← All vessels
CHAMPION III
CHAMPION III is a 2010 public freight. The Coast Guard has recorded 16 inspections since 2017, most recently in April 2024, along with 59 deficiencies and 4 operational controls.
Records from 2017 to 2024. Most recent: operational control imposed, 3 April 2024.
- Built
- 2010
- Last inspected
- 1 April 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 59 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9550656 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
HO7207
1425794
Flag
PANAMA
—
Maury page id
psix-1425794
Inspections, by type
…with no type recorded2
Years with a record
8 calendar years (2017–2024)
The 16 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it1097 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 16
1 April 2024
Deficiency Check · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7886905
31 March 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7887742
9 March 2024
PSC B · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7875589
13 September 2023
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7790985
20 August 2023
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7770604
29 July 2022
Deficiency Check · Administrative Inspection · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7518800
6 January 2021
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7120442
3 June 2020
PSC B
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6967047
17 February 2020
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6910667
10 July 2019
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6744339
28 June 2018
PI Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6457475
5 December 2017
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6318326
2 November 2017
Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6299127
30 October 2017
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6297420
12 July 2017
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6206714
12 January 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6069154
Deficiency record · 59
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 1 April 2024
Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. For the purpose of this regulation the requirements of the Code shall be treated as mandatory. The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company. The company and the ship shall comply with the requirements of the International Safety Management Code… In meeting these requirements, the company should ensure that: any non-conformity is reported, with its possible cause, if known. Upon boarding the vessel, PSCOs were notified by the crew that the forward cargo loading/unloading ramp was broken, and it was found to be inoperable by the crew at approximately 0800 of 31MAR2024 and PSCOs were notified at 1500 on 31MAR2024. When asked what the non-conformity reporting procedures were – no crew members knew what measures to take per the vessel’s safety management system (SMS). Subsequently, the crew was unable to produce the vessel’s SMS in its entirety. The company should ensure that the master is: ... fully conversant with the company’s safety management system (SMS). The master articulated to the PSCOs that he was unfamiliar with the vessel’s SMS and he was unable to access an electronic or hard copy of the SMS. The technical and/or operational nature of the deficiencies noted below provide objective evidence of a serious failure of the implementation of the ISM Code. An external ISM audit report, satisfactory to the Coast Guard, must be submitted prior to clearance of this deficiency.
74 SOLAS (20) IX/3.1
ISM Code A
10.1
10.2.2
6.1.2
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 1 April 2024
Resolved
Failure of seafarers to hold a certificate, to have an
appropriate certificate, to have a valid dispensation or to
provide documentary proof that an application for an
endorsement has been submitted to the Administration in
accordance with regulation I/10, paragraph 5. Vessel’s
second engineer does not have a Flag State endorsement, with
no proof of application for one.
STCW Reg I/4 2.1
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 1 April 2024
Resolved
Failure of seafarers to hold a certificate, to have an
appropriate certificate, to have a valid dispensation or to
provide documentary proof that an application for an
endorsement has been submitted to the Administration in
accordance with regulation I/10, paragraph 5. The Captain
does not have a GMDSS Radio Operator Certificate of
Competency.
STCW Reg I/4 2.1
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 1 April 2024
Resolved
Every crew member with assigned emergency duties shall be
familiar with these duties before the voyage begins. During
the fire drill, while referencing the vessel’s muster list,
PSCOs observed multiple crew members did not have knowledge
of their emergency duties. For example, crew members could
not internally find their fighting equipment such as SCBA.
Additionally, during the abandon ship drill, multiple crew
members did not know what items they were required to bring
to the muster location.
74SOLAS(20)
III/19.2.1
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 1 April 2024
Resolved
An embarkation ladder complying with the requirements of ...
shall be provided at each embarkation station or at every
two adjacent embarkation stations for survival craft
launched down the side of the ship. Vessel’s crew reported
to the PSCO that in the event of an abandon ship, they jump
off the ship into the water near the life raft after it is
inflated. The instructions posted on the bulkhead in the
nearby vicinity of the life raft area directed personnel to
use a ladder to embark the life raft. The crew was not aware
that the instructions referenced using a ladder nor could
they locate the embarkation ladder.
74SOLAS(20) III/11.7
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 1 April 2024
Resolved
The main steering gear and rudder stock shall be: Capable of
putting the rudder over from 35° on one side to 35° on the
other side with the ship at its deepest seagoing draught...
