MAURY USCG vessel records Sign in
← All vessels

SALISH SEA

SALISH SEA is a 1976 passenger vessel (inspected). The Coast Guard has recorded 66 inspections since 1986, most recently in March 2026, along with 52 deficiencies and 1 operational control.

Records from 1986 to 2026. Most recent: inspection, 25 March 2026.

Built
1976
Last inspected
25 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCY9101
142873
Flag
UNITED STATES
367395870
Maury page id
psix-142873

Inspections, by type

…with no type recorded4
Years with a record 37 calendar years (1986–2026)
The 66 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)48.0 ft × 15.7 ft × 6.7 ft
Registered tonnagegross 36 / net 28
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA MARINE INDUSTRIES · SEATTLE, WA, UNITED STATES · built 1976
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBELLINGHAM, WA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 16 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it36 - Regulatory (Subpart C or D), Gross Ton
28 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCY9101MMSI 367395870 · active · compulsorily equipped · granted 22 December 2018, expires 2 March 2029
WCX4910MMSI not assigned · expired · compulsorily equipped · granted 19 May 1997, cancelled 22 July 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 66

25 March 2026 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8299763
2 April 2025 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8103650
5 December 2024 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8043848
20 March 2024 Deficiency Check · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7882086
11 May 2023 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7714119
15 March 2023 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7652259
8 March 2023 Internal Structural Exam · Drydock Extension
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7647969
24 March 2022 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7418358
24 March 2021 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7163090
17 March 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7150308
26 June 2020 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6980097
13 March 2019 Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6640581
4 April 2018 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6384093
11 April 2017 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6121263
14 March 2017 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6105597
1 April 2016 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5843719
28 March 2014 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4822364
10 December 2011 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4205556
1 December 2010 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3902347
26 March 2010 Annual Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3703609
23 March 2009 Internal Structural Exam · Deficiency Check · COI Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3438406
11 January 2008 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3128737
14 September 2007 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3057583
6 April 2007 Hull Examination · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2903010
31 January 2007 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2798514
6 October 2005 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2509815
1 April 2005 Hull Examination · Internal Structural Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2324596
7 October 2004 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2214944
20 October 2003 Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1932121
30 June 2003 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1831286
22 April 2003 Hull Examination · Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1769662
15 April 2002 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1605291
16 April 2001 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1441821
9 April 2001 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1435219
4 April 2000 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1465543
28 April 1999 Hull Examination · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1399101
23 April 1998 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1128543
1 April 1998 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1458507
11 April 1997 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1385977
9 April 1997 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1374944
9 May 1996 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1083335
9 April 1996 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1353897
16 May 1995 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 925136
21 April 1995 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1442248
10 April 1995 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1371045
12 April 1994 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1170386
19 June 1993 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 828719
12 May 1993 Re-Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1385074
27 October 1992 Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1463745
18 May 1992 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 950400
6 March 1992 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1445914
10 December 1991 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1259781
12 November 1991 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1254050
15 July 1991 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1248883
14 June 1991 Inclining Experiment
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 896848
31 May 1991 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 910695
29 May 1991 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 909482
16 June 1990 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1230097
16 May 1990 COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 930185
4 May 1990 Hull Examination
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 930187
1 May 1989 Administrative
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1204291
26 April 1989 Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 896493
21 September 1988 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1351396
10 December 1987 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1314777
17 September 1987 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1001109
5 August 1986 Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1001142

