Records from 2016 to 2026. Most recent: inspection, 19 January 2026.
Inspection history · 46
19 January 2026
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8298364
24 December 2025
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8287037
20 June 2025
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8163283
26 May 2025
Administrative Inspection · Plan Review (Other than "T") · In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8144144
26 May 2025
Deficiency Check · Damage Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8144660
6 March 2025
MTSA/ISPS Verification · Internal Structural Exam · MARPOL Annex V Examination · COI Inspection · Drydock Exam · MARPOL Annex VI Survey · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8089556
16 June 2024
Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7936276
22 April 2024
COI Inspection · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7888294
11 March 2024
Internal Structural Exam · Underwater Inspection in lieu of Drydock · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7877482
15 September 2023
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7792131
21 May 2023
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7697841
22 March 2023
MTSA/ISPS Verification · Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7660309
1 June 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7465741
3 May 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7443580
29 March 2022
In-Service Inspection · Deficiency Check · Hull Examination · COI Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7420379
17 March 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7416453
5 December 2021
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7389208
15 March 2021
Administrative Inspection · In-Service Inspection · MTSA/ISPS Verification · COI Inspection · Deficiency Check · MARPOL Annex I Examination · Drydock Exam · MARPOL Annex VI Survey · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7155281
19 March 2020
Drydock Extension · Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7055242
1 November 2019
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6846184
9 October 2019
In-Service Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6831282
18 September 2019
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6815350
10 September 2019
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6808676
10 August 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6784862
29 June 2019
Deficiency Check · COI Inspection · MTSA/ISPS Verification · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6732204
12 February 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6627815
1 November 2018
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6572917
27 September 2018
Drydock Exam · Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6550005
5 September 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6533036
17 June 2018
MARPOL Annex I Examination · Deficiency Check · Administrative Inspection · Re-Inspection · MTSA/ISPS Verification · MARPOL Annex VI Survey · COI Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6445450
18 May 2018
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6427985
27 April 2018
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6401174
14 April 2018
Deficiency Check · Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6392494
14 April 2018
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6395957
5 April 2018
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6386209
2 April 2018
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6383779
17 January 2018
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6339081
14 December 2017
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6324367
11 December 2017
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6333595
25 November 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6313923
20 October 2017
Deficiency Check · Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6294077
7 September 2017
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6330142
20 August 2017
Type not recorded
No type recorded · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6249025
4 August 2017
Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6230660
29 July 2017
Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6226495
26 March 2016
Plan Review (Other than "T") · Plan Review "T" Boat · Administrative Inspection · Examination of Repairs · MTSA/ISPS Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6212038
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 January 2026
Resolved
Whenever a vessel is deprived of the service of a member of its complement, and the Master or Person in Charge is unable to find appropriate credentialed personnel to man the vessel, the Master or Person in Charge may proceed on the voyage, having determined the vessel is sufficiently manned for the voyage.
Vessel is authorized to sail short 01 C/E until arrival in Colon, Panama on 23JAN2026.
Action required: 15 - Rectify deficiencies by next port
Due 23 January 2026
Resolved 23 January 2026
Resolution: Received notification that C/E [name withheld] Browning (Mariner ref# [withheld]) is now onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 May 2025
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel reported non-operational stbd engine. Determine cause and complete repairs to satisfaction of Marine Inspector.
