Records from 2016 to 2026. Most recent: inspection, 19 May 2026.
Documentation record
Registered dimensions (L × B × D)80.4 ft × 26.3 ft × 9.2 ft
Registered tonnagegross 90 / net 61
ITC dimensions (L × B × D)80.4 ft × 26.3 ft × 9.2 ft
ITC tonnagegross 162 / net 59
BuilderHORIZON SHIPBUILDING · BAYOU LA BATRE, AL, UNITED STATES · built 2017
Hull materialAluminum
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 4 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it162 - Convention (Subpart B), Gross Ton
90 - Regulatory (Subpart C or D), Gross Ton
59 - Convention (Subpart B), Net Ton
61 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 32
19 May 2026
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8376084
24 April 2026
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8355324
20 May 2025
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8139287
4 October 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8014272
21 May 2024
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7915925
19 April 2024
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7898059
12 December 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7838307
15 September 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7792179
29 August 2023
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7780403
23 May 2023
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7695003
28 April 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7677111
31 May 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7463866
18 May 2022
Internal Structural Exam · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7453647
8 June 2021
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7219166
15 August 2020
Damage Survey · Deficiency Check · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7034080
11 June 2020
Drydock Exam · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6974185
9 June 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6972158
20 September 2019
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6816465
5 September 2019
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6804425
15 May 2019
Annual Inspection · DAPI Audit
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6684563
13 December 2018
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6597282
8 November 2018
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6577271
13 June 2018
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6448302
10 June 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6441428
10 June 2018
Administrative Inspection · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6442187
16 May 2018
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6415659
9 April 2018
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6387948
30 December 2017
In-Service Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6331189
2 August 2017
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6260242
28 July 2017
Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6223635
28 July 2017
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6223907
3 November 2016
Plan Review "T" Boat · Hull Examination · Construction Oversight · Administrative Inspection · Internal Structural Exam · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6076498
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 May 2023
Resolved
The following spaces must be equiped with a fixed fire fighting system; A space containing propulsion machinery.
Vsl must demonstrate proper operation of the fixed firefighting system in the presence of a Marine Inspector. system was not operational during inspection and port engineers were troubleshooting.
46 CFR 181.400(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2023
Resolution: Conducted a satisfactory test of the vessel's fixed firefighting system. MI witnessed satisfactory test of automatic engine shutdown & resets (override function test).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 April 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations
Prior to carrying passengers, provide a causal-analysis report identifying the contributing factors that led to the loss of propulsion in the engine, as well as a report from an attending technician certifying that any necessary repairs have been satisfactorily completed, and conduct sea trials with a qualified marine inspector
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 August 2020
Resolved
Vessel Captain reported experiencing a loss of propulsion that reduced the maneuverability of the vessel. CG-835V to be cleared upon submission of causal analysis and tech report and satisfactory completion of an underway sea trial.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2020
Resolution: Attending marine inspector verified satisfactory repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 September 2019
Resolved
vessel reported a loss of forward/reverse shifting on Port main engine and "low oil pressure" alarm. Vessel removed from service and engineers are investigating the source of issue.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2019
Construction/Loadline › Structures › Transverse Bulkhead
Issued 16 May 2018
Resolved
vessel is to provide a repair proposal for crack in the forward engine room bulkhead and conduct permanent repairs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2018
Resolved 31 May 2018
Resolution: vessel provided documentation of permanent repairs.
Navigation › Piloting/Steering › Marine Charts
Issued 16 May 2018
Resolved
provide up to date charts
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2018
Resolved 16 May 2018
Resolution: vessel provided up to date charts
Documentation › Certificates/Documents › Certificate of Inspection
Issued 16 May 2018
Resolved
vessel was unable to provide original COI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 31 May 2018
Engineering › Bilge Water Management System › Piping
Issued 30 December 2017
Resolved
Vessel has un-authorized nonmetallic piping in a vital system. Vessel must remove plastic piping and repair back to original material previously approved by MSC. 46CFR176.700/182.710
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 December 2017
Resolution: Vessel replaced piping back to original material previously approved by MSC.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 30 December 2017
Resolved
Vessel must remove the line holding the loading door and rail in place and make proper repairs to the latching system. 46CFR176.830
Due 12 January 2018
Resolved 30 December 2017
Resolution: Vessel removed line and fixed latches.
Construction/Loadline › Hull › Stiffener
Issued 5 September 2017
Resolved
Repair cracked weld in from in port engine room. Adjecent to reduction gear, inboard side.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 10 September 2017
Resolved 6 September 2017
Resolution: Received photo from operator of re-welded seam in the E/R.
Construction/Loadline › Hull › Stiffener
Issued 5 September 2017
Resolved
Repair flange on main tranverse frame, near the inboard chine, adjecent to the generator in the starboard engine room.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 10 September 2017
Resolved 6 September 2017
Resolution: Received photo from operator of re-welded seam in the E/R.
Engineering › Freshwater System (cylinder head cooling) › Hose
Issued 5 September 2017
Resolved
Provide double hose clamps for jacket water heaters on port and starboard main engines.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 10 September 2017
Resolved 6 September 2017
Resolution: Received photo from operator of hoses with double hose clamps.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 July 2017
Resolved
Conduct new to zone inspection prior to operating to determine zone specific operational constraints and route limitations.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 August 2017
Resolved 2 August 2017
Resolution: Conducted new to zone inspection on 02AUG2017.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 14 July 2017
Resolved
Prove proper operation of the installed Magna Lock system to include when power failure occurs, the system is de-energized, allowing all doors to open.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 July 2017
Resolved 15 May 2019
Resolution: MAGNA LOCKS WERE REMOVED FROM ALL DOORS. DEFICIENCY CLEARED. -[name withheld]