MAURY USCG vessel records
← All vessels

STELLAR RIONI

STELLAR RIONI is a 2017 freight ship. The Coast Guard has recorded 10 inspections since 2017, most recently in June 2026, along with 2 deficiencies and 2 operational controls.

Records from 2017 to 2026. Most recent: inspection, 15 June 2026.

Built
2017
Last inspected
15 June 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9780304
1428304
Flag
PANAMA
Maury page id
psix-1428304

Inspections, by type

…with no type recorded2
Years with a record 5 calendar years (2017–2026)
The 10 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it24655 - Convention (Subpart B), Gross Ton
38230 - Dead Weight, Ton
46891 - Displacement, Ton
12351 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 10

15 June 2026 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8397454
12 June 2026 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8403058
2 November 2021 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7343865
14 September 2019 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6813472
26 June 2019 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6726375
18 May 2019 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6671836
26 April 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6391516
23 April 2018 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6397800
2 August 2017 Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6226637
7 February 2017 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6077979

Deficiency record · 2

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 May 2019 Resolved
0725 Where a fixed fire system is installed, it shall meet the requirements of the relevant regulations of this chapter and the Fire Safety System Code; A quantity of spare sprinkler heads shall be provided on the ship. No spare sprinkler heads were aboard ship. SOLAS 74 (Cons 2014) II-2/10.4.1.2 FSS Code(2015)8/2.3.1.2 - 17.a.c.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2019
Resolved 19 May 2019
Resolution: Class has provided a letter of dispensation for the deficiency. Copy of letter has been uploaded.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 18 May 2019 Resolved
0750 The following fire protection systems shall be kept in good working order so as to assure their required performance if a fire occurs; structural fire protection including fire resisting divisions. The lower engineering - forward bulkhead was missing approximately 1.5 sq feet of A-60 boundary due to wasting. SOLAS 74 (Cons 2014) II-2/14.2.1.1.1 - 40.a.c
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 June 2019
Resolution: Received, reviewed and accepted class report from class NK stating deficiency was rectified by replacing insulation.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.