MAURY USCG vessel records
← All vessels

HAFNIA PRESTIGE

HAFNIA PRESTIGE is a 2016 tank ship. The Coast Guard has recorded 7 inspections since 2018, most recently in March 2026, along with 2 deficiencies and 2 operational controls.

Records from 2018 to 2026. Most recent: operational control imposed, 27 March 2026.

Built
2016
Last inspected
27 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9760225
9V7902
1427855
Flag
SINGAPORE
Maury page id
psix-1427855

Inspections, by type

…with no type recorded2
Years with a record 4 calendar years (2018–2026)
The 7 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it43142 - Convention (Subpart B), Gross Ton
74996 - Dead Weight, Metric Ton
89195 - Displacement, Metric Ton
22260 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 7

27 March 2026 PSC B · COC-TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8327912
27 March 2026 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8332845
26 March 2026 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8340450
28 May 2022 PSC B · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7461006
7 July 2020 Ballast Water Examination · PSC B · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6999188
2 July 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6993280
31 July 2018 PII Safety Exam · ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6496284

Deficiency record · 2

14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 28 May 2022 Resolved
FOLLOWING INSTALLATION, THE MASTER, OWNER, OPERATOR, OR PERSON IN CHARGE OF THE VESSEL MUST PROPERLY MAINTAIN THE BWMS IN ACCORDANCE WITH ALL MANUFACTURER SPECIFICATIONS. VESSEL BALLAST WATER MANAGEMENT SYSTEM IS INOPERABLE. VESSEL SHALL NOT DISCHARGE BALLAST WATER INTO U.S.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 June 2022
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 28 May 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed O2 analyzers could not calibrate span gas and nitrogen gas. SOLAS(20) I 11(b)
Action required: 10 - Deficiency Rectified
Resolved 28 May 2022
Resolution: PSCO observed satisfactory operation of O2 analyzers prior to departure from vessel.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.