Records from 2016 to 2024. Most recent: inspection, 8 October 2024.
Inspection history · 16
8 October 2024
PSC B
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8011486
21 February 2024
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7871992
30 August 2023
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7781202
28 March 2022
Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7419787
24 March 2022
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7417866
30 September 2021
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7323650
27 September 2021
Deficiency Check · PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7311862
31 October 2020
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7087564
2 April 2020
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6934448
25 March 2019
ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6636574
22 February 2018
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6359315
11 April 2017
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6122051
9 February 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6085329
9 February 2017
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6101936
12 December 2016
PII Safety Exam · ISPS III Exam
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6055312
24 November 2016
ISPS II Exam · Ballast Water Examination · Joint Vessel Security Verification (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6049164
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 27 September 2021
Resolved
11132 - Life Saving Equipment - Every inflatable lifejacket shall be serviced at intervals not exceeding 12 months. PSCO observed that all 44 inflatable lifejackets on board vessel have not been serviced since August 29, 2020. - 74SOLAS(20)III/20.8.1.1 - 17ac ***changed to 40ac***
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 September 2021
Resolved 29 March 2022
Resolution: 29MAR2022 - Recieved a letter from the class, confirming that the life jackets have been properly inspected as well as have passed inspections.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 September 2021
Resolved
11135 - Maintance of Life Saving Appliances - Maintenance, testing, and inspections of life-saving appliances shall be carried out in a manner having due regard to ensuring reliability of such appliances. PSCO observed that the SART(2) and EPIRB(1) batteries were expiring prior to their next port. - 74SOLAS(20)III/20.3.1 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 27 September 2021
Resolved 29 September 2021
Resolution: Received class report
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 27 September 2021
Resolved
04114 - Emergency source of power (emergency generator) - Each emergency generating set arranged to be automatically started shall be equipped with starting devices approved by the administration. A second source of energy shall be provided. PSCO observed that the seconds means of starting the emergency generator (battery pack) was inoperative. - 74SOLAS(20)II-1/44.2 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 27 September 2021
Resolved 29 September 2021
Resolution: Received class report
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Masters responsibility and authority
Issued 27 September 2021
Resolved
15104 - Masters responsibility and authority - The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additions requirements which may be established by the company. PSCO discovered that vessel Captain and its crew would notify their company of upcoming required maintenance within one month of the lifesaving equipment expiring. Vessel's SMS requires crew to submit requisitions between 3-4 months prior. 74SOLAS(20)IX/3.1 - ISM Code Part A/10.1 - 50abc
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2021
Resolved 29 September 2021
Resolution: Received Class audit
Construction/Loadline › Hull › Double Hull
Issued 9 February 2017
Resolved
9900 -...THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEEDTO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. THE VESSEL MAY HAVE ALLIDED WITH A BRIDGE, AND MAY HAVE RESULTED IN DAMAGE TO THE BRIDGE &/OR THE VESSEL.VESSEL WILL REQUIRE A CLASS SURVEY TO ATTEST THAT THE VESSEL WAS NOT DAMAGED & IS FIT TO PROCEED TO SEA. 17ac
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2017
Resolution: vessel provided class report attesting to the safe condition of the vessel.