MIGUEL KEITH

MIGUEL KEITH is a 2019 public vessel, unclassified. The Coast Guard has recorded 41 inspections since 2016, most recently in June 2026, along with 39 deficiencies and 3 operational controls.

Records from 2016 to 2026. Most recent: inspection, 1 June 2026.

Built
2019
Last inspected
1 June 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9822803
1425956
Flag
UNITED STATES
Maury page id
psix-1425956

Inspections, by type

…with no type recorded5
Years with a record 9 calendar years (2016–2026)
The 41 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it20063 - Convention (Subpart B), Net Ton
71954 - Dead Weight, Ton
37023 - Displacement, Ton
66878 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 41

1 June 2026 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8385122
5 January 2026 Vessel Attendance · ACP Annual Oversight · Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 8289931
17 April 2025 ACP COI Oversight · COI Inspection · Re-Inspection · Administrative Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 8103001
14 August 2024 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7981503
17 July 2024 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7963894
28 February 2024 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7886158
5 December 2023 Administrative Inspection · Annual Inspection · ACP Annual Oversight
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7833608
11 October 2023 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7806455
29 November 2022 ACP Annual Oversight · Annual Inspection · Administrative Inspection · Underwater Inspection in lieu of Drydock
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7601623
10 July 2022 Deficiency Check · ACP Additional Oversight – Risk Assessment
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7502851
10 June 2022 Construction Oversight
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7530965
14 February 2022 Administrative Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7412634
22 November 2021 ACP Annual Oversight · Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7355361
8 October 2021 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7329264
23 August 2021 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7285071
23 August 2021 ACP Additional Oversight – Risk Assessment
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7294225
6 May 2021 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7221549
29 March 2021 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7166200
17 March 2021 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7159301
18 February 2021 Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7142246
10 February 2021 Excursion Permit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7138936
4 February 2021 Annual Inspection · Deficiency Check · ACP Annual Oversight
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7135493
23 November 2020 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7100823
30 September 2020 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7068586
8 June 2020 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 6971537
3 April 2020 Excursion Permit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6935204
3 March 2020 Excursion Permit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6920010
27 February 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6916798
25 February 2020 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6917752
11 February 2020 Excursion Permit · Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6908121
10 February 2020 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6920541
30 January 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6899347
28 January 2020 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6898805
21 January 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6893511
29 December 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6880260
13 December 2019 Excursion Permit · Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6873651
11 September 2019 Load Line/Change of Employment · Examination of Repairs
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6826445
2 August 2019 Ballast Water Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6770703
23 July 2019 Load Line/Change of Employment
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6759255
17 July 2019 Administrative Inspection · ACP Handover Survey · Deficiency Check · Construction Oversight · COI Inspection · Initial Certification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6775887
17 November 2016 Plan Review (Other than "T") · Administrative Inspection · Construction Oversight
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6189971

Deficiency record · 39

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 January 2026 Resolved
Main and auxiliary machinery essential for the propulsion and safety of the ship shall be provided with effective means for its operation and control. The attending marine inspector was unable to ascertain if all the required automation testing approved by ABS has been completed as the documentation is in complete. Some of the PSTP testing was conducted by the OEM however not tracked or logged withing the shipboard systems. Provide evidence that all approved and required ABS PSTP testing was complete in 2025 and on track to be completed in 2026. SOLAS II-1/31
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2026
Resolved 10 March 2026
Resolution: Recieved documentation from the vessel showing completion of all onboard PSTP's with an ABS approval having witnessed them.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 5 January 2026 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The attending MI noted that both lifeboats tiller arm was connected in a non standard way and that a cotter pin was holding the steering together. Restore to OEM standards for lifeboat steering.SOLAS III/20.2
Action required: 10 - Deficiency Rectified
Due 15 January 2026
Resolved 15 January 2026
Resolution: Corrected during the MI's attendance.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 January 2026 Resolved
A minimum of two two way portable radio's shall be suppled for each fire party for firefighters communication. Those two way radios shall be explosion proof or intrinsically safe. It was noted during the fire drill that the fire teams didn't utilize radios for communication. Further investigation revealed that there were no fire fighters available to the fire teams and the designated radios were being used elsewhere on the ship. SOLAS II-2/10.10.4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2026
Resolved 15 February 2026
Resolution: Radios have been designated and assigned to the fire locker and images to collaborate this have been received.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 5 January 2026 Resolved
Firefighters outfits shall comply with the Fire Safety Systems Code: Fire Fighters outfit shall consist of a set of personal equipment and a breathing apparatus. Attending marine inspector noted that the fire fighters outfits were missing the Axe with handle provided with high voltage insulation (small hatchet) required by FSS chapter 3. Two of these hatchets is required per damage control locker. These are typically worn on the fireman outfit with belt and holster.SOLAS II-2/10.10.1 FSS. 3.2.5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2026
Resolved 15 February 2026
Resolution: Received confirmation of replacement order for axes to add to the fire lockers.
