Records from 2016 to 2026. Most recent: inspection, 3 June 2026.
Documentation record
Registered dimensions (L × B × D)31.0 ft × 10.5 ft × 6.0 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS, INC. · CAPE MAY COURTHOUSE, NJ, UNITED STATES · built 2017
Hull materialFRP (Fiberglass)
PropulsionInboard/Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portPENSACOLA BEACH, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 15 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 17
3 June 2026
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8367832
21 April 2025
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8105271
2 January 2025
Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8056861
21 May 2024
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7916692
18 May 2023
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7687028
11 January 2023
Drydock Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7611030
11 March 2022
Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7412780
24 May 2021
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7205352
19 January 2021
Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7127122
21 May 2020
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6955466
3 June 2019
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6702621
29 March 2019
Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6651997
12 July 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6476773
27 February 2018
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6362501
3 November 2017
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6300033
27 March 2017
DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6112192
29 November 2016
Administrative Inspection · Internal Structural Exam · Initial Certification · Construction Oversight · Plan Review "T" Boat · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6065613
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 June 2026
Resolved
A number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided. MI found only one child life jacket on board. Vessel is restricted to carriage of only one child until another child sized life jacket is provided.
46 CFR 180.71(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 July 2026
Resolution: Vessel provided proof of new child life jacket.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 3 June 2026
Resolved
Any vessel of at least five net tons which engages in coastwise trade, unless exempt under § 67.9(c), must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. MI found the CoD on board to be expired.
46 CFR 67.7
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 June 2026
Resolution: Received proof of new COD
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 May 2024
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure and have either:(1) A pressure type connector on each conductor;(2) A solder lug on each conductor;(3) A splice made with a pressure type connector to a flexible lead or conductor; or(4) A splice that is soldered, brazed, or welded to a flexible lead or conductor. Spliced electrical cables in engine compartment were not in an enclosure. Repair.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2024
Resolved 23 May 2024
Resolution: Received photo of junction box installed in engine room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 May 2023
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. The aft bilge pump indicator light does not turn off when the pump is not operating.
Extended to 30 days due to difficulting getting tech to repair. Operator is not currently using this vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 9 June 2023
Resolution: Received video of functioning bilge pump indicator light.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 27 May 2021
Resolved
Vessels bilge high level alarms and pumps were inop.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 May 2021
Resolved 2 June 2021
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 27 May 2021
Resolved
Vessel did not have a valid Safety Radiotelephony Cert. Vessel is limited to 1000 ft. from shore while carring passengers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 May 2021
Resolved 2 June 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 20 January 2021
Resolved
The construction and arrangement of a vessel must allow for safe operation of a vessel with consideration to a seaworth hull. At dry dock, observed vessel engine intake thru hull was missing the strainer cage on bottom side of hull exposing 4 holes. Repair/replace to original construction strength and integrity.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 February 2021
Resolution: Recieved picture of stainger cage installed and sealer around the cage, meeting the initial construction and watertight integrity.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 March 2019
Resolved
Vessel drydock date has passed. Vessel must complete a hull examination once every two years prior to the exam drop-dead date of 31JAN of the exam year as listed on the COI. Vessel shall not carry passengers until the hull examination is completed.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2019
Resolution: Completed DryDock Exam
Personnel › Training › Familiarization Training
Issued 15 March 2017
Resolved
Owner/Operator of vessel must conduct new to xone inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 July 2018
Resolution: Completed training.
Personnel › Training › Familiarization Training
Issued 15 March 2017
Resolved
Owner/Operator of vessel must conplete worklist prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 July 2018
Resolution: Completed worklist.
Stability › Incline Test › General
Issued 15 March 2017
Resolved
Owner/Operator of vessel must obtain a stability letter prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 July 2018
Resolution: Stability letter has been obtained.