MAURY USCG vessel records
← All vessels

THE JUDGE

THE JUDGE is a 2016 tank ship. The Coast Guard has recorded 15 inspections since 2018, most recently in February 2026, along with 3 deficiencies and 1 operational control.

Records from 2018 to 2026. Most recent: inspection, 26 February 2026.

Built
2016
Last inspected
26 February 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9755725
1424827
Flag
MARSHALL ISLANDS
Maury page id
psix-1424827

Inspections, by type

…with no type recorded3
Years with a record 8 calendar years (2018–2026)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it37770 - Dead Weight, Ton
28013 - Convention (Subpart B), Gross Ton
8403 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 15

26 February 2026 COC-CHEM & TVE Annual · PSC B · COE-Administrative
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8316865
22 March 2025 Administrative Inspection · COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8097863
11 February 2025 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8077775
17 July 2023 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7745258
14 July 2023 COC-TVE Annual · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7742291
22 May 2023 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7694663
1 September 2022 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7548804
23 March 2022 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7417278
10 August 2021 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7281796
7 June 2021 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7218708
22 September 2020 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7062770
31 August 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6805646
27 August 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6796182
7 July 2019 ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6739566
7 June 2018 COC-TVE Renew · ISPS II Exam · Ballast Water Examination · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6434000

Deficiency record · 3

07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 11 February 2025 Resolved
Firefighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed the pilot line disconnected from 03 CO2 cylinders, rendering them inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2025
Resolved 13 February 2025
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 14 July 2023 Resolved
For tankers of 20,000 tones deadweight,,,,the potection of the tank shall be achieved by IGS. Inspector was not able to test IGS due to inoperability. Vessel shall not carry cargoes with a flashpoint under 60 degrees C.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 19 July 2023
Resolved 17 July 2023
Resolution: Received report from class BV. Vessel replaced the valve positioner electronic control valve on the IGS. IGS was run and tested satisfactorily.
Engineering › Lubricating Oil Service System › Pump Prime Mover
Issued 7 June 2018 Resolved
Means shall be provided to control leaks of flammable liquids. PSC Officer noted multiple valves leaking in pump rooms #1 & #2, specifically but not limited to those labled 55, 85, co 136, 85, 054, 10152, 012, 020, 2P041, piping & valves in pump room are covered with insulation, which is soaked through in multiple locations due to leaking valves.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2018
Resolved 21 June 2018
Resolution: Rec'd before and after photos from ship showing indicated valves with new lagging in place.

Ownership record