MAURY USCG vessel records
← All vessels

KELLY LYNN II

Built
1976
Last inspected
11 August 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Fishing Vessel class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 August 2025
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2018–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH881
142659
Flag
UNITED STATES
Maury page id
psix-142659

Documentation record

Registered dimensions (L × B × D)36.0 ft × 13.3 ft × 6.5 ft
Registered tonnagegross 19 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA MARINE INDUSTRIES · SEATTLE, WA, UNITED STATES · built 1976
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBODEGA BAY, CA
Endorsements, as the file codes themfi, rec
DocumentationValid · issued 16 April 2026 · expires 30 April 2027
Service, as the file records itCommercial Fishing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it19 - Regulatory (Subpart C or D), Gross Ton
13 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 14 inspections, each with its date, unit and type; 36 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 14

11 August 2025 Type not recorded
No type recorded · Station San Francisco · USCG Southwest District (CGD-SW) · Activity 8208710
11 August 2025 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8209430
10 June 2024 COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7918192
1 August 2023 Deficiency Check · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7758004
31 July 2023 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7763258
5 April 2023 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7662148
18 March 2022 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7407905
24 September 2021 Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 7322409
30 July 2021 Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 7272729
1 June 2021 Administrative Inspection
Administrative · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 7212467
30 November 2020 Deficiency Check
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 7103674
21 September 2020 Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 7062447
7 May 2019 COI Inspection · Drydock Exam · Simplified Stability Test · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 6679023
6 September 2018 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 6534361