Vessel code amendment (60 to 16): Vessel was able to reset ECU and start engine. Provide remote survey technician report completed on 26MAY2025, and tech report of attending technician within 14 days.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 June 2025
Resolution: DNV report received (see documentation), all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Means of recovery of life saving appliances
Issued 13 April 2025
Resolved
If a survival craft is recovered by electric power, the electrical installation, including the electric power-operated boat winch, must meet the requirements in sub-chapter J of this chapter. If a survival craft is recovered by any means using power, including a portable power source,safety devices must be provided that automatically cut off the power before the davit arms or falls reach the stops in order to avoid over-stressing the falls or davits, unless the motor is designed to prevent such over-stressing. MI witnessed a failed test of both davit limit switches.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 April 2025
Resolution: Received objective evidence of davit limit switches operating as designed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 March 2025
Resolved
A main source of electrical power of sufficient capacity to supply all those services mentioned in regulation 40.1.1 shall be provided. This main source of electrical power shall consist of at least two generating sets. #1 SSDG was down for corrective maintenance due to generator not producing the proper voltage.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 April 2025
Resolution: Received objective evidence that the # 1 SSDG is operating as designed.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 6 March 2025
Resolved
Maintenance, testing and inspections shall be carried out based on the guidelines developed by the Organization* and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. MI observed 02 faults on the water mist control panel. The two faults were - system fault and pump unit fault. Prior to departing, faults shall be cleared and system tested to ensure full operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 April 2025
Resolution: Received objective evidence the water mist system is operating as designed and all faults are cleared.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 March 2025
Resolved
Vessels described by 46 CFR 114.110(f) must submit plans to Marine Safety Center and cognizant OCMI, in accordance with 46 CFR 115.700, for the installation and use of monitoring device(s) to ensure the wakefulness of the watchmen required in paragraph (a) of this section. 29 April 2024, Sector San Diego issued an 835 for the vessel not meeting the regulation for Watch Monitoring Device. MI observed that vessel has not installed an approved Watch Monitoring Device. Prior to carrying passengers, vessel shall install an approved Watch Monitoring System.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 May 2025
Resolution: The system was satisfactory installed and tested as per submitted plans.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 29 April 2024
Resolved
Vessel is not adequately equipped with roving watchman alarms. Prove compliance with 46 CFR 122.410(b), or submit plans to the cognizant OCMI, in accordance with 46 CFR 115.700, for the installation and use of monitoring devices to ensure the wakefulness of the vessel's roving watchmen. The watchman alarms must meet the requirements in 46 CFR 122.410(b). Deficiency to be rectified by 29 May 2024.
Cites: 46 CFR 122.410(b) and 46 CFR 114.110(f).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2024
Resolved 25 May 2025
Resolution: New watchman system was installed and tested SAT. This system meets the intent of 46 CFR 122.410(b).
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 22 April 2024
Resolved
Structural fire protection in the following spaces was found to be damaged: Starboard side HVAC (upper deck), Bosun Locker, Grease Trap Space, Portside HVAC (main deck). Repair the damaged structural fire protection to the satisfaction of the attending USCG marine inspector. Deficiency is to be rectified by 06 May 2025 or else this deficiency becomes "Action: 17 - Rectify prior to departure".
Cite: 46 CFR 116.415 and SOLAS 74 II-2:9.2.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2024
Resolved 29 April 2024
Resolution: SFP was replaced where needed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 April 2023
Resolved
MI found temp repairs on both ship service generator prime movers lube oil pump drain lines. Provide evidence of permanent repairs before embarking passengers and departing from the first U.S. port.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 April 2023
Resolution: MI received objective evidence that both SSDGs oil pan temp repairs were removed and permeant repairs were rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 6 April 2023
Resolved
MI found both port and starboard rescue boat davit limit switches not working as designed. Provide evidence of permanent repairs before embarking passengers and departure from the first U.S. port.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 April 2023
Resolution: Limit switches renewed by manufacturer.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 6 April 2023
Resolved
MI found port and starboard rescue boat davit accumulators not holding pressure as designed. Provide evidence of permanent repairs before embarking passengers and departure from first U.S. port. Crew must conduct daily checks on both davits to ensure system has proper pressure to launch rescue boats as designed.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 April 2023
Resolution: Davit accumulators repaired by manufacturer.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 April 2023
Resolved
MI found all relief valves for the ship service pressure vessel not serviced as required by the regulation. Provide evidence of servicing of all relief valves prior to departure of next U.S. port.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 April 2023
Resolution: Vessel provided shipyard documentation stating all ship service air compressor relief valves were tested.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 April 2023
Resolved
MI found automatic closing door 413A (AFT Galley Door) not closing as designed. Door shall be closed when not in use. Provide evidence of permanent repairs before embarking passingers and departure from the first U.S. port.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 April 2023
Resolution: Vessel attached a video of fire door 413A functioning as designed. To resolve this issue, the bottom track needed to be realigned, adjustments were made to the air ram, and additional counterweights were added. It is currently closing as it should.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 April 2023
Resolved
MI found trapped personnel alarm for the freezer not working as designed. Provisde evidence of permanent repairs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 April 2023
Resolution: Upon inspection, the push button contacts were found to be corroded. This was changed out and the push button has been tested multiple times and found to be in designed operating condition.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 3 May 2022
Resolved
Captain reported four 100 person liferafts were not able to be serviced in time. Three 35 person rafts were placed onboard in addition to two 50 person rafts and three 25 person rafts bringing total capacity to 280. 135 persons on port side, 145 persons on starboard.
