Records from 2016 to 2022. Most recent: inspection, 5 October 2022.
Inspection history · 14
5 October 2022
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7572390
18 July 2022
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7510312
28 January 2022
Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7386913
1 July 2021
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7241351
26 May 2021
Administrative Inspection · Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7207758
17 February 2021
Plan Review "T" Boat · Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7152679
10 June 2020
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6973369
21 January 2020
Drydock Exam · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6892592
30 September 2019
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6824291
27 February 2019
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6634991
13 February 2019
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6625377
31 January 2018
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6343603
10 March 2017
Administrative Inspection · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6098565
3 October 2016
Construction Oversight · COI Inspection · Plan Review "T" Boat · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6064996
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 July 2022
Resolved
On a vesse of at least 65 ft in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. The bilge high level alarms doesn't have an audible alarm.
46 CFR 182.530(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2022
Resolved 5 August 2022
Resolution: Vessel representative send video of corrected deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 6 August 2021
Resolved
Vapor Barriers. Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces. Vessel's bulkhead from engine space to main void lacking vapor tight integrity on port and starboard cable runs. Provide adequate vapor tight cable runs to bulkhead.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2022
Resolved 15 August 2022
Resolution: Vessel sent in photos of vapor tight insulation. Cleared deficiency.