Deficiency record · 52

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 March 2026 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. MI observed numerous [name withheld], enclosed cell type life jackets to be in unserviceable condition. O/o is to repair or replace life jackets. 46 CFR 176.808(b) 50c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2026
Resolved 26 March 2026
Resolution: O/o replaced life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 March 2026 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. MI observed one ring lifebuoy to be in unserviceable condition. O/o is to replace ring life buoy. 46 CFR 176.808(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2026
Resolved 31 March 2026
Resolution: O/o replaced ring life buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 March 2026 Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). MI observed one ring lifebuoy without retro-reflective material. Retro-reflective materials of a sufficient width (approximately 5 cm) should be applied around or on both sides of the body of the lifebuoy at four evenly-spaced points. 46 CFR 185.604(i) IMO Resolution A.658(16).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2026
Resolved 31 March 2026
Resolution: O/O add retro-reflective tape to lifebuoy.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 March 2024 Resolved
One length of fire hose shall be provided for each fire hydrant required. Vessel did not have a fire hose meeting the requirements of the regulations on board at the time of inspection. 46 CFR 181.15-10
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2024
Resolved 27 March 2024
Resolution: Fire house was placed into service on vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2024 Resolved
The marine inspector shall examine and test the following items to the extent necessary to determine that they are in proper operating condition, safe electrical condition, and fit for the service for which they are intended: Electrical Cable. Marine Inspector observed improperly bonded and disconnected ground wiring in engineering spaces. 46 CFR 176.25-15 (a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2024
Resolved 27 March 2024
Resolution: Vessel addressed the improper bonding and grounding in the engineering spaces. Marine inspector verified space was safe and properly bonded and grounded.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 March 2024 Resolved
The marine inspector shall examine and test the following items to the extent necessary to determine that they are in proper operating condition, safe electrical condition, and fit for the service for which they are intended: Fire protective devices. The fire detection alarm was not properly secured in the engine compartment. 46 CFR 176.25-15 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2024
Resolved 27 March 2024
Resolution: Fire detection alarm was secured to proper fittings. All Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 March 2024 Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retro-reflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). Ring Buoy: (Starboard Side, Upper Deck) was missing retro-reflective tape. 46 CFR 185.604 (i)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2024
Resolved 27 March 2024
Resolution: Lifering was fitted with retro-reflective tape. All Sat
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 20 March 2024 Resolved
Rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crews. Marine Inspector observed door latch:(Port Side, Aft) was unable to secure properly. 46 CFR 177.35-1 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2024
Resolved 15 January 2025
Resolution: Door latch was replaced and is now able to secure the door.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 24 March 2021 Resolved
Federal Communications Commission Safety Radiotelephony Certificate is expired, current certificate is required.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 April 2021
Resolved 31 March 2021
Resolution: Presented current certificate.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 24 March 2021 Resolved
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 April 2021
Resolved 31 March 2021
Resolution: Presented operators permit.
Engineering › Bilge Water Management System › Valve
Issued 1 April 2016 Resolved
Repair bilge line for aft engine room bilge pump. 46 CFR 182.01-5 and 182.25-5
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 1 April 2016
Resolution: Master contacted inspectors after inspection and notified of issue and repair.
Engineering › Bilge Water Management System › Valve
Issued 28 March 2014 Resolved
Install positive shutoff valves at the hull penetration on overboard discharge piping for all electric bilge pumps. Must be conducted prior to completion of 2015 drydock. Ref. 46CFR182.520(e)(7)
Action required: 705 - Other - as specified
Due 18 March 2015
Resolved 18 March 2015
Resolution: Installed positive shutoff valves, all sat.
Lifesaving › Lifefloat › Float-free Link
Issued 28 March 2014 Resolved
Renew weak link on starboard lifefloat.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 April 2014
Resolved 25 April 2014
Resolution: Vessel purchased and installed weak link with proper identification tag.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 28 March 2014 Resolved
Install an approved fire detection system in the machinery space. Ref. 46CFR181.400(c)(1)
Action required: 705 - Other - as specified
Due 20 April 2014
Resolved 25 April 2014
Resolution: Vessel installed UL approved heat detector in machinery space. Operational test sat.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 31 March 2010 Resolved
Vessel required FCC Safety Radiotelephone certificate IAW 46CFR184.25. Vessels certificate is expired. Obtain valid FCC certificate IAW cite.
Action required: 705 - Other - as specified
Due 30 April 2010
Resolved 23 April 2010
Resolution: Vessel representative provided FCC documentation as required.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 31 March 2009 Resolved
Cracks in Buoyant Apparatus surface. Repair Buoyant apparatus IAW 46 CFR 185.700.
Action required: 705 - Other - as specified
Due 31 March 2009
Resolved 14 May 2009
Resolution: Repairs completed on Buoyant Apparatus with repair kit.