Vessel's New Construction SOLAS Lifeboat Exemption Request dated 13MAY2016, requires for lifesaving equipment to provide an aggregate capacity for 336% of the total number persons onboard requested at 149 total persons.
Considering life raft capacity of 135 persons port
side and 145 persons starboard side, the maximum
number of persons allowed on board while on an international voyage is constrained to 80 persons.
SOLAS 74 (14)III/21.1.1.1 -16C
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2022
Resolved 15 May 2022
Resolution: Vessel received serviced 100 pax liferafts and were remounted to vessel.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical first aid
Issued 13 April 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 15 May 2022
Resolution: Chief Engineer retired and is no longer on the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 1 April 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Fuel shutoffs valves for the following systems were seized and not operational; 2 boilers, 2 main engines, 2 generators. Demonstrate proper operation of shutoff valves to the satisfaction of attending marine inspector.
74 SOLAS (14) I/11
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 April 2021
Resolved 10 May 2021
Resolution: Witnessed all valves properly closing.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 1 April 2021
Resolved
General arrangement plans shall be permanently exhibited for the guidance of the ship’s officers, showing clearly for each deck the control stations, the various fire sections enclosed by "A" class divisions, the sections enclosed by "B" class divisions together with particulars of the fire detection and fire alarm systems. Plans and booklets shall be kept up to date. Current version of posted fire control plan is not approved.
74 SOLAS (14) II-2/15.2.4.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2021
Resolved 10 May 2021
Resolution: Conducted review/walkthrough of updated fire control plan.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 1 April 2021
Resolved
No ship to which the present Convention applies shall proceed to sea on an international voyage after the date on which the present Convention comes into force unless it has been surveyed, marked and provided with an International Load Line Certificate (ILLC). ILLC is expired. Provide valid ILLC prior to sailing international.
ICCL 1988 Annex A Article 3
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2021
Resolved 10 May 2021
Resolution: Verified current loadline onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Minimum Safe Manning Document
Issued 1 April 2021
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2021
Resolved 10 May 2021
Resolution: Verified vessel is properly manned.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 27 July 2019
Resolved
Ducts with a free cross-sectional area exceeding 0.075 m2 shall be fitted with a fire damper. The switch labeled "Dishwasher Exhaust Damper" is actually the upper end galley hood damper. Provide evidence the dishwasher exhaust is fitted with a damper or is below the size requiring one. - 74 SOLAS (14) II-2/9.7.3.1.2
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2019
Resolved 24 August 2019
Resolution: Vessel provide approved drawings with sizes calulations that proved the duct was below .075 m2
01 - Certificates & Documentation › 011 - Ships Certificates › Continuous synopsis record
Issued 13 July 2019
Resolved
The Continuous Synopsis Record shall list the name of all classification societies with which the ship is classed. The vessel has a classification certificate from Bureau Veritas, but this is not reflected on the CSR. Provide updated CSR. - 74 SOLAS (14) XI-1/5.3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2019
Resolved 27 July 2019
Resolution: Updated CSR (Doc#3) provided.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 13 July 2019
Resolved
The fire damper identification shall placed on any controls required. Fire damper controls in galley and cleaning gear room are mislabeled or unlabeled. Provide proper labeling of all damper controls. - 74 SOLAS (14) II-2/9.7.3.1.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2019
Resolved 24 August 2019
Resolution: All fire dampers have been correctly labled.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 July 2019
Resolved
On passenger ships constructed on or after 1 July 2008, non-load-bearing partial bulkheads which separate adjacent cabin balconies shall be capable of being opened by the crew from each side for the purpose of firefighting. Balcony partitions are bolted into place. Provide means for opening by fire teams.
