MAURY USCG vessel records
← All vessels

ETHANE CRYSTAL

ETHANE CRYSTAL is a 2016 tank ship. The Coast Guard has recorded 18 inspections since 2016, most recently in November 2025, along with 1 deficiency.

Records from 2016 to 2025. Most recent: inspection, 13 November 2025.

Built
2016
Last inspected
13 November 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 13 November 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9752278
1422782
Flag
MARSHALL ISLANDS
Maury page id
psix-1422782

Documentation record

Tonnage as PSIX records it57509 - Convention (Subpart B), Gross Ton
59087 - Dead Weight, Ton
78648 - Displacement, Ton
18260 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 18

13 November 2025 COC-GAS Annual · Administrative Inspection · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8264257
2 October 2024 PSC B · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8011690
18 July 2023 PSC B · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7743634
12 July 2023 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7740718
6 September 2022 COC-GAS Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7548741
6 September 2021 PSC B · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7302922
27 September 2020 PSC B · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7064272
9 November 2019 Ballast Water Examination · COC-GAS Annual · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6837546
9 November 2019 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 7082884
28 February 2019 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6727683
29 October 2018 In-Service Inspection · ISPS II Exam · Ballast Water Examination · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6569664
29 October 2018 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6727436
26 October 2018 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6569078
1 November 2017 ISPS II Exam · Ballast Water Examination · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6298171
2 June 2017 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6223847
16 December 2016 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6063281
15 November 2016 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6093339
17 October 2016 COC-GAS Renew · Ballast Water Examination · NPV Safety Exam · PII Safety Exam · ISPS III Exam
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6023561

Deficiency record · 1

Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 15 November 2016 Resolved
In the case of flammable products where cargo containment systems other than independent tanks are used, interbarrier spaces should be provided with a permanently installed gas detection system capable of measuring gas concentrations of 0%-100% by volume. The installed gas detection system for the interbarrier spaces can only read 0%-100% LEL. 74 SOLAS (14CON) Chap VII/Reg 13 IGC Code 13.6.11
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 16 December 2016
Resolution: Sector Houston believed deficiency to be invalid. recommend deficiency be purged. Received Class report attesting to proper operation of newly installed % by volume "readout display" and witnessed operation and testing of installed fixed gas detection.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.