Deficiency record · 36

11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 June 2024 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to have the vessel ready for inspection of lifesaving equipment and systems, including the inspection of each hydrostatic release unit...The vessel's hydrostatic release for the inflatable buoyant apparatus was incorrectly arranged, operator made correction on the spot. 46 CFR 176.808(a)(5)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2024
Resolved 10 June 2024
Resolution: Corrected on the spot. Fixed installation of HRU
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 June 2024 Resolved
All fiber reinforced plastic (FRP) vessels constructed with general purpose resins must be fitted with a smoke activated fire detection system of an approved type, installed in accordance with § 76.27 in subchapter H of this chapter, in accommodation spaces; service spaces; and isolated spaces that contain an ignition source. Vessel did not have a smoke detector installed in engine room. 46 CFR 177.410 (c)(3)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2024
Resolved 5 September 2024
Resolution: Conducted def check, all sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 June 2024 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Identified areas beneath exterior benches that were connected to engine room (ER) and allowed air to flow freely. Provide appropriate means of sealing ER space to the satisfaction of the MI. 46 CFR 176.830
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2024
Resolved 5 September 2024
Resolution: New sealings created and observed during def check, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 10 June 2024 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the inspection and operation of all weathertight closures above the weather deck and the provisions for drainage of sea water from the exposed decks. Hatches for lazarette and engine room did not prevent water intrusion. Conduct repairs to create watertight integrity of the two hatches to the Satisfaction of the MI. 46 CFR 176.802
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2024
Resolved 5 September 2024
Resolution: Gasket replaced, all sat.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 10 June 2024 Resolved
A pre-engineered fixed gas fire extinguishing system must: (2) Be capable of manual actuation from outside the space in addition to automatic actuation by a heat detector. Vessel’s fire boy system was found with the maintenance safety pin still install after servicing, causing the system to be unable to use its manual activation. Remove safety pin to the satisfaction of the Marine Inspector. 46 CFR 181.420(a)(2)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2024
Resolved 5 September 2024
Resolution: Safety pin removed, all sat.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 10 June 2024 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and(2) General description of the drill scenario and training topics. Vessel was unable to provide the general descriptions of the Abandon ship and man overboard drills as required. Fill out the drill conducted during the inspection to the satisfaction of the Marine Inspector. 46 CFR 185.520(f)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2024
Resolved 5 September 2024
Resolution: Observed drills logged during def check, all sat.
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 10 June 2024 Resolved
Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. The training entry shall include the following information. (1) Date of the training; and (2) General description of the training topics. Vessel has no records of crew training. Conduct training and properly document the training to the satisfaction of the Marine Inspector. 46 CFR 185.420(d)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2024
Resolved 5 September 2024
Resolution: Crew training was logged, all sat.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 10 June 2024 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Vessel did not have alcohol testing devices on board. Procure new alcohol testing devices. 46 CFR 4.06-15(a)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2024
Resolved 5 September 2024
Resolution: New testing strips were on board, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 10 June 2024 Resolved
The inspection and maintenance of the equipment listed in paragraph (a) of this section shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel was unable to provide their IBA servicing report. Supply Marine Inspector with proper servicing report. 46 CFR 185.702(d)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2024
Resolved 5 September 2024
Resolution: Owner provided servicing report to MI, all sat.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 10 June 2024 Resolved
The master or person in charge of a ship, including a drilling rig or platform, to which this section applies shall ensure that one or more placards meeting the requirements of this section are displayed in prominent locations and in sufficient numbers so that they can be read by the crew and passengers. These locations must be readily accessible to the intended reader and may include embarkation points, food service facilities, garbage handling spaces, living spaces, and common areas on deck. Vessel did not have a placard that met the regulations of this part on board. Vessel owner must procure a placard and install on the vessel to the satisfaction of the Marine Inspector. 33 CFR 151.59(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2024
Resolved 5 September 2024
Resolution: New placard created and observed during def check all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 June 2024 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel experienced knocking on port engine, leading to vessel being hauled out for repairs. Provide root cause and conduct repairs to the satisfaction of the Marine Inspector. 46 CFR 182.200 (a)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2024
Resolved 9 August 2024
Resolution: Port engine was pulled for repairs. MI attended the vessel for sea trials with no issues.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 June 2024 Resolved
Repairs or alterations to the hull, machinery, or equipment that effect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Vessel is conducting repairs to the main engine without notifying the OCMI. 46 CFR 176.700
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 17 July 2024
Resolved 17 July 2024
Resolution: Deficiency rectified on the phone. Spoke to operator who then reported the issue.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 June 2024 Resolved
If the annual inspection reveals deficiencies in your vessel's maintenance, you must make any and all repairs or improvements within the time period specified by the OCMI. Vessel was issued ten deficiencies on 10JUN2024 that were to be rectified within 14 days, without correcting any as of 17JUL2024. Vessel is to rectify all deficiencies, referenced on the 835V issued 10JUN2024, within 14 days of issuance of this new 835V. 46 CFR 176.500 (1)(iii)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2024
Resolved 5 September 2024
Resolution: Vessel currected pending defs, all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 June 2024 Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Vessel unable to provide required documentation for drug and alcohol program. Provide required documentation to satisfaction of MI within 7 days in order to complete USCG chemical testing program compliance audit. 46 CFR 185.100
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 September 2024
Resolved 27 September 2024
Resolution: Received docs for DAPI audit
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 June 2024 Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Vessel's drug and alcohol program is not in compliance with 46 CFR Parts 4 and 16, 49 CFR 40, and 33 CFR 95. Vessel must provide proof of pre-employment testing, company program, training, and any additional required documentation to demonstrate fully compliant program prior to the carriage of passengers. 46 CFR 185.100
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 September 2024
Resolution: Received docs for DAPI audit
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 August 2023 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel has not completed drydock examination in the past two years. Conduct satisfactory drydock examination prior to the carriage of passengers. 46 CFR 176.600(c)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2023
Resolution: Conducted a satisfactory drydock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 August 2023 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Port engine is inoperable. Repair engine to the satisfaction of the marine inspector. 46 CFR 182.200(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2023
Resolution: Port engine has been repairs and satisfactory sea trials conducted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 April 2023 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. STBD fuel shutoff valve is wasted and inoperable from reach-rod without breaking apart. Replace fuel shutoff valve assembly and complete operational fuel shutoff test to satisfaction of marine inspector. 46 CFR 182.455 (b) (4)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2023
Resolution: Capt. provided photos of new inline ball valve assembly and a video of satisfactory operation of valve using attached reach rod.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 April 2023 Resolved