Action required: 705 - Other - as specified
Due 31 October 2019
Resolved 1 April 2021
Resolution: Verified partitions now fitted with wingnuts for removal.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 29 June 2019
Resolved
Watertight doors 1,2, and 3 failed to operated under stored power. Prove proper operation of watertight doors. - 74 SOLAS (14) II-1/13.7.3.3
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2019
Resolution: Battery connection tightened and batteries recharged. Following recharge, doors tested sat.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 29 June 2019
Resolved
Port side liferaft painter not connected to weak link. Properly attach liferaft for float-free arrangement. - 74 SOLAS (14) III/14.4.1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2019
Resolution: Painter attached to weak link.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 June 2019
Resolved
Fuel leaking from forward first-stage fuel filter on aft generator. Fix fuel leak from filter. - 74 SOLAS (12) II-2/5.1.2
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2019
Resolution: Leak repaired.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 June 2019
Resolved
Combustible storage is not permitted in category 10 electrical lockers. Remove items stored in electrical locker off main dining room port side forward. - 74 SOLAS II-2/9.1.2
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2019
Resolution: Combustible materials removed.
09 - Working and Living Conditions › 092 - Working Conditions › Gas instruments
Issued 29 June 2019
Resolved
The gas detection equipment employed for confined space entry and rescue is out of calibration. Calibrate gas detection equipment. - 74 SOLAS (14) III/19.3.6.2.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2019
Resolved 13 July 2019
Resolution: Provided calibrated gas detection meter.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 June 2019
Resolved
Storage cabinets are not permissable furniture in stairway enclosures. Remove storage locker at the bottom landing of main stairwell. - 74 SOLAS (14) II-2/5.3.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2019
Resolved 13 July 2019
Resolution: Locker removed.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 29 June 2019
Resolved
Penetrations in fire-resistant decks/bulkheads must be of equivalent fire rating. Remove rubber air hoses leading out of the engine room on the starboard side aft that penertrate through fire stops and restore fire rating of decks/bulkheads with approved fire-resistant materials. - 74 SOLAS (14) II-2/
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2019
Resolved 13 July 2019
Resolution: Hoses removed.
08 - Alarms › N/A - No Subsystem › Boiler alarm
Issued 29 June 2019
Resolved
Flame failure alarm on port boiler not operational. Prove proper operation to the CG MI prior to using port boiler. - 74 SOLAS (14) II-1/52
Action required: 705 - Other - as specified
Resolved 27 July 2019
Resolution: Flame failure alarm repaired and tested successfully.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 29 June 2019
Resolved
Several alarm/PA speakers on exterior Lido Deck and Observation Deck inoperable. Prove proper operation of all speakers. - 74 SOLAS (14) III/6.5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2019
Resolved 27 July 2019
Resolution: All speakers repaired.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 29 June 2019
Resolved
Fire control plan shows inaccurate arrangement of engine room smoke/heat detectors, fire door at bottom of vertical corridor, and incorrect toilet placement in spa. Update fire control plan to reflect actual arrangement. - 74 SOLAS (14) II-2/15.2.4.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2019
Resolved 1 April 2021
Resolution: New version of FCP is not approved. Cleared current 835 and issued new to go through approval process.
04 - Emergency Systems › N/A - No Subsystem › Low level lighting in corridors
Issued 29 June 2019
Resolved
Forward crew stairwell and vertical corridor missing required low-location lighting. Install low-location lighting. - 74 SOLAS (14) II-2/13.3.2.5.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2019
Resolved 27 July 2019
Resolution: Low location lighting installed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 June 2019
Resolved
First aid kits onboard missing equipment required under 46 CFR 160.041. Provide first aid kit that contains all required equipment and replaced expired aspirin in conference room kit. - 46 CFR 121.710
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2019
Resolved 13 July 2019
Resolution: All kits restocked with in-date contents.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 29 June 2019
Resolved
No emergency lighting illuminates the landing at the top of the ladder for the engine room emergency escape. Provide emergency lighting at landing during next drydock. - 74 SOLAS (14) II-1/42.4.1.1
Action required: 705 - Other - as specified
Due 31 October 2019
Resolved 28 November 2019
Resolution: Oeprator provided photos
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 29 June 2019
Resolved
Liferaft launching station not illuminated by emergency lighting served by transtiional power. Provide transitional power to liferaft launching station lighting at next drydock. - 74 SOLAS II-1/42.4.1.1
Action required: 705 - Other - as specified
Due 31 October 2019
Resolved 19 November 2019
Resolution: Resolved during 2019 dry dock.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 29 June 2019
Resolved
Insulation on fire boundaries throughout the vessel damaged or missing, including in engine room, elevator machinery space, forward crew stair, and dining room electrical locker. Repair or replace damaged/missing insulation at next drydock.