09 - Working and Living Conditions › 092 - Working Conditions › Danger areas
Issued 5 January 2026 Resolved
Hospital Spaces: The room and equipment must be available for immediate use. Attending MI noted that the toilet is marked do not use, water pressure to the sink in the space is reduced and brown on initial turn on. Items are being stowed in the bathroom and the medical supply bag containing medications with an expiration date expired in October of 2025, items inside the bag were also verified and confirmed expired in many cases.46CFR92.20-35
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2026
Resolved 8 April 2026
Resolution: Received confirmation that expired medicaion has been ordered and recieved.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 16 December 2023 Resolved
Nautical charts necessary for intended voyages shall be kept up to date. ECDIS license for electronic charts expired as of 30Nov2023 - ship has satisfactory paper charts for voyage to Guam - rectify ECDIS chart upgrades by next port.
Action required: 15 - Rectify deficiencies by next port
Resolved 28 March 2024
Resolution: MSC contract renewed and valid till Sep2024
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 16 December 2023 Resolved
Equipment shall be maintained onboard for safety to proceed to sea. Bridge dynamic positioning panel was found inop. Repairs due to restore panel function or replace at next maintenance period.
Action required: 705 - Other - as specified
Resolved 28 March 2024
Resolution: ABS verified new panel install and tested
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 December 2023 Resolved
The fire resistance rating of fire doors shall be equivalent to the level of the division in which they are fitted. MI noted fwd house fire door boundary was not equivalent to division - (A4 deck galley area - A4-91-13 stbd) - fire door needs to be replaced with properly rated fire door for division.
Action required: 705 - Other - as specified
Resolved 16 January 2024
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 16 December 2023 Resolved
The general alarm and public address system shall be audible throughout all accommodations and normal crew working spaces. Noted concerns with 1MC and GA amplifier UPS electrical configuration. During testing, UPS batteries were found depleted and system not covering mission deck/fwd house. Further investigation required w/in 30 days to determine system automatic/manual changeover procedures for emergency power.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 January 2024
Resolved 22 December 2023
Resolution: Verified w/ OEM and ABS, tested sat
08 - Alarms › N/A - No Subsystem › General alarm
Issued 12 July 2022 Resolved
The general alarm shall be audible throughout all the accommodation and normal crew working spaces. Prove operation of general alarms Repair and prove operation of the following General Alarms ( 1MC): 1) Exterior forward of house along multiple stair flats. 2) Fan RM/ELECT EQPT (A3-95-3) space 3) SUPPORT SERV (A1-92-2) space
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2022
Resolved 10 August 2022
Resolution: See ABS' Vessel Status Report (For Owner) dtd 10AUG2022 uploaded to Documents.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 July 2022 Resolved
The fire resistance of doors shall be equivalent to that of the division in which they are fitted, this being determined in accordance with the Fire Test Procedures Code. Repair and prove proper operation of the following Fire Rated and A/C Boundary doors: 1) A1-90-2 (A-0 door must self-close) 2) A2-91-9 (bottom hose port stays in open position when door is closed) 3) A1-93-2 (A-0 door – repair all around gasket) 4) A-53-1 (B-15 door – unable to properly close along head jamb)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2022
Resolved 10 August 2022
Resolution: See ABS' Vessel Status Report (For Owner) dtd 10AUG2022 uploaded to Documents.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 July 2022 Resolved
All emergency lights shall be marked with a letter “E” at least 1/2 inch high and emergency lighting at the following locations described in SOLAS Chapter II-1, Regulation 43/2.1 and 2.2: every muster and embarkation station and over the sides, all service and accommodation alleyways, stairways, etc. Verify/label “E” lights in forward house, port and starboard stairways.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2022
