ERATIOS is a 2011 freight ship. The Coast Guard has recorded 6 inspections since 2018, most recently in May 2022, along with 2 deficiencies and 1 operational control.
Records from 2018 to 2022. Most recent: inspection, 6 May 2022.
The 6 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Documentation record
Tonnage as PSIX records it32355 - Convention (Subpart B), Gross Ton 18118 - Convention (Subpart B), Net Ton 54683 - Dead Weight, Metric Ton 65635 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.
Inspection history · 6
6 May 2022Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7445255
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 15 June 2021Resolved
FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY A VAILABLE FOR IMMEDIATE USE.
A BANK OF 11 CO2 BOTTLES FOR THE FIXED FIGHTING SYSTEM WOULD NOT ACTIVATE DURING A MANUAL ACTIVATION DUE TO A COTTER PIN. ON THE ADJACENT BANK, 02 CO2 BOTTLES WOULD NOT ACTIVATE DUE TO BEING DISCONNECTED FROM THE COMMON CABLE.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 19 June 2021
Resolved 19 June 2021
Resolution: Shore service provider connected the links and satisfactorily tested the system. The CO2 system was certified by shore service provider dated 16JUN2021. See attached class report.
09 - Working and Living Conditions › 091 - Living Conditions › Dirty, parasites
Issued 15 June 2021Resolved
THE SECRETARY MAY ORDER ANY VESSEL IN A PORT OR PLACE SUBJECT TO THE JURISDICTION OF THE UNITED STATES TO OPERATE IN A MANNER THE SECRETARY DIRECTS BY REASON OF HAZARDOUS CIRCUMSTANCES IN THE INTEREST OF SAFETY.
THE GALLY, DRY PROVISIONS, AND REEFER COMPARTMENTS WERE INFESTED WITH ROACHES AND FLIES.
Action required: 60 - Rectify deficiencies prior to movement
Due 19 June 2021
Resolved 19 June 2021
Resolution: Shore service provider applied DEMAND CS and NyGuard IGS to living quarters, mess room, galley, offices, and throughout the superstructure. See attached class report.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.