Action required: 705 - Other - as specified
Due 31 October 2019
Resolved 1 November 2019
Resolution: Resolved during 2019 dry dock.
01 - Certificates & Documentation › 012 - Crew Certificates › Doc evidence for personnel on passenger ships
Issued 29 June 2019
Resolved
Person in charge of passenger mustering on station bill (Senior Steward A) missing evidence of completion of Crisis Management and Human Behavior training. Provide evidence of training completion. - STCW 95 V/2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2019
Resolved 13 July 2019
Resolution: Crisis management certificate of training provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 February 2019
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Vessel expierenced loss of propulsion from PORT main engine. Provide technician report proving satisifactory repairs and operation of PORT main engine. 46CFR115.840
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 March 2019
Resolved 17 March 2019
Resolution: see narrative
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 5 September 2018
Resolved
AIS must be maintained in effective operating condition, which includes the accurate input and upkeep of all AIS data fields. The vessel is transmitting inaccurate AIS data. 33 CFR 164.46(d)(2).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2018
Resolved 25 September 2018
Resolution: Verified correct in VIVS.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 16 July 2018
Resolved
Fire dampers must be accessible from for periodic inspection by means of a hinged or bolted plate in the duct and surrounding bulkhead/deck. Dampers have no inspection ports. Provide ports for inspections of dampers. - 46 CFR 116.(g)(2)/74 SOLAS (14) II-2/9.7.4.6
Action required: 705 - Other - as specified
Due 30 November 2018
Resolved 27 November 2018
Resolution: BV surveyor report states inspection covers created for inspection of dampers unable to be verified at suction/discharge ports.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 16 July 2018
Resolved
For determining the appropriate fire integrity standards to be applied to boundaries between adjacent spaces, such spaces are classified according to their fire risk as shown in categories (1) to (14). Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, it shall be treated as a space within the relevant category having the most stringent boundary requirements. Rooms classified as (10) "mechanical rooms" have been converted into storerooms without the required (13) arrangements or MSC approval. Remove all storage in mechanical rooms or install proper level of fire protection with MSC plan approval. 74 SOLAS (14) II-2/9.2.2.3.2.2
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 July 2018
Resolution: Verified stores were removed from spaces.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 July 2018
Resolved
Furniture in stairway enclosures shall be limited to seating. Lockers of non-combustible material, providing storage for non-hazardous safety equipment required by these regulations, may be permitted. A combustible cabinet full of paper products and a metal locker not labelled to contain safety equipment are present in the aft stair. Remove prohibited furnishings from stairway. - 74 SOLAS (14) II-2/5.3.3
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 July 2018
Resolution: Verified only safety equipment stowed in locker in stairway enclosure.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 1 July 2018
Resolved
The transitional source of electrical power shall power emergency lighting at every embarkation station and over the sides for 30 minutes. The emergency lights for the embarkation station and over the sides are not supplied by transitional power. 74 SOLAS 14 Ch II-1 42.4.1.1
Condition: Improper Installation
Action required: 702 - Prior to embarking on international voyage
Due 31 August 2018
Resolved 27 November 2018
Resolution: BV surveyor report attests to 30 minutes test with 0.3V loss to transitional power supply and proper recharging after test.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 1 July 2018
Resolved
Oil fuel pipes, which, if damaged, would allow oil to escape from a storage or day tank above the double bottom must be fitted with a remote actuated closing device. The remote closing device for the forward fuel tanks is not functional.
74 SOLAS 14 Ch II-2 2.2.3.4
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2018
Resolved 26 August 2018
Resolution: Fuel shut-off tested successfully.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 1 July 2018
Resolved
Emergency lighting for mustering and abandonment shall be tested at each abandon ship drill. Emergency lighting is not tested during each abandon ship drill. 74 SOLAS 14 Ch III 19.3.4.9
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2018
Resolved 26 August 2018
Resolution: Emergency lighting test incorporated into abandon ship drill.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 17 June 2018
Resolved
Every passenger ship shall be provided with means for two-way onscene radiocommunications for search and rescue purposes using the aeronautical frequencies 121.5 MHz and 123.1 MHz from the position from which the ship is normally navigated. The required means are not provided. Provide suitable radios to communicate with aircraft on 121.5 MHz and 123.1 MHz. - 74 SOLAS (14) IV/7.2.