Resolved 10 August 2022
Resolution: See ABS' Vessel Status Report (For Owner) dtd 10AUG2022 uploaded to Documents.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 12 July 2022 Resolved
Containers, brackets, racks, and other similar stowage locations for lifesaving equipment shall be marked with symbols in accordance with the recommendations of the Organization, indicating the devices stowed in that location for that purpose. Replace 25 x person placards on port and starboard with correct placard for 10 x person life rafts located on forward end of bow as per vessel's approved safety control plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2022
Resolved 10 August 2022
Resolution: See ABS' Vessel Status Report (For Owner) dtd 10AUG2022 uploaded to Documents.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 July 2022 Resolved
Containers, brackets, racks, and other similar stowage locations for lifesaving equipment shall be marked with symbols in accordance with the recommendations of the Organization, indicating the devices stowed in that location for that purpose. Replace Lifeboat placards on port and starboard doors posted on A4 and A5 levels in forward house with Life Raft placards with arrows indicating location of life rafts on Mission deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2022
Resolved 10 August 2022
Resolution: See ABS' Vessel Status Report (For Owner) dtd 10AUG2022 uploaded to Documents.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 July 2022 Resolved
Each lifebuoy shall be marked in block capitals of the Roman alphabet with the name and port of registry of the ship on which it is carried. Remark vessel’s name on port side ring buoy. Name has faded due to sun/weather exposure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2022
Resolved 10 August 2022
Resolution: See ABS' Vessel Status Report (For Owner) dtd 10AUG2022 uploaded to Documents.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 12 July 2022 Resolved
The main steering gear and rudder stock shall be capable of putting the rudder over 35 to 35 degrees on the other side…Observed by attending MI that during steering test (35 to 35), rudder angle indicator is off by +/- 2 degrees when tested to port and starboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2022
Resolved 10 August 2022
Resolution: See ABS' Vessel Status Report (For Owner) dtd 10AUG2022 uploaded to Documents.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 July 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. A portion of the port steering gear space has been outfitted to serve as an unapproved welding shop according to MSC’s SMS Procedures Manual.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2022
Resolved 10 August 2022
Resolution: See ABS' Vessel Status Report (For Owner) dtd 10AUG2022 uploaded to Documents.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 July 2022 Resolved
Electrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. Electrical protective equipment required by MSC’s SMS Procedures Manual were found to be expired and not being tested at mandatory intervals.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2022
Resolved 10 August 2022
Resolution: See ABS' Vessel Status Report (For Owner) dtd 10AUG2022 uploaded to Documents.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 July 2022 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Electrical power sources for equipment installed after construction as part of the vessels potable water system are not terminated in a suitable electrical junction box as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2022
Resolved 10 August 2022
Resolution: See ABS' Vessel Status Report (For Owner) dtd 10AUG2022 uploaded to Documents.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 12 July 2022 Resolved
Doors provided to ensure the watertight integrity of internal openings which are used while at sea are to be sliding watertight doors capable of being remotely closed from the bridge and are also to be operable locally from each side of the bulkhead. Holdbacks were found throughout the engine rooms sliding watertight doors disabling the ability to remotely close the doors from the bridge or engine control room as required.
