FALCON TRIUMPH is a 2016 freight ship. The Coast Guard has recorded 9 inspections since 2016, most recently in May 2026, along with 3 deficiencies and 2 operational controls.
Records from 2016 to 2026. Most recent: inspection, 20 May 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it36336 - Convention (Subpart B), Gross Ton 21529 - Convention (Subpart B), Net Ton 63480 - Dead Weight, Metric Ton 75206 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page
9 inspections, each with its date, unit and type; 3 deficiencies with the resolution recorded against each; 2 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fir to proceed to sea without danger to the ship or persons on board. Vessel has a breach in the stbd hull IWO FR 17 in void space located approx. 10 ft above the water line. Breached area is a vertical crack extending approx 8 inches just FWD of the frame. Vessel also has an inset of approx. 3 inches across located approx. 5 ft aft but inset is not cracked. All associated frames are intact. 74 SOLAS(20) 1/11.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 July 2023
Resolution: Insert to damaged area was inspected and vacuum box tested to the satisfaction of the attending Class NK surveyor prior to departure.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 20 March 2018Resolved
1499-Other (Prop & Aux. Machinery)- Means shall be provided to control leaks of flammable liquids. PSCO observed DO supply line to MDE had a valve with excessive leak from gasket, and DO saturated insulation. SOLAS 74 a 20114 Cons II-2/4.1.1 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 March 2018
Resolution: CE conducted sat repair of flange, and insulation was replaced.
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 20 March 2018Resolved
0715- Detection- Maintenace testing and inspections shall be carried out based on guidlines developed by the Organization and in a manner having due regard to ensuring the reliability of fire fighting systems and appliances. PSCO observed the crew testing the onboard flame detection system with a lighter. Crew was unable to provide testing procedures that identified this as an approved fire detection method. SOLAS 74 a 2014 Cons II-2/14.2.2.1 16a
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 April 2018
Resolved 27 March 2018
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. New test lamp for flame detectors have been delivered, checked, and found satisfactory.