The vessel is fitted with two rudders, with only one angle
indicator present in the steering gear space. This rudder
angle indicator is not capable of moving to a position
greater than approximately 28° in either direction.
74SOLAS(04)
II-1/29.3.2
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 April 2024
Resolved
Nautical charts and nautical publications, such as sailing
directions, lists of lights, notices to mariners, tide
tables and all other nautical publications necessary for the
intended voyage, shall be adequate and up to date. The
charts onboard are not updated with the most up-to-date
chart corrections (chart corrections have not been updated
since 2022). PSCOs questioned the crew about how they
perform updates to the charts. PSCOs were advised that it
is the 2nd Officer’s responsibility to carry out these
corrections. The 2nd officer was not aware of “Notice to
Mariners” nor how to perform the needed chart corrections.
74SOLAS(20) V/27
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 April 2024
Resolved
Fire hoses shall be of non-perishable material approved by
the Administration and shall be sufficient in length to
project a jet of water to any of the spaces in which they
may be required to be used. Upon testing of the main and
emergency fire pump, the fire hose on the port side, second
deck, ruptured during operation.
74SOLAS(20)
II-2/10.2.3.1.1
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 1 April 2024
Resolved
The electrical power available shall be sufficient to supply all those services that are essential for safety in an emergency, ... . The emergency source of electrical power shall be capable, ... , of supplying simultaneously at least the following services for the periods specified hereinafter. C/E stated that emergency generator was only
capable of providing power to the GMDSS batteries and that
the ship did not have any other reserve source of electrical
power. C/E attested that the emergency source of power does
not meet the on-load power supply requirements set forth in
regulation 43.
74SOLAS(20)
II-1/43.2
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 1 April 2024
Resolved
Two spare charges shall be provided for each required
breathing apparatus. PSCOs observed only 01 spare charge for
the required breathing apparatuses onboard.
74SOLAS(20)
II-2/10.10.2.5
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 April 2024
Resolved
Before the ship leaves and at all times during the voyage,
all life-saving appliances shall be in working order and
ready for immediate use. PSCO’s observed an inoperable
lifebuoy light filled with water on the starboard side of
the vessel.
74SOLAS(20) III/20.2
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 April 2024
Resolved
Maintenance, testing and inspections shall be carried out
based on the guidelines developed by the Organization and in
a manner having due regard to ensuring the reliability of
fire-fighting systems and appliances. PSCOs observed that
all portable extinguishers onboard the vessel had not been
inspected in accordance with MSC.1/Circ.1432 for the month
of March.
74SOLAS(20)
II-2/14.2.2.1
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 1 April 2024
Resolved
A satellite emergency position-indicating radio beacon ...
shall be: capable of floating free if the ship sinks...
PSCOs found a discrepancy with the port side EPIRB
hydrostatic release. The hydrostatic release is dated to
expire Oct2026. The hydrostatic device itself also states,
“dispose after two years from install date.” The marked
expiration date exceeds the manufacturer’s recommendation.
74SOLAS(20)
IV-7.1.6.4
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 1 April 2024
Resolved
Efficient guard rails or bulwarks shall be fitted to all
exposed parts of the freeboard and superstructure decks.
PSCO observed a broken guard rail near the rescue boat.
ICLL 66 Reg. 25.2
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo Securing Manual
Issued 1 April 2024
Resolved
All cargoes, other than solid and liquid bulk cargoes, cargo
units and cargo transport units, shall be loaded, stowed and
secured throughout the voyage in accordance with the Cargo
Securing Manual approved by the Administration. … The Cargo
Securing Manual shall be drawn up to a standard at least
equivalent to relevant guidelines developed by the
Organization. Vessel’s crew could not produce the Cargo
Securing Manual.
74SOLAS(20) VI/5.6
01 - Certificates & Documentation › 013 - Documents › SOPEP
Issued 1 April 2024
Resolved
Every oil tanker of 150 gross tonnage and above and every
ship other than an oil tanker of 400 gross tonnage and above
shall carry on board a Shipboard Oil Pollution Emergency
Plan approved by the Administration. Vessel’s crew could not
produce the Shipboard Oil Pollution Emergency Plan.
MARPOL I/37.1
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 1 April 2024
Resolved
The vessel owner or operator must ensure they maintain one
English language copy of the VRP... onboard the vessel.
Vessel’s crew could not produce a paper nor electronic copy
of the Vessel Response Plan onboard.
33 CFR 155.5030(g)(1)
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 1 April 2024
Resolved
The transfer procedures required by 33 CFR 155.720 must be:
Available for inspection by the COTP or OCMI whenever the
vessel is in operation. Vessel did not have transfer
procedures onboard.