Action required: 10 - Deficiency Rectified
Resolved 12 July 2022
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 12 July 2022 Resolved
To assist in casualty investigations, ships, when engaged on international voyages, subject to the provisions of regulation1.4, shall be fitted with a voyage data recorder (VDR). Corrected Prove operation of VDR prior to vessel’s departure (LCD screen reads “not recording” with non-float free error).
Action required: 10 - Deficiency Rectified
Resolved 15 July 2022
Resolution: Verified error cleared and VDR operating with no errors/fault showing.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 12 July 2022 Resolved
In the event of a failure of electrical power supply to the control system, an audible and visual alarms shall be given on the navigation bridge…Corrected Prove operation of audible alarm for loss of power/steering failure. Audible and visual alarm required for steering failure.
Action required: 10 - Deficiency Rectified
Resolved 15 July 2022
Resolution: Witnessed test of audible and visual alarms for steering failure on bridge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 December 2021 Resolved
Measures shall be taken to ensure the equipment is functioning in a reliable manner and regular inspections and routine tests are made to ensure continuous reliable operation. Upon completion of operational load testing of the Emergency Diesel Generator (EDG), the main electrical supply was unable to be immediately restored, with the dark ship condition persisting for 90+ minutes before main power was restored. 74 SOLAS (2020) II-2/46 74 SOLAS (2020) II-2/41.5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 January 2022
Resolution: ABS witnessed satisfactory testing of the power distribution system.
11 - Life Saving Appliances › N/A - No Subsystem › Emergency equipment for 2-way comm.
Issued 23 August 2021 Resolved
01 of 03 lifeboat VHF radios found inoperable. Provide 01 operational lifeboat radio. Ensure all lifeboat radio spare batteries are operational. SOLAS 74am (14 ConsEd) Chap III/6.2.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 August 2021
Resolution: Received preliminary report from work order #4750065. ABS verified radio was improperly placed on charger. Crew trained.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 August 2021 Resolved
Vessels fire main charging pump was found to be holed and leaking water from the discharge side of the piping. Make class approved repairs and prove proper operation. SOLAS 74am (14 ConsEd) Chap II-2/10.2.2.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 August 2021
Resolution: Received preliminary report from work order #4750065. Temp repair made and tested to 115% operating pressure. Final repairs to be completed by 03DEC2021.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 23 August 2021 Resolved
Required fireman's equipment radios (x2) not on station. Include 02 radios on DC locker equipment checklist (SMS) and keep stored on charging station provided for radios in locker for use in emergencies. SOLAS 74am (14 ConsEd) Chap II-2/10.10.4
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2021
Resolved 31 August 2021
Resolution: Received preliminary report from work order #4750065. Radios found in DC Locker and on DC Locker inventory.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for rating for watchkeeping
Issued 23 August 2021 Resolved
01 crewmember did not have original MMC on board (Deck Machinist). Provide original MMC onboard. 46CFR 10.233(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2021
Resolved 26 August 2021
Resolution: Crewmember had his MMC mailed to the ship. Master has physically laid eyes on the MMC and sent statement via e-mail.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 23 August 2021 Resolved
Aft galley remote and local fire damper indicators panel failed to show accurate damper position. Forward galley on screen display did not show accurate position of dampers. SOLAS 74am (14 ConsEd) Chap II-2/9.7.1.2.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2021
Resolved 31 August 2021
Resolution: Received preliminary report from work order #4750065, accepted as Statutory Condition.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 23 August 2021 Resolved
During raising of starboard lifeboat polyamide sheaves with life-time lubricated bushings were found with audible indications of possible bushing failure which may require further maintenance. Manufacturer authorized rep shall make additional inspection of sheaves and provide report. SOLAS 74am (14 ConsEd) Chap 1/11
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2021
Resolved 31 August 2021
Resolution: Received preliminary report from work order #4750065. Requesting 90-day extension.