Portable and semi-portable extinguishers must be inspected and maintaned in accordance with NFPA 10: (iv) The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility must perform the required inspections, maintenance procedures, and hydrostatic pressure tests. 10 bc portable fire extinguisher at upper operating station requires annual servicing. Provide satisfactory evidence of required annual maintenance and servicing to satisfaction of Marine Inspector. 46 CFR 176.810 (b) (1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2023
Resolution: New 10 bc extinguisher for upper wheelhouse purchased and installed to satisfaction of Marine Inspector. Satisfactory fire servicing report and invoice provided via email.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 April 2023 Resolved
Vessels shall be inspected for compliance with the standards required by this subchapter. For items not covered by standards in this subchapter, inspection shall be in accordance with the standards acceptable to the Officer in Charge, Marine Inspection, as good marine practice. Port Side fuel fill fitting on deck has a wasted gasket, allowing water intrusion to mildly saturate deck. Deck is showing some small signs of furring. Replace gasket to ensure satisfactory seal between deck fitting and deck at Port Side Fuel Fill. 46 CFR 176.25-1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2023
Resolved 13 July 2023
Resolution: Sealed all deck fittings, eliminating water intrusion.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 April 2023 Resolved
Electrical equipment on a vessel must be installed and maintaned to: (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment and shock. Exposed dead end wires visible at upper operating station. Remove dead-end wires station to satisfaction of Marine Inspector. 46 CFR 183.200 (b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 13 July 2023
Resolution: Dead end wires removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 April 2023 Resolved
All machinery and equipment must be and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Hazardous condition exists in engine room from excessive gases present from "blow-by" system. Vessel shall either repair engine or provide technician/diagnostics report from a qualified Marine Diesel Technician of safe and effective operation of both Main Diesel Engines to the satisfaction of Marine Inspector. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2023
Resolved 13 July 2023
Resolution: Installed Solberg blow-by filtration system, eliminating the blow-by gas completely.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 27 April 2022 Resolved
Flexible hose runs shall be visible, easily accessible, and shall not penetrate watertight bulkheads. Metallic fittings must be installed where flexible fuel hose penetrates the bulkhead. 46 CFR 182.20-40(a)(2)(i) OLD T.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 26 May 2022
Resolution: Photograph provided of metallic fitting.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 April 2022 Resolved
Approval of bowls of other than steel construction will specify if a flame shield is required. Racor fuel strainers in the lazarette do not have drip pans as per manufacturer design.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 26 May 2022
Resolution: Photograph provided of drip pan installation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 April 2022 Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Aft bilge strainer is not 3 times the area of the suction pipe.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2022
Resolved 10 May 2022
Resolution: New bilge strainer installed with photograph provided.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 27 April 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to: minimize accidental personnel contact with energized parts. Four dead end wires were found under the pilot house helm.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 26 May 2022
Resolution: Photograph provided of capped dead-end wires.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 April 2022 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Anchor and stern light is not operational.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 26 May 2022
Resolution: Photograph provided of operational anchor and stern light.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 April 2022 Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. Fire extinguishers were not permanently affixed to the bulkheads.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2022
Resolved 10 May 2022
Resolution: Portable fire extinguishers have been mounted to the bulkhead with an acceptable bracket. Photograph was provided.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 27 April 2022 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Marking on fuel shutoff not present.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2022
Resolved 10 May 2022
Resolution: Satisfactory markings have been installed. Photograph was provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 April 2022 Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Retroreflective tape was missing from ring life buoy.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2022
Resolved 10 May 2022
Resolution: Retroflective material has been affixed to the ring life buoy. Photograph was provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 April 2022 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters. Life jacket quantity was not labeled.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2022
Resolved 10 May 2022
Resolution: Life jacket quantity has been labeled. Photograph was provided.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 September 2021 Resolved
A pre-engineered fixed gas fire extinguishing system must: Be approved by the Commandant; Be capable of manual actuation from outside the space in addition to automatic actuation by a heat detector; Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space; and be installed in accordance with the manufacturer's instructions. A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station: (1) A light to indicate discharge; (2) An audible alarm that sounds upon discharge; and (3) A means to reset devices used to automatically shut down ventilation systems and engines. The pre-engineered Fireboy gas fire extinguishing system for the main machinery space, was not equipped with a means to manually activate the system, or a means to automatically shut down the engines that draw intake air from within the protected space. The owner shall install a means to manually activate the system from outside the protected space, and a means to automatically secure the engines that draw intake air from within the protected space upon system activation. All installations shall be in accordance with the approved Fireboy installation manual.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2021
Resolved 27 April 2022
Resolution: Verified proper installation and operation of Fireboy.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 June 2021 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural examination at least once every two years. The vessel has not undergone the required Coast Guard drydock and internal structural examination for more than two years. The vessel is limited to service as an un-inspected passenger vessel carrying 6 or less passengers with at least one for hire, or a recreational vessel, until it undergoes the required drydock and internal structural examination, or is granted an drydock examination extension by the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2021
Resolved 9 June 2021
Resolution: Coast Guard Sector San Francisco granted dry-dock extension until 30 June 2021.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 21 September 2020 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. The FCC Safety Radio Certificate was missing. A new FCC Safety Radio Certificate must be obtained and placed onboard the vessel.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 November 2020
Resolved 9 November 2020
Resolution: A valid FCC Safety Radio Certificate was obtained for the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 September 2020 Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility must perform the required inspections, maintenance procedures, and hydrostatic pressure tests. A tag issued by a qualified servicing organization, and attached to each extinguisher, may be accepted as evidence that the necessary maintenance procedures have been conducted. No record of monthly maintenance being performed on portable fire extinguishers. Provide evidence that contains a record of all monthly maintenance being performed on portable fire extinguishers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 September 2020
Resolved 9 November 2020
Resolution: Evidence was provided that all fire extinguishers were being maintained IAW with regulations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 September 2020 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. The Port fuel tank supply line shutoff valve was severally corroded and not functional. Install new fuel shutoff valve on the port fuel tank supply line.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 September 2020
Resolved 9 November 2020
Resolution: The inoperable fuel supply shut off valve on the port fuel tank was repaired.

Recorded names · 1

MALIA KAI (2023–2025). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.