Records from 2013 to 2023. Most recent: inspection, 1 November 2023.
Inspection history · 21
1 November 2023
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7819012
9 August 2023
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7770050
9 August 2023
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7776685
17 April 2023
In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7672012
8 September 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7553990
12 April 2022
Drydock Exam · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7440113
8 September 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7307539
12 April 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7172240
8 April 2021
Deficiency Check · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7172239
5 April 2021
Construction Oversight · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7169194
8 September 2020
Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7050416
12 December 2019
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6885632
30 October 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6845555
3 October 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6827413
15 May 2019
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6704977
6 November 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6576081
21 January 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6342538
6 October 2017
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6284198
8 June 2017
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6170093
15 May 2017
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6170045
9 November 2016
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6046884
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 September 2022
Resolved
The master and crew will be familiar with the content and have mounted at the operating station emergency instructions for fire, heavy weather, or man overboard. Emergency instructions not posted at the operating station. Provide emergency instructions at operating station.
46 CFR 185.510
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2022
Resolved 20 September 2022
Resolution: Emergency instructions posted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 September 2022
Resolved
A space containing diesel machinery must be fitted with at least two ducts to furnish natural or powered supply and exhaust ventilation. Only 01 Exhaust/supply duct furnished in each engine room. Supply looks like it may have been supplied from pipe that leads to nowhere. Provide second supply/exhaust for both port and starboard engine rooms.
46 CFR 182.465
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2022
Resolved 8 August 2023
Resolution: Vessel destroyed in Lahaina Wildfire.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 September 2022
Resolved
A fire pump must be capable of both remote operation from the operating station and local operations at the pump. Fire pump operation not at operating station or locally in engine room. Provide remote operation from the operating station and local operation from engine room.
46 CFR 181.300(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2022
Resolved 2 November 2022
Resolution: Local and remote ops from operating station provided.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 8 September 2021
Resolved
A vessel on Limited Coastwise route must carry - six hand red flare distress signals approved IAW Sub Q and six hand orange smoke distress signals (may be substituted for a hand red flare distress signal) IAW Sub Q. Vessel only had (08) hand red flare distress signals. Obtain (04) more hand red flare distress signals.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 September 2021
Resolution: Owner provided (04) more hand red flare distress signals.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 September 2021
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The port side fire extinguisher near the bar and fire extinguisher at the operating station were worn and rusting at their base. Obtain (02) new fire extinguishers as required by your COI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 September 2021
Resolution: Owner provided (02) new fire extinguishers.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 8 September 2021
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have onboard a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Hydrostatic release was missing. Install Hydrostatic release for vessel EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 September 2021
Resolution: Owner installed required hydrostatic release.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 September 2021
Resolved
A number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided. The COI indicates (09) child size and (88) adult life jackets are required. (01) child size life jacket and (01) adult sized life jacket were condemned. The vessel currently has (08) child size and (89) adult life jackets. Vessel cannot carry more than (08) children until additional required child size life jacket is placed onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 September 2021
Resolution: Owner obtained new child life jacket.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 8 September 2021
Resolved
A life float must be approved under approval series 160.027 or other standard specified by the Commandant. Overall integrity of the life float is good, however, inspection identified approximately (09) small patch areas. Make approved repairs and provide documentation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2021
Resolved 13 September 2021
Resolution: Vessel operator affected repairs.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 8 September 2021
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date nautical publications. US Coast Pilot and Light List was out of date. Download latest version to vessel software(i.e. 53rd/2021 edition).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2021
Resolved 13 October 2021
Resolution: Nav pubs provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 September 2021
Resolved
Vessel has the following COI endorsement for Sector Honolulu Work Instruction 31, "If the provisions of work instruction 31 are met, the required deckhand(s) may enter the water while moored or at anchor during in-water passenger activities". Crewmembers do not have valid first aid/CPR training as required in Sector Honolulu Snorkel Dive Questionnaire. Vessel must do one of the following options until crewmembers have valid first aid/CPR training: 1) Cease putting the deckhand in the water as a lifeguard or 2) Put a third deckhand on the vessel to ensure (02) deckhands are onboard at all times as required by vessel COI manning section.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 13 October 2021
Resolution: First aid for crew provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 September 2021
Resolved
Sail Rigging Preventative Maintenance Plan (PMP) not updated with all current configurations. In PMP provide sail plan, full rigging inventory, and inspection regime. Ensure all to log all inspections in accordance with vessel PMP. Keep copy of PMP on board vessel at all times and submitted revised version of PMP to [name withheld].
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2021
Resolved 28 December 2021
Resolution: PMP Provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 September 2021
Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and Supervisory personnel must receive at least 60 minutes of training. Provide proof of completed EAP training for all personnel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2021
Resolved 13 October 2021
Resolution: EAP Training provided.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 September 2021
Resolved
The fire pump outlet must be fitted with a pressure gauge. At the time of the test, it was evident both port/stbd fire pumps provided sufficient pressure to successfully fight fires onboard the vessel. However, both port/stbd pressure gauges were inoperable. Replace with working pressure gauges and provide video evidence.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2021
Resolved 13 October 2021
Resolution: Gauges installed and pressure test completed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 April 2021
Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and Supervisory personnel must receive at least 60 minutes of training. Provide proof of completed EAP training for all personnel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2021
Resolved 6 May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 September 2020
Resolved
Ring life buoy life and body deteriorated. Provide new life ring buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2020
Resolved 21 December 2020
Resolution: New ring provided.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 9 September 2020
Resolved
Life float line for floating water light is approximately 6 ft. Provide line that is at least 18 feet.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2020
Resolved 23 October 2020
Resolution: Life Float lines extended.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 September 2020
Resolved
Visual bilge alarm at helm for starboard forward compartment not working. Provide operational visual bilge alarm at helm for starboard forward compartment.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 October 2020
Resolution: Light operating.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 9 September 2020
Resolved
Compass light not operational. Provide compass light.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 December 2020
Resolution: Compass light operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 September 2020
Resolved
Natural ventilation for engine room port side not closing using remote closure device. Make natural ventilation operational.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 November 2020
Resolution: Vent closure operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 September 2020
Resolved
Port engine room fuel line from tank to remote fuel shut off showing heavy corrosion. Replace corroded piping.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2020
Resolved 30 November 2020
Resolution: Piping replaced.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 9 September 2020
Resolved
Cracks located in FRP around hatches, engine room corners, and other spaces. Provide plan for locating, marking, and repairing all cracks in FRP. NVIC 8-87. Repairs to be completed at next drydock.
Action required: 705 - Other - as specified
Due 8 October 2020
Resolved 20 April 2021
Resolution: Repaired 17 cracks on the interior spaces of the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 9 September 2020
Resolved
Port and starboard fire main gauges not working. Provide operational gauges for fire mains.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2020
Resolved 30 November 2020
Resolution: Gauges operational.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 9 September 2020
Resolved
Deck cracking where port side forward crossbeam meets the deck. Make repairs to deck in accordance with NVIC 8-87.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2020
Resolved 8 February 2021
Resolution: Crack was superfficial.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 October 2019
Resolved
Stbd fire pump performance was unsatisfactory. Prove satisfactory operation in accordance with 46 CFR 176.810.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2019
Resolved 12 November 2019
Resolution: Fire pump operated satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 October 2019
Resolved
Stbd fire hose contained foreign material impeding flow. Renew hose in accordance with 46 CFR 176.810.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2019
Resolved 30 October 2019
Resolution: New hose provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 3 October 2019
Resolved
Port light deadcovers were missing fasteners. Provide fasteners in accordance with 46 CFR 179.350.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2019
Resolved 30 October 2019
Resolution: Fasteners installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 October 2019
Resolved
Rigging Preventative Maintenance Plan was not provided. Provide in accordance with 46 CFR 176.840.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2019
Resolved 12 November 2019
Resolution: Rigging Preventative Maintenance Plan provided.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 6 October 2017
Resolved
Missing one childs Life Jacket
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 October 2017
Resolution: Childs life jacket provided.
Operations/Management › Vessel Activity › Underway
Issued 5 June 2017
Resolved
Vessel needs to complete satisfactory sea trials under sail propulsion witnessed by an attending USCG Marine Inspector. 46 CFR 176.840
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 June 2017
Resolved 9 June 2017
Resolution: Satisfactory sea trials under sail conducted.
Lifesaving › Hand Flares › Storage
Issued 9 November 2016
Resolved
Storage box not adequate.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2016
Resolution: Vessel purschaed adequate storage box.
Engineering › Bilge Water Management System › Pump
Issued 9 November 2016
Resolved
Port Engine room bilge pump not working.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2016
Resolution: Bilge pump was replaced.