vessel was constructed in Houston Texas and will operate out of Port Aransas Texas. Vessel has conducted sea trials and a COI inspection with the exception of abandon ship and person overboard drills. Vessel must conduct fire and safety drills with crew and conduct a new to zone inspection before carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 February 2019
Resolution: Inspected all life saving equipment and fire fighting equipment passed in spection. Conducted all required drills for COI. Vessel passed all drills

Casualty record · 1

17 December 2021Routine · role: Involved in a Marine Casualty · activity 7369819
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.