14 - Pollution Prevention › 145 - MARPOL Annex V › Other (MARPOL Annex V)
Issued 23 August 2021 Resolved
Garbage record book was missing entries for food waste and incineration at see from 14JUL21 to 21JUL21. Update garbage record book from deck log entries and provide training to crew. MARPOL 73/78(17 ConsEd) Annex I/10.3.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2021
Resolved 31 August 2021
Resolution: Received preliminary report from work order #4750065. Garbage Record Book updated.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 23 August 2021 Resolved
On deck life boat remote release mechanism wire was not long enough to reach railing. Make repairs to reposition or lengthen wire for mechanism. SOLAS 74am (14 ConsEd) Chap III/16.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2021
Resolved 31 August 2021
Resolution: Received preliminary report from work order #4750065. Wire was replaced with sufficient length to reach deck rail.
11 - Life Saving Appliances › N/A - No Subsystem › Evaluation, testing and approval
Issued 23 August 2021 Resolved
Lifeboat additional seating added (2nd level) found to not conform to LSA code seating arrangements. Upper seating does not have footrests and positions of upper to lower overlap (feet/legs in faces). 02 lower seats (just forward of helm) found with interferences in way of seating arrangements. Provide USCG approved drawings for seating arrangements. SOLAS 74am (14 ConsEd) Chap III/31.1.1.1 & LSA Code 4.4.2.2.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2021
Resolved 1 September 2022
Resolution: Rcvd USCG approved drawings for lifeboat seating modifications uploaded to Documents.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 23 August 2021 Resolved
Buoyant smoke signals for lifeboats found expired. Spare buoyant smoke found on board. SOLAS 74am (14 ConsEd) Chap III/34 & LSA Code 4.4.8.15
Action required: 10 - Deficiency Rectified
Resolved 23 August 2021
Resolution: 04 non-expired buoyant smoke found in ship spares and placed in lifeboats.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 31 March 2021 Resolved
Vessel's 3 GHz S-band radar is non-functional. Repair/replace the S-band radar.
Action required: 705 - Other - as specified
Resolved 31 March 2021
Resolution: Vessel was issued an inbound LOD. Class has accepted as a condition of class.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 February 2021 Resolved
Materials readily rendered ineffective by heat shall not be used in fire mains. A temporary FRP patch was installed on the fire main in the pump room cord piping. Provide repair plan for pinhole leak in pump room cord fire main to the satisfaction of Class. Due 18March2021. 74SOLAS(14) II-2/10.2.1.1.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 March 2021
Resolution: Deficiency accepted as outstanding condition.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 February 2021 Resolved
Suitable instructions and component spares for testing and maintenance of fire detection system shall be provided to the vessel. No approved testing components for flame detectors are on board. Provide testing components IAW USCG approved manual.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2021
Resolved 26 February 2021
Resolution: New Consilium Salwzco IR Test Lamp for flame detectors procured and tested by attending ABS Surveyor.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 21 January 2020 Resolved
Vessel's X-Band Radar is not operating as intended. Make proper repairs and provide technician report indicating cause of failure, repairs completed and specific testing conducted to demonstrate unit is returned to proper operating condition. 33 CFR 164.37
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2020
Resolution: Tech Report provided indicating adequate repair and testing.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 21 November 2019 Resolved
Before the ship leave port and at all times during the voyage, all life-saving appliances shall be in working order. Remove paint on welds at stbd lifeboat davit braces for further inspection as identified by Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2019
Resolution: Mag particle testing completed all SAT.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Certification, verification and control
Issued 21 November 2019 Resolved
A Safety Management Certificate shall be issued to every ship. Obtain a valid Safety Management Certificate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2020
Resolution: Witnessed initial ISM Audit. Interim Certificate issued.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.