33 CFR 155.720(a)
14 - Pollution Prevention › 146 - MARPOL Annex VI › Bunker delivery notes
Issued 1 April 2024
Resolved
The bunker delivery note shall be kept onboard the ship...It
shall be retained for a period of 3 years after the fuel oil
has been delivered onboard. PSCO only observed bunker
delivery notes dating back to 2022.
MARPOL VI/18.6
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 1 April 2024
Resolved
The garbage record book along with the receipts obtained
from reception facilities shall be kept onboard the ship or
the fixed floating platform, and in such a place to readily
available for inspection at all reasonable times. Vessel’s
crew was unable to produce any garbage receipts.
MARPOL V/10.3.5
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 1 April 2024
Resolved
The master of the ship shall be supplied with such reliable
information as is necessary to enable him by rapid and
simple processes to obtain accurate guidance as to the
stability of the ship under varying conditions of service.
This information shall include: ... The master of the ship
shall be supplied with such reliable information as is
necessary to enable him by rapid and simple processes to
obtain accurate guidance as to the stability of the ship
under varying conditions of service. The Master of the
vessel advised PSCOs that he was not aware of the vessel
having a stability booklet and also communicated he would
not be able to do stability calculations if needed.
74SOLAS(04)
II-1/25-8.1
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 1 April 2024
Resolved
The deck line is a horizontal line 300mm in length and 25mm
in in breadth. It shall be marked amidships on each side of
the ship... PSCO’s observed that the deck line on the
starboard side of the vessel was missing.
ICLL 66 Reg. 4
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 1 April 2024
Resolved
All ships of 300 gross tonnage and upwards... and passenger
ships irrespective of size shall be fitted with: An echosounding
device, or other electronic means, to measure and
display the available depth of water. PSCO’s observed that
the echo depth sounder was inoperable.
74SOLAS(20)
V/19.2.3.1
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 April 2024
Resolved
...Fire hoses shall have a length of at least 10m, but not
more than: 15m in machinery spaces. PSCO’s observed 02 fire
hoses in the engine room that were 30 meters in length.
74SOLAS(20)
II-2/10.2.3.1.1.1
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 1 April 2024
Resolved
Except as provided in paragraphs (b) and (c) of this section
no person may cause a vessel to enter into or get underway
on the navigable waters of the United States unless no more
than 12 hours before entering or getting underway, the
following equipment has been tested ... The vessel had pre-arrival checks written in the logbook, however, when
questioned about the log entries, the ship’s Navigation
Officer and Master had no idea what the entries in the
logbook meant and did not know where to find the vessel's
procedures for pre-arrival checks.
33 CFR 164.25(a)
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 1 April 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
74SOLAS(20)
I/11(a)
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 9 March 2024
Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. For the purpose of this regulation the requirements of the code shall be treated as mandatory. The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company. The technical and/or operational nature of the deficiencies noted below provide objective evidence of a serious failure of the implementation of the ISM Code. An external ISM audit report, satisfactory to the Coast Guard, must be submitted prior to clearance of this deficiency and departure.
74 SOLAS (20) IX/3.1 ISM CODE PART A/10.1
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 9 March 2024
Resolved
Every life raft shall be stowed with its painter permanently attached to the ship. PSCOs observed all four life rafts stowed with the painters improperly attached to the ship. The painters were secured to the anchor point with a hitch clove knot verses following manufacturer’s instructions of using a shackle.
74 SOLAS (20) III/13.4.1
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 9 March 2024
Resolved
Rescue boats shall be stowed: in a position suitable for launching and recovery. PSCOs observed the rescue boat quick release hook improperly attached to the rescue boat lifting bridle, crimping and damaging the wire rope.
74 SOLAS (20) III/14.2
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 9 March 2024
Resolved
The arrangement of the bilge and ballast pumping system shall be such as to prevent the possibility of water passing from the sea and from water ballast spaces into the cargo and machinery spaces, or from one compartment to another. PSCOs observed a 2” hole on the starboard side ballast air vent.
74 SOLAS (20) II-1/21.1.4
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 9 March 2024
Resolved
The means for securing these doors weathertight shall consist of gaskets and clamping devices or other equivalent means and shall be permanently attached to the bulkhead or to the doors themselves...
PSCOs observed weathertight doors leading into aft compartments located above the port and starboard engine rooms with missing gaskets.
