DHT LION

DHT LION is a 2016 tank ship. The Coast Guard has recorded 8 inspections since 2017, most recently in November 2025, along with 2 deficiencies.

Records from 2017 to 2025. Most recent: inspection, 24 November 2025.

Built
2016
Last inspected
24 November 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9722895
V7A3315
1423426
Flag
HONG KONG
Maury page id
psix-1423426

Inspections, by type

…with no type recorded1
Years with a record 7 calendar years (2017–2025)
The 8 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it154487 - Convention (Subpart B), Gross Ton
299629 - Dead Weight, Metric Ton
342613 - Displacement, Metric Ton
107744 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 8

24 November 2025 PSC B · COC-TVE Renew
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8273251
18 June 2024 COC-TVE Renew · Deficiency Check · PSC B · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7936888
14 August 2023 COC-TVE Annual
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7760710
2 July 2022 COC-TVE Renew · PSC B
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7489425
11 October 2019 COE-Administrative
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6833051
20 March 2019 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6636035
16 May 2018 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6416897
8 August 2017 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6229786

Deficiency record · 2

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 June 2024 Resolved
In tankers, electrical equipment, cables and wiring shall not be installed in hazardous location unless it conforms with standards acceptable to the organization. Multiple connections on all cargo pumps have either back shell gasket not properly sealed or wire pulled from back shell not allowing for back shell gasket to make contact. 74 SOLAS(20) 11-1/45.11 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2024
Resolved 8 July 2024
Resolution: Deficiency cleared through class report by [name withheld] Documents for class report.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 14 August 2023 Resolved
Each vessel vapor connection flange face must have a permanent stud projecting outward that has a 12.7 mm (.5mm) diameter and is at least 25.4 mm (1 in) long. It must be located at the top of the flange face, midway between bolt holes and in line with the bolt hole pattern. Vessels vapor stud was removed due to the flange design on the facility equipment not lining up. All four vapor studs on vessel are not permanent and can be removed. 46CFR39.20001(j)
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 June 2024
Resolution: Class attended the vessel on 04OCT2023 to report the rectification of deficiencies. Tech report and Class survey report added to documents.