Records from 2018 to 2026. Most recent: inspection, 16 June 2026.
Inspection history · 84
16 June 2026
Explosive Handling Operation-Commercial
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8405754
21 April 2026
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 8353228
14 January 2026
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8296393
12 January 2026
ACP Annual Oversight · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8286153
22 October 2025
Deficiency Check
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 8256813
9 September 2025
Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8230601
4 August 2025
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8201711
4 August 2025
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8202495
26 February 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8085295
21 February 2025
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8083049
14 February 2025
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8082397
6 January 2025
Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8059188
29 October 2024
MTSA/ISPS Verification · Deficiency Check · In-Service Inspection · ACP COI Oversight · Administrative Inspection · Re-Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8029572
13 June 2024
Administrative Inspection · COI Inspection · ACP Drydock Oversight
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 8012199
22 March 2024
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7886186
12 March 2024
MTSA/ISPS Verification · ACP COI Oversight · Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7871037
16 January 2024
Explosive Handling Operation-Commercial
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7849543
7 June 2023
Explosive Handling Operation-Commercial
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7713115
21 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7654431
15 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7651512
15 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7651520
15 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7651524
15 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7651526
15 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7651528
15 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7651535
15 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7651541
15 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7651547
15 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7651572
13 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7650178
13 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7650189
13 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7650198
13 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7650227
13 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7650238
13 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7650252
13 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7650269
13 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7650276
13 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7650293
13 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7650306
13 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7650328
13 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7650364
13 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7650402
13 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7650423
13 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7650429
13 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7650446
13 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7650453
13 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7650457
13 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7650461
10 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7649137
21 February 2023
Damage Survey · ACP Annual Oversight · Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7625940
6 February 2023
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7639936
14 September 2022
Explosive Handling Operation-Commercial
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7571837
9 August 2022
Explosive Handling Operation-Commercial
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7534910
22 June 2022
Explosive Handling Operation-Commercial
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7486147
2 June 2022
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7587958
25 May 2022
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7458661
30 March 2022
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7453475
7 March 2022
MTSA/ISPS Verification · Annual Inspection · ACP Annual Oversight · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7407662
31 January 2022
Underwater Inspection in lieu of Drydock
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7385613
19 August 2021
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7291785
15 June 2021
Explosive Handling Operation-Commercial
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7226652
10 June 2021
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7221034
27 April 2021
Annual Inspection · ACP Annual Oversight
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7184262
7 December 2020
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7107761
11 November 2020
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7093592
7 September 2020
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7047224
29 June 2020
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6990086
15 June 2020
Annual Inspection · ACP Annual Oversight
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6977313
10 May 2020
Examination of Repairs · Plan Review (Other than "T") · Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6951132
21 April 2020
Explosive Handling Operation-Commercial
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7009924
16 April 2020
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6939785
3 April 2020
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6935223
30 December 2019
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6880735
24 December 2019
Explosive Handling Operation-Administrative
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6886946
29 October 2019
Explosive Handling Operation-Commercial
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6844173
29 October 2019
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6844214
28 October 2019
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6843313
15 October 2019
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6835116
24 September 2019
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6816305
6 August 2019
Administrative Inspection · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6795553
1 August 2019
Re-Inspection · ACP COI Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6770057
28 May 2019
Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6697274
13 May 2019
Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6683300
4 May 2019
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6676678
1 August 2018
Initial Certification · ISM Oversight · Construction Oversight · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6648379
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 February 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. On 15FEB2025, vessel crew found that auxiliary boiler blowdown overboard discharge elbow between valve and hull had a leak. Damage is below waterline. Temporary repairs made by crew. Hazardous condition was not reported to OCMI until 21FEB2025. Vessel is currently underway to LA/LB. Make permanent repairs to satisfaction of RO in the Port of LA/LB.
74 SOLAS (20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 4 March 2025
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 21 February 2025
Resolved
The safety management system should ensure: compliance with mandatory rules and regulations. Vessel suffered damage to an overboard discharge under the waterline on 15FEB2025. Report was not made to FEACT until 21FEB2025 and not immediately after addressing the resultant safety concerns as required by 46 CFR 4.05-1. Vessel made temporary repair, continued operation to next port, conducted cargo operations in the Port of Ningbo, PRC and then got underway again before reporting to USCG. Perform internal ISM audit due determine root cause and report CAR to ISM RO and USCG. Due 22MAR2025.
74 SOLAS (20) IX/2.1.3
ISM A/1.2.3.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2025
Resolved 4 March 2025
Resolution: ISM Audit completed by ABS and CAR issued by company
09 - Working and Living Conditions › 092 - Working Conditions › Gas instruments
Issued 30 October 2024
Resolved
The detection equipment shall be located where gas may accumulate and in the ventilation outlets. Gas dispersal analysis or a physical smoke test shall be used to find the best arrangement. The fuel preparation room gas detectors are not located in the ventilation outlet.