ICLL 66 ANNEX 1/ REG 1
07 - Fire Safety › N/A - No Subsystem › Emergency Escape Breathing Device and disposition
Issued 9 March 2024
Resolved
On all ships, within the machinery spaces, emergency escape devices shall be situated ready for use at easily visible spaces, which can be reached quickly and easily at any time in the event of fire...
74 SOLAS (20) II-2/Reg 13.4.3.1
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 9 March 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCOs observed the only bilge alarm in the machinery space to be inoperable.
74 SOLAS (04) I/11
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 9 March 2024
Resolved
Not less than 12 rocket parachute flares, complying with the requirements of section 3.1 of the Code, shall be carried and be stowed on or near the navigation bridge.
PSCOs observed 0 parachute flares on the navigation bridge, vessel was carrying all hand flares
74 SOLAS (20) III/6.3
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 9 March 2024
Resolved
A fixed fire detection and fire alarm system shall be provided in accordance with the provisions of this regulation. PSCOs observed 2 out of 3 smoke detectors tests in the Engine room failed to alarm.
74 SOLAS (20) II-2/7.2.2.1
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 March 2024
Resolved
Electrical installations shall be such that: the safety of ... crew and ship from electrical hazards will be ensured. PSCOs observed exposed electrical wiring associated with both the port and starboard control steering modules.
74 SOLAS (04) II-1/40.1.3
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 9 March 2024
Resolved
A line-throwing appliance complying with the requirements of section 7.1 of the Code shall be provided. Every line-throwing appliance shall include not less than four projectiles. PSCOs observed only three line-throwing appliances. Vessel is missing one line-throwing appliance.
74 SOLAS (20) III/18 LSA CODE 7.1
10 - Safety of Navigation › N/A - No Subsystem › Rate-of-turn indicator
Issued 9 March 2024
Resolved
The following maneuvering information prominently displayed on a fact sheet in the wheelhouse:
At the bottom of the fact sheet, the following statement: “warning”
The response of the (name of the vessel) may be different from that listed above if any of the following conditions, upon which the maneuvering information is based, are varied: (1) Calm weather—wind 10 knots or less, calm sea; (2) No current; (3) Water depth twice the vessel's draft or greater; (4) Clean hull; and (5) Intermediate drafts or unusual trim. PSCOs observed the lack of the proper warning label located on the maneuvering fact sheet posted in the wheelhouse.
33 CFR 164.35(g)(7)
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 9 March 2024
Resolved
A ship, except a ship of less than 26 feet in length, must have a placard of at least 5 x 8 inches, made of durable material fixed in a conspicuous place in each machinery space, or at the bilge and ballast pump control station, stating the following: Discharge of Oil Prohibited……. PSCOs observed Discharge of oil prohibited placard missing in the machinery space.
33 CFR 155.450
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 March 2024
Resolved
Electrical installations shall be such that: the safety of the passengers, crew and ship from electrical hazards will be ensured.
PSCOs observed exposed wires in the machinery space control switchboard.
74 SOLAS (04) II-1/40.1.3
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 9 March 2024
Resolved
The angular position of the rudder shall: be recognizable in the steering gear compartment. PSCOs observed engine steering gear room did not have a rudder angle indicator.
74 SOLAS (04) II-1/29.11.2
10 - Safety of Navigation › N/A - No Subsystem › Signalling lamp
Issued 9 March 2024
Resolved
All ships 150 gross tonnage and upwards ... shall ... be fitted with a daylight signaling lamp using an energy source of electrical power not solely dependent upon the ships power supply. Ship was not supplied with a daylight signaling lamp complying with the regulations.
PSCOs observed the lack of an alternative energy source for the daylight signaling lamp.
74 SOLAS (20) V/19.2.2.2
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 August 2023
Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. Fixed CO2 for engine room can only be operated mnaually/locally.
74 SOLAS (04) II-2/14.1.1
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 29 July 2022
Resolved
Emergency source of power is a generator it shall be started automatically. The E-Gen is not fit to start automatically upon failure of the main source of electrical power and does not have a secondary means of starting. 74SOLAS(2004) II-1/43.3.1
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 29 July 2022
Resolved
The angular position of the rudder shall be recognized in the steering gear compartment. The port side rudder indicator in the steering compartment is missing. 74SOLAS(2004) II-1/29.11
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 7 January 2021
Resolved
Rescue boats must be stowed in a continuous state of readiness for launching... rescue boat did not have adequate fuel for starting.