Condition: Improper Installation
Action required: 702 - Prior to embarking on international voyage
Resolved 29 July 2018
Resolution: Verified aircraft radios provided on the operating station.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 17 June 2018
Resolved
All ships of 500 gross tonnage and upwards shall have a gyro compass bearing repeater, or other means, to take bearings, over an arc of the horizon of 360º, using the gyro compass or other means referred to in subparagraph .1. The current arrangement of the alidade provides a ~120 degree blind sector due to mast and inflatables. Arrange gyro bearing repeater to permit the taking of bearings over a 360 degree arc. - 74 SOLAS (14) V/19.2.5.3
Action required: 702 - Prior to embarking on international voyage
Due 31 August 2018
Resolved 27 November 2018
Resolution: BV reports attests to proper installation of new gyro compass repeaters on both sides of brdidge.
Engineering › Steering Gear System › Rudder
Issued 1 May 2018
Resolved
Make port rudder available for inspection at next scheduled dry dock, not later than 31OCT18.
Action required: 705 - Other - as specified
Due 31 October 2018
Resolved 13 November 2018
Resolution: BV report attests to satisfactory rudder testing. Becker Marine Systems report attesting to inspection of both rudders, with note to complete addtional maintenance at next dry-dock. See report in docs. Special note added.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 26 April 2018
Resolved
Complete remainder of MSC approved alterations for escape arrangements, specifically installing break out windows prior to 07NOV18.
Action required: 705 - Other - as specified
Due 1 November 2018
Resolved 4 November 2018
Resolution: MI verified installation of break-out windows while onboard.
Engineering › Steering Gear System › Rudder Stock
Issued 16 April 2018
Resolved
EH01: Vessel requires tug assist with tugs of adequate size, horsepower, and bollard pull for all movements within the Sector Columbia River Area of Responsibility.
Action required: 705 - Other - as specified
Resolved 1 May 2018
Engineering › Steering Gear System › Rudder Stock
Issued 16 April 2018
Resolved
EH02: While passengers are onboard additional engineering/safety rounds must be conducted in the aft steering space and engine room.
Action required: 705 - Other - as specified
Resolved 1 May 2018
Engineering › Steering Gear System › Rudder Stock
Issued 16 April 2018
Resolved
EH03: Vessel may not transit with passengers until a dry dock inspection has been completed and satisfactory repairs have been completed and witnessed by USCG.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2018
Engineering › Steering Gear System › Rudder Stock
Issued 16 April 2018
Resolved
EH04: Submit repair proposal to USCG for damages sustained during grounding.
Action required: 705 - Other - as specified
Resolved 1 May 2018
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 5 April 2018
Resolved
Provide approved PSTP, vessel currently does not have approved PSTP.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2018
Resolved 1 November 2018
Resolution: Vessel not required by Sub K/SOLAS/CVC policy letter
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 17 January 2018
Resolved
Submit revised plans to MSC with compliant escape arrangements as proposed by your ltr dated 29DEC17.
Action required: 705 - Other - as specified
Due 4 March 2018
Resolved 26 February 2018
Resolution: Plans were sent to MSC and have been approved. Alterations still pending.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 17 January 2018
Resolved
Complete MSC approved alterations for escape arrangements. *Alterations to be completed by end of April 2018, except break out windows which were extended to 07NOV2018.
Due 7 November 2018
Resolved 26 April 2018
Resolution: Conducted complete verification of MSC approved fire control plan.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 November 2017
Resolved
Vessel does not have functional stern light and requires installation and operational test IAW 33 CFR 83.23.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 November 2017
Resolved 17 November 2017
Resolution: Operator provided photographic evidence of compliance with 33 CFR 83.23.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 20 October 2017
Resolved
Vessel had insufficient number of child-size PFDs & requires 04 more to meet 10% requirement IAW 46 CFR 117.71(b).
Action required: 705 - Other - as specified
Due 30 October 2017
Resolved 29 November 2017
Resolution: Operator submitted photographic evidence for correction of deficiency.
