HAFNIA KIRSTEN

HAFNIA KIRSTEN is a 2017 tank ship. The Coast Guard has recorded 20 inspections since 2017, most recently in March 2026, along with 14 deficiencies and 8 operational controls.

Records from 2017 to 2026. Most recent: inspection, 29 March 2026.

Built
2017
Last inspected
29 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9732682
9HA4203
1426241
Flag
MALTA
Maury page id
psix-1426241

Inspections, by type

…with no type recorded6
Years with a record 8 calendar years (2017–2026)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it14440 - Convention (Subpart B), Net Ton
49999 - Dead Weight, Metric Ton
61064 - Displacement, Metric Ton
29658 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 20

29 March 2026 PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8333581
4 March 2026 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8319633
7 January 2026 PSC B · Deficiency Check · COC-CHEM & TVE Renew · Appeal · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8290747
10 December 2025 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8281427
3 February 2025 COC-CHEM Annual
Type not classified · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8072373
11 January 2024 COC-CHEM & TVE Renew · PSC B
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7847165
10 January 2024 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7845531
12 November 2021 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7354501
15 June 2021 Deficiency Check · PSC B · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7220798
9 June 2021 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7220487
29 August 2020 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7045219
13 August 2020 Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7031984
12 August 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7031311
5 August 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7024574
15 October 2019 COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6825337
10 May 2019 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6681460
27 February 2019 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6634500
6 September 2018 ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6534282
20 February 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6358079
9 September 2017 Ballast Water Examination · COC-CHEM Renew · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6253977

Deficiency record · 14

07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 8 January 2026 Resolved
Fire protection systems and firefighting systems and appliances shall be maintained ready for use. PSCO observed rubber on half of the CO2 hoses in the CO2 room that were deteriorated. Maintenance records show that the hoses are over ten years old and were recommended for replacement back in 12DEC2025. 74 SOLAS (2020) II-2 / 14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 January 2026
Resolution: Received survey statement from DNV attesting to repairs/replacement.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 7 January 2026 Resolved
The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company. The technical and/or operational nature of deficiencies 02, 03, 04, 06, and 07 provide objective evidence of a serious failure, or lack of effectiveness, of the implementation of the ISM Code. A safety management audit carried out by the Administration or the RO, with a corresponding report of findings satisfactory to the OCMI must be submitted prior to clearance of this deficiency and release from detention. 74 SOLAS (2020) IX / 3.1 ISM Code 7
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 8 January 2026
Resolution: Received satisfactory external audit. Audit attached in documents.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 7 January 2026 Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed fuel oil leaking from the return line on top of the inert gas generator. PSCO observed oil traps and visible film from leaks down the side of the inert gas generator. 74 SOLAS (2020) II-2 / 4.1.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 8 January 2026
Resolution: Receieved class report attesting to completed repairs. PSCO observed repairs to the IGG were completed with no evidence of fuel oil leakage observed. The IGG was tested satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 7 January 2026 Resolved
Fire protection systems and firefighting systems and appliances shall be maintained ready for use. PSCO observed rubber on half of the CO2 hoses in CO2 room that were deteriorated. Maintenance records show that the hoses are over ten years old and were recommended for replacement back in 12DEC2025. 74 SOLAS (2020) II-2 / 14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 8 January 2026
Resolution: Vessel provided risk assessment(attached). Replacement hoses currently being shipped from the Netherlands to New York, with a tentative ETA of 12 JAN. Code 30 deficiency cleared. Issued new defiencey extending def by 14 days IAW PR-002(3).
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 7 January 2026 Resolved
Before ship leaves port and at all times during the voyage, all lifesaving appliance shall be in working order and ready for immediate use. PSCO observed outboard rescue boat motor unable to turn starboard. Steering ram linkage was connected improperly preventing full movement. SOLAS III/ 20.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 8 January 2026
Resolution: Received class report stating that the outboard rescue boat motor was now in working condition with full port and starboard movement.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 7 January 2026 Resolved
Oil tankers of 20,000 tonnes deadweight and above, constructed on or after 1Jan2012 shall be provided with a fixed hydrocarbon gas detection system complying with the fire safety systems code. PSCO unable to run satisfactory tests on the fixed gas detection system. 74 SOLAS (2020) II-2 / 4.5.7.3.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 January 2026
Resolution: Original code for this deficiency was a code 30. Deficiency was downgraded to a 17 after OCMI reconsideration. See attached letter.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 7 January 2026 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulation. PSCO observed temperature sensor 2P COT malfunctioning. 74 SOLAS (2020) I /11
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 January 2026
Resolution: Received survey statement from DNV attesting to repairs/replacement.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 January 2026 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulation. PSCO observed wasted conduit on the line for the temperature sensor flange of Cargo Pump 1P. 74 SOLAS (2020) I /11
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 January 2026
Resolution: Received survey statement from DNV attesting to repairs/replacement.
09 - Working and Living Conditions › 092 - Working Conditions › Stowage of cargo
Issued 3 February 2025 Resolved
A chemical tanker shall comply with requirements of the IBC...The stowage space shall be: Cell divided; made of material fully resistant to different liquids intended to be stowed. PSCO observed improper cargo sample stowage in sample locker to include stacked glass bottles outside of cell division and plastic pallets being used for flammable products.74SOLAS(20 Cons) VII/10.1, IBC 16.5.2
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2025
Resolved 10 February 2025
Resolution: Provided satisfactory class report and photographs attesting to rectification.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 3 February 2025 Resolved
A record shall be kept to the satisfaction of the administration and as required by radio regulations of all incidents connected with the radio communication service which appear to be of importance to the safety of life at sea. PSCO observed missing monthly entry for January 2025 in the GMDSS Log. 74SOLAS (20 Cons) IV/17.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 February 2025
Resolved 4 February 2025
Resolution: PSCO witnessed GMDSS equipment tested and properly logged.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 11 January 2024 Resolved
07108- Fire fighting systems shall be maintained and ready for use. The vessel could not demonstrate adequate pressure to the vessels fire fighting foam monitors on the cargo deck. 17ac/74SOLAS(20)II-2/14.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 January 2024
Resolved 12 January 2024
Resolution: Received satisfactory Class report. Monitors functional.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 15 June 2021 Resolved
Before the Ship Leaves Port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed mechanical linkage for the Rescue Boat engine shifter was broken.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 June 2021
Resolved 15 June 2021
Resolution: Vessel effected repairs to rescue boat linkage PSCO oberved rescue boat operating properly.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 June 2021 Resolved
Means shall be provided for Measuring the cargo temperature. PSCO observed temp sensors where inoperable. Vessel restricted from loading substances required to have means of measuring the cargo temperature by IBC Code, Chapt. 17, Column "J".
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 June 2021
Resolved 12 November 2021
Resolution: RO report provided attesting to the satisfactory repair of temp. sensors.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 15 June 2021 Resolved
Prevent the occurrence of fire and explosion. PSCO observed ventilation ducts in the oil purifier room had vents covered in dust and lint.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 June 2021
Resolved 15 June 2021
Resolution: Vessel effected cleaning of ventilation in purifier room.

Ownership record