74 SOLAS (04)
III/4.1
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 January 2021
Resolved
Lifebuoys shall be stowed as to be capable of being rapidly cast loose, and not permanently secured in any way.
74 SOLAS (04)
III/7.1.1.2
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 28 June 2018
Resolved
01-0740 74 SOLAS(14)CHAP II-2 REG. 10.2.2.2 Ships shall be provided with independently driven fire pumps. In cargo ships of 1,000 or more GT at least 02 shall be provided. A coupling broke on the emergency fire pump rendering it inoperable.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 28 June 2018
Resolved
02-0715 74 SOLAS (14) II-2 REG. 7.2.1 A fixed detection system shall be provided. Fire detector above Port Main Engine would not alarm during test.
Operations/Management › Drills/Instruction › Not Conducted
Issued 2 November 2017
Resolved
0925-Vessel could not provide proof that Enclosed Space drills were being completed. 74SOLAS(14) III/19.3.3 - 40ac
Fire Fighting › Fixed Fire Detection System › Manually Operated Call Points
Issued 2 November 2017
Resolved
1020 - Manually operated call points shall be placed effectively to ensure a readily accessible means of notification. Two (2) call points on main deck exterior only give a fault on the bridge panel when activated. 74SOLAS(2014) II-2/7.1.2 40ac
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 2 November 2017
Resolved
1030 - A low level alarm for each hydraulic fluid reservoir for each hydraulic power operated steering gear audible and visual alarms shall be given on the navigational bridge. Alarm on bridge is continually activated. 74 Solas(2014) II-1/29.12.2 40ac
Engineering › Steering Gear System › Piping
Issued 2 November 2017
Resolved
1499 - Each hydraulic power operated steering gear shall be provided with a fixed storage tank having a capacity to recharge at least one power actuating system. Crew utilizes buckets transported from the engine room to refill. 74 SOLAS (2014) II-1/29.12.3 40ac
Fire Fighting › Fire Hoses › Location
Issued 2 November 2017
Resolved
0720 - Ships shall be provided with fire hoses, the number and diameter of which shall be to the satisfaction of the administration. Two fire hose stations on port side were unable to be used due to location of cargo. 74 SOLAS (2014) II-2/10.2.3.2.1 10c
Construction/Loadline › Structures › Machinery Space Opening
Issued 2 November 2017
Resolved
9800 - Two means of escape shall be provided from each machinery space. Emergency escape from engine room was blocked by benches. 74 SOLAS (2014)II-2/13.4.2.1 10c
Pollution Prevention/Response › Prevention Equipment › Standard Discharge Connection
Issued 2 November 2017
Resolved
1735 - Ships discharge pipeline for sludge residues shall be fitted with a standard discharge connection. Vessel IOPP Form A states vessel has a standard discharge connection, crew could not prove location. 74/78 MARPOL (2011) I/13 40ac
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 12 January 2017
Resolved
1720 OIL FILTERING EQUIPTMENT SHALL BE PROVIDED WITH AN ALARM AND AN ARRANGEMENT TO ENSURE THAT ONLY WATER MIXTURE DISCHARGE IS AUTOMATICALLY STOPPED WHEN OIL CONTENT OF THE EFFLUENT EXCEEDS 15 PPM. PSC OFFICER REQUESTED TEST OF ALARM AND ARRANGEMENT TO STOP DISCHARGE OF OILY WATER MIXTURE EXCEEDING 15 PPM. CREW COULD NOT PROVIDE 15 PPM ALARM OR STOP DISCHARGE OF 15 PPM OILY WATER MIXTURE. 40A
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 12 January 2017
Resolved
0710 PAINT LOCKERS SHALL BE PROTECTED BY A FIRE EXTINGUISHING ARRANGEMENT APPROVED BY THE ADMINISTRATION. PSC OFFICER OBSERVED PAINT BEING STORED IN A CARGO CONTAINER WITHOUT A FIXED FIRE FIGHTING SYSTEM. 74 SOLAS CONS 2104 CHAP II-2 REG10 6.3.2 40Ac
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 12 January 2017
Resolved
2035 FIRE CONTROL PLANS AND BOOKLETS SHALL BE KEPT UP TO DATE. PSC OFFICER NOTICED THE FIRE CONTROL PLAN REFLECTED THE VESSEL'S PREVIOUS NAME AND THE MUSTER LIST HAD NOT BEEN UPDATED SINCE 2015. 74 SOLAS CHAP II-2 REG 15 2.4.1 40Ac
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.