Electrical › Electric Generation Source (service) › Generator
Issued 4 August 2017
Resolved
The main source of electrical power shall consist of at least two generating sets. The #1 generator is not operational. Repair generator to the satisfaction of the attending CG Marine Inspector prior to international voyages. 74SOLAS(14) Ch II/1 Reg 41.1.1
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 12 August 2017
Resolution: Vessel had technician come on board and troubleshoot finding a relay on the ignition circuit and failed. Relay was replaced and generator tested sat.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 29 July 2017
Resolved
Low location lighting should lead to the exit door handle. Low location lighting does not lead to door handles along escape route. – 74 SOLAS (14) II-2/13.2.5 ref IMO Res. A.752(18)/5.1
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 August 2017
Resolved 26 August 2017
Resolution: LLL added up to door handles.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 29 July 2017
Resolved
Fire doors in galley boundaries must meet the requirements of 74 SOLAS (14) II-2/9.4.1.1.5. The fire door between the galley and dining room is not capable of self closing, remote release, or other operations. – 74 SOLAS (14) II-2/9.4.1.1.5
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 October 2017
Resolved 14 November 2017
Resolution: Marine Inspector attended the vessel and tested its functionality for compliance; received approval letter from MSC.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 29 July 2017
Resolved
Install means to prevent a person from accidentally contacting energized parts in galley panels. – 46 CFR 120.330(i)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 August 2017
Resolved 26 August 2017
Resolution: Protective coverings installed.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 29 July 2017
Resolved
Replace plastic trash cans with non-combustible waste receptacles. – 46 CFR 116.405(i)
Action required: 705 - Other - as specified
Due 29 August 2017
Resolved 26 August 2017
Resolution: Metal trashcans provided.
Accommodation/Occupational Safety › Potable Water System › General
Issued 24 July 2017
Resolved
Lock out Port boiler until repaired and Coast Guard Marine Inspector has witnessed Periodic Safety Test Procedures 46 CFR 61
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 29 July 2017
Resolution: PSTP performed in presence of CGMI
Fire Fighting › Means of Escape › Escape Route Signs
Issued 24 July 2017
Resolved
Install Escape markings to Embarkations Station SOLAS 74 II-2
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 July 2017
Resolution: Escape markings installed
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 24 July 2017
Resolved
Label circuit breakers in distribution panel 46 CFR 120
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 29 July 2017
Resolution: breakers labeled
Electrical › Electrical Distribution System (service) › Ground Indicator
Issued 24 July 2017
Resolved
Investigate and repair ground on 24volt panel on stbd bridge 46 CFR 120
Action required: 705 - Other - as specified
Due 8 August 2017
Resolved 26 August 2017
Resolution: Ground isolated and repaired
Fire Fighting › Means of Escape › Doorways
Issued 24 July 2017
Resolved
Repair Fire Screen Doors (split) on Lounge Deck for complete and timely closing 46 CFR 118
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 July 2017
Resolution: Sequencing devices installed and tested sat.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 24 July 2017
Resolved
Submit updated Fire Safety Plan 46 CFR 116
Action required: 705 - Other - as specified
Due 18 January 2018
Resolved 18 January 2018
Resolution: Vessel owner submitted new Fire Safety Plan to MSC.
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 24 July 2017
Resolved
Post Survival Craft launching placard 46 CFR 122
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 July 2017
Resolution: Launching placards posted
Operations/Management › Drills/Instruction › Abandon Ship
Issued 24 July 2017
Resolved
Perform Passenger muster witnessed by Sector Juneau Marine Inspector 46 CFR 122
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 July 2017
Resolution: CGMI's witnessed pax muster
Stability › Incline Test › General
Issued 24 July 2017
Resolved
Perform stability test and loadline in accordance with approved procedures 46 CFR 114
46 CFR 115
Action required: 705 - Other - as specified
Due 18 January 2018
Resolved 18 January 2018
Resolution: ABS Houston issued new Stability letter.
Stability › Incline Test › General
Issued 24 July 2017
Resolved
Provide proof of valid loadline and stability issued by ABS for carriage of passengers 46 CFR 114 46 CFR 115
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 July 2017
Resolution: Stability documents issued
Fire Fighting › Means of Escape › Escape Route Signs
Issued 24 July 2017
Resolved
Install photoluminescent exit signs in lower 300 mm of bulkhead in accordance with guidance of low lighting on Passenger Ships IMO circular A.752(18)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 July 2017
Resolution: PL strips installed
Documentation › Certificates/Documents › Stability Letter
Issued 24 July 2017
Resolved
Provide proof of compliance with all requirements listed in the Stability Letter issued by ABS dated on July 28, 2017 Inspector in Juneau 46 CFR 170
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 July 2017
Resolution: Stability letter issued.