Electrical › Lighting (service) › Lighting Fixture
Issued 9 October 2007 Resolved
Missing proper light fixture covers in main passenger area.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 November 2007
Resolved 11 January 2008
Resolution: Replace light covers/ lighting as neccessary.
Lifesaving › Hand Flares › Marking
Issued 9 October 2007 Resolved
Properly label flare box "Distress Signals" as required by 46CFR185.614.
Action required: 705 - Other - as specified
Due 9 November 2007
Resolved 17 October 2007
Resolution: Labeled flare box
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 9 October 2007 Resolved
Properly label location of Child PFDs as required in 46CFR180.78.
Action required: 705 - Other - as specified
Due 9 November 2007
Resolved 17 October 2007
Resolution: Put up an appropriate label for the Child PFDs.
Lifesaving › Lifebuoys › Serviceable
Issued 9 October 2007 Resolved
Replace aft lifebuoy w/ proper line attached as per 46CFR180.70.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 November 2007
Resolved 17 October 2007
Resolution: Replaced lifebuoy.
Communications › Radio Communications › VHF Radiotelephone
Issued 9 October 2007 Resolved
Provide Emergency broadcast placard and post appropriately per 46CFR184.506.
Action required: 705 - Other - as specified
Due 9 November 2007
Resolved 17 October 2007
Resolution: Posted emergency broadcast placard.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 9 October 2007 Resolved
Provide and appropriately display MARPOL V and Oil pollution placards as per 33CFR151.59 and 33CFR155.450 respectively.
Action required: 705 - Other - as specified
Due 9 November 2007
Resolved 17 October 2007
Resolution: Displayed MARPOL V and Oil pollution placards.
Electrical › Lighting (service) › Lighting Feeder
Issued 9 October 2007 Resolved
Clean connections for Stbd running light to ensure proper connection. (Did not come on during first attempt.)
Action required: 705 - Other - as specified
Due 9 November 2007
Resolved 9 October 2007
Resolution: Cleaned connections as requested.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 9 October 2007 Resolved
Vessel missing Emergency instructions as per 46CFR185.510.
Action required: 705 - Other - as specified
Due 9 November 2007
Resolved 17 October 2007
Resolution: Posted Emergency Instructions.
Construction/Loadline › Penetrations › Valve Flange
Issued 6 April 2007 Resolved
Sea valve in the head not capped or properly attached to sanitation system.
Due 6 April 2007
Resolved 6 April 2007
Construction/Loadline › Penetrations › Valve Flange
Issued 6 April 2007 Resolved
All through hull hose connections are not double clamped.
Due 6 April 2007
Resolved 6 April 2007
Engineering › Bilge Water Management System › Hose
Issued 6 April 2007 Resolved
Bilge overboard hose connection is rusted and leaking.
Due 6 April 2007
Resolved 6 April 2007
Construction/Loadline › Structures › Scuttle
Issued 6 April 2007 Resolved
Rot found in fiberglass sandwich construction around the forward scuttle. Make proper repair to fiberglass and wood around the forward scuttle.
Due 27 April 2007
Resolved 11 May 2007
Lifesaving › Buoyant Apparatus › Serviceable
Issued 10 October 2006 Resolved
All lifefloats must be serviced or replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 January 2007
Resolution: Replaced all lifefloats.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 October 2006 Resolved
COI not posted.
Due 10 November 2006
Resolved 10 October 2006
Operations/Management › Drills/Instruction › Abandon Ship
Issued 10 October 2006 Resolved
Missing life jacket donning placard.
Due 10 November 2006
Resolved 31 January 2007
Resolution: Vessel operator stated life jacket donning placard is posted.
Personnel › Training › First Aid/CPR
Issued 10 October 2006 Resolved
First Aid/ CPR card expired. Must provide proof of refresher training.
Due 10 November 2006
Resolved 31 January 2007
Resolution: Vessel operator stated First Aid/ CPR cards are in employee''''s files.
Fire Fighting › Remote Fuel Shutoff › General
Issued 10 October 2006 Resolved
Fuel shut offs must be clearly labeled.
Due 10 November 2006
Resolved 10 October 2006
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 20 October 2003 Resolved
The waterlight was not properly attached to the ring buoy.
Due 5 November 2003
Resolved 5 November 2003
Navigation › Piloting/Steering › Magnetic Compass
Issued 20 October 2003 Resolved
There were no means to illuminate the magnetic compass.
Due 5 November 2003
Resolved 5 November 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 20 October 2003 Resolved
The operating station panel had open penetrations that needed to be capped.
Due 5 November 2003
Resolved 5 November 2003
Construction/Loadline
Issued 9 April 1996 Resolved
INSTALL CHECK VALVE IN GENERATOR EXHAUST AT SPOOL PIECE.
Condition: Unknown
Due 9 April 1996
Resolved 9 April 1996
Accommodation/Occupational Safety
Issued 9 April 1996 Resolved
PROVIDE MEANS OF INDICATING WHEN MSD IS MORE THAN 3/4 FULL TO THE SATISFACTION OF THE COGNIZANT OCMI._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 April 1996
Resolved 9 April 1996
Construction/Loadline
Issued 10 April 1995 Resolved
INSTALL RETAINING CHAIN ON HATCH TO STEERING COMPT.
Condition: Unknown
Due 10 April 1995
Resolved 10 April 1995
Fire Fighting
Issued 10 April 1995 Resolved
PROCURE HAND OPERATED FIRE/BILGE PUMP WITH SUFFICIENT HOSE.
Condition: Unknown
Due 10 April 1995
Resolved 10 April 1995
Engineering
Issued 10 April 1995 Resolved
ADJUST/RENEW PACKING GLAND FOR PORT SHAFT.
Condition: Unknown
Due 10 April 1995
Resolved 10 April 1995
Engineering
Issued 10 April 1995 Resolved
INSTALL FLAME SCREEN IN STBD. F/O TANK VENT.
Condition: Unknown
Due 10 April 1995
Resolved 10 April 1995
Electrical
Issued 10 April 1995 Resolved
INSTALL PROTECTIVE COVER FOR CENTERLINE LIGHT IN ENG. RM.
Condition: Unknown
Due 10 April 1995
Resolved 10 April 1995
Lifesaving
Issued 10 April 1995 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 10 April 1995
Resolved 10 April 1995
Fire Fighting
Issued 18 May 1992 Resolved
SERVICE FIXED AND PORTABLE FIRE EXTINGUISHERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 June 1992
Resolved 27 May 1992
Lifesaving
Issued 18 May 1992 Resolved
REPLACE FLOAT FREE LINK ON 8 MAN BOUYANT APPARATUS WITH PROPER SIZE (100- 134LB)
Condition: Unknown
Due 1 June 1992
Resolved