Records from 1989 to 2011. Most recent: inspection, 5 August 2011.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 43
5 August 2011
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4105753
14 February 2011
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3945305
26 February 2010
Examination of Repairs · Annual Inspection · Ballast Water Examination · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3687812
4 February 2009
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3412567
9 December 2008
Examination of Repairs · Annual Inspection · Hull Examination · Ballast Water Examination · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3376895
8 April 2008
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3179787
25 March 2008
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3171799
28 December 2007
Ballast Water Examination · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3121783
4 January 2006
COI Inspection · Hull Examination · Internal Structural Exam · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2560596
23 November 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2539914
23 June 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2400098
5 January 2005
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2269119
26 January 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2000236
12 January 2004
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1983168
31 October 2003
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1939740
2 October 2003
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1925051
12 March 2003
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1758276
26 March 2002
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1597814
18 April 2000
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 185860
25 October 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1399244
25 November 1998
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1364913
19 May 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 38871
19 May 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 109276
14 November 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1446556
2 November 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 781790
29 September 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1118890
9 January 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1424322
12 June 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 761644
10 June 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 200148
2 November 1995
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1428539
27 March 1995
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 828647
15 December 1994
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1463151
10 October 1993
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1387407
28 August 1992
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1462306
24 April 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 13254
21 November 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1246928
5 September 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 939709
15 August 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1253903
25 September 1990
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1241562
23 February 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 929670
12 December 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 912132
14 November 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1226986
25 August 1989
Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 891752
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 9 December 2008
Resolved
Replace both air receivers, or conduct hydro test at 1 1/2 MAWP by next annual exam due date
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 February 2010
Resolved 26 February 2010
Resolution: Two new air receivers installed and tested.
Lifesaving
Issued 25 October 1999
Resolved
Demonstrate compliance with the 8th U.S. Coast Guard District Policy Ltr. dated 12NOV98 "Rescue Boat Requirements on Offshore Supply Vessels" to the satisfaction of the attending Marine Inspector.
Condition: Unknown
Due 25 October 1999
Resolved 25 October 1999
Engineering
Issued 25 November 1998
Resolved
PROVIDE FOR EXAMINATION LEG TO PAD WELD TEST DOCUMENTATION.
Condition: Unknown
Due 25 December 1998
Resolved 2 December 1998
Documentation
Issued 9 January 1997
Resolved
VESSEL LIMITED TO THE FOLLOWING: TO INSIDE THE BOUNDARY LINE WITHIN 8 HOURSOF A HARBOR OF SAFE REFUGE; A MAX DECK CARGO LOAD OF 35 SHORT TONS; A MAX DECK LOAD HEIGHT OF FT. ABOVE MAIN DECK. CONDITIONS REMAINS IN FORCE UNTIL A REVISED STABILITY LETTER/OP MANUAL IS REVIEWED AND APPROVED BY MORMS/MSC.
Condition: Unknown
Due 9 January 1997
Resolved 9 January 1997
Documentation
Issued 15 December 1994
Resolved
PROVIDE, ONBOARD VESSEL, USCG APPROVED OPERATING MANUAL AND STABILITY LETTER.
Condition: Unknown
Due 15 December 1994
Resolved 15 December 1994
Fire Fighting
Issued 15 August 1991
Resolved
RERPAIR PORT VENT (HOLES).
Condition: Unknown
Due 8 October 1991
Resolved 8 October 1991
Deck/Cargo
Issued 15 August 1991
Resolved
PROVIDE LOAD CHART FOR CRANE AS RIGGED.
Condition: Unknown
Due 8 October 1991
Resolved 8 October 1991
Construction/Loadline
Issued 15 August 1991
Resolved
REPAIR WATER TIGHT BETWEEN TANK ROOM AND ENGINE ROOM.
Condition: Unknown
Due 4 October 1991
Resolved 8 October 1991
Navigation
Issued 15 August 1991
Resolved
PROVIDE NOT UNDER COMMAND LIGHTS. PORTABLE OR FIXED.
Condition: Unknown
Due 8 October 1991
Resolved 8 October 1991
Lifesaving
Issued 15 August 1991
Resolved
PROVIDE COAST GUARD APPROVED RESCUE BOAT AND REQUIRED EQUIPMENT (OARS, LOCKS, PAINTER)
Condition: Unknown
Due 8 October 1991
Resolved 8 October 1991
Construction/Loadline
Issued 15 August 1991
Resolved
REPAIR PORT ENGINE ROOM BILGE ALARM.
Condition: Unknown
Due 8 October 1991
Resolved 8 October 1991
Construction/Loadline
Issued 15 August 1991
Resolved
PROVIDE MISSING DOG ON DECK HOUSE DOOR.
Condition: Unknown
Due 8 October 1991
Resolved 8 October 1991
Fire Fighting
Issued 15 August 1991
Resolved
REPAIR, REPLACE OR ADD ADDITIONAL FIRE PUMP TO PROVIDE AT LEAST 60PSI WITH TWO HOSES OPEN.
Condition: Unknown
Due 8 October 1991
Resolved 8 October 1991
Unknown
Issued 12 December 1989
Resolved
PROVIDE VESSEL FOR INSPECTION TO VALIDATE INSTALLATION OF ANCHORING SYSTEM.
Condition: Unknown
Due 12 December 1989
Resolved 12 December 1989
Lifesaving
Issued 25 August 1989
Resolved
INSTALL FIX EMBARKATION LADDER.
Condition: Unknown
Due 25 August 1989
Resolved 25 August 1989
Navigation
Issued 25 August 1989
Resolved
INSTALL STEERING ALARM SYSTEM IF READMEASUREMENT IS GREATER THAN 100 GROSS TONS.
Condition: Unknown
Due 25 August 1989
Resolved 25 August 1989
Navigation
Issued 25 August 1989
Resolved
INSTALL RUDDER INDICATOR IF READMEASUREMENT IS GREATER THAN 100 GROSS TONS.
Condition: Unknown
Due 25 August 1989
Resolved 25 August 1989
Unknown
Issued 25 August 1989
Resolved
PROVIDE UP TO DATE UT REPORT OF ALL LEGS.
Condition: Unknown
Due 25 August 1989
Resolved 25 August 1989
Deck/Cargo
Issued 25 August 1989
Resolved
PROVIDE PROPER ANCHOR AND LINE.
Condition: Unknown
Due 25 August 1989
Resolved 25 August 1989
Documentation
Issued 25 August 1989
Resolved
VESSEL TO BE READMEASURED OR MANNING WILL BE INCREASED.
Condition: Unknown
Due 25 August 1989
Resolved 25 August 1989
Documentation
Issued 25 August 1989
Resolved
SUBMIT FOR APPROVAL STABILITY CALCULATION AND OPERATIONAL MANUAL TO MARINE SAFETY CENTER WASHINGTON, DC.
Condition: Unknown
Due 25 August 1989
Resolved 25 August 1989
Unknown
Issued 25 August 1989
Resolved
SUBMIT PLANS AND INSTALL TILT ALARMS.
Condition: Unknown
Due 25 August 1989
Resolved 25 August 1989
Documentation
Issued 25 August 1989
Resolved
SUBMIT FOR APPROVAL THE FOLLOWING PLANS TO MORGAN CITY OFFICE: (1) OUT ANDINBOARD PLANS; (2) GENERAL ARRANGEMENT; (3) SAFETY AND FIRE CONTROL; (4) HYDRAULIC SYSTEMS; (5) INFORMATION ON AND INSTALLATION OF LEGS.
Condition: Unknown
Due 25 August 1989
Resolved 25 August 1989
Navigation
Issued 25 August 1989
Resolved
INSTALL ADDITIONAL STEERING PUMP AND MOTOR IF READMEASUREMENT IS GREATER THAN 100 GROSS TONS.
Condition: Unknown
Due 25 August 1989
Resolved 25 August 1989