SOLAS II-1/57
IGF Code 15.8.4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2024
Resolved 21 November 2025
Resolution: In coordination with company records, MSC, FEACT Lead Inspector, and LA/LB Lead Inspector the deficiency has been cleared. See narrative.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 October 2024
Resolved
Bunkering lines shall be arranged for inerting and gas freeing. When not engaged in bunkering, bunkering pipes shall be free of gas, unless the consequences of not gas freeing are evaluated and approved. KAIMANA HILA is to provide detailed procedures of how bunker line arrangement complies with 8.5.5. Vessel was found not in compliance with 8.5.5, bunker line was not free of gas post bunkering.
SOLAS II-1/57
IGF Code 8.5.5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2024
Resolved 21 November 2025
Resolution: In coordination with company records, MSC, FEACT Lead Inspector, and LA/LB Lead Inspector the deficiency has been cleared. See narrative.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 October 2024
Resolved
Prior to conducting bunkering operations, pre-bunkering verification including, but not limited to the following
shall be carried out and documented in the bunker safety
checklist: operation of fixed gas and fire detection
equipment KAIMANA HILA does not have appropriately rated
equipment to test fire detection equipment in hazardous
spaces.
SOLAS II-1/57
IGF Code 18.4.3.1.2
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 November 2024
Resolution: Received proper testing equipment.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 30 October 2024
Resolved
The material of the bulkheads of the tank connection space shall have a design temperature corresponding with that lowest temperature it can be subject to in a probably maximum leakage scenario. The tank connection space shall be designed to withstand the maximum pressure build up during such a leakage. provide prescriptive detail to Administration on the probable maximum leakage scenario in accordance with 6.3.8
SOLAS II-1/57
IGF Code 6.3.7
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2024
Resolved 21 November 2025
Resolution: In coordination with company records, MSC, FEACT Lead Inspector, and LA/LB Lead Inspector the deficiency has been cleared. See narrative.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 30 October 2024
Resolved
Fuel preparation rooms shall be located on an open deck, unless those rooms are arranged and fitted in accordance with the regulations of this Code for tank connections spaces. provide prescriptive detail to Administration on the probable maximum leakage scenario in accordance with 6.3.8.
SOLAS II-1/57
IGF Code 5.8,
6.3.7
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2024
Resolved 21 November 2025
Resolution: In coordination with company records, MSC, FEACT Lead Inspector, and LA/LB Lead Inspector the deficiency has been cleared. See narrative.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 12 March 2024
Resolved
The conditions of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will maintain fit to proceed to sea without danger to the ship. Steering system has excessive oil leaking out of lower actuator seal.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 31 March 2024
Resolved 12 March 2024
Resolution: Received class report attesting to proper repairs.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 12 March 2024
Resolved
All fire dampers shall be capable of manual operation. The dampers shall have a direct mechanical means of release or, alternatively, be closed by electrical, hydraulic or pneumatic operation. Port side #3 ventilation damper did not operate properly.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 March 2024
Resolved 12 March 2024
Resolution: Vessel made proper repairs to equipement.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 21 February 2023
Resolved
Each vessel must carry a category-1, 406MHz satellite EPIRB meeting the requirements of 47CFR80.
MI observed expired NOAA registration document. Vessel submitted the required information to obtain a valid EPIRB registration. MI received electronic evidence via text message confirming updated document.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 21 February 2023
Resolved 21 February 2023
Resolution: MI received electronic evidence of new EPIRB registration.
01 - Certificates & Documentation › 013 - Documents › Certificate or documentary evidence of financial security relating to shipowners liability
Issued 7 March 2022
Resolved
The COFR operator must apply for and ensure the vessel is covered at all times by a current COFR.
Vessel must show proof of a valid COFR prior to movement.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 7 March 2022
Resolved 8 March 2022
Resolution: Original COFR expired 04MAR22, payment made 07Mar22 and validated 08Mar22.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 7 March 2022
Resolved
Stairways and lift trunks which penetrate more than one deck shall be surrounded by atleast A-0 class bulkheads and be protected by self closing doors. Doors to main stairway on decks: U,A,B,and D do not close properly.
Provide class report with finding number for action.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2022
Resolved 9 March 2022
Resolution: doors repaired and closing properly.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 27 April 2021
Resolved
Expired medicine and medical supplies were found on-board without adequate replacements. Provide replacements for expired medicine and medical supplies.
ILO 147 (26)/ PWSA 33 USC 1223(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 4 May 2021
Resolution: Expired medicines and medical supplies were replaced onboard.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 10 May 2020
Resolved
Ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of of a classification society which is recognized by the Administration. Vessel has a 3 meter crack at frame 108 on the port side shell. Make repairs in accordance with class approved repair plan and conduct failure analysis
Action required: 17 - Rectify deficiencies prior to departure
Due 10 May 2020
Resolved 14 May 2020
Resolution: Repairs are completed as per class approved repair plan.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 May 2020
Resolved
Conduct and submit to the USCG a failure analysis report for the craacking at frame 108 port side.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2020
Resolved 29 May 2020
Resolution: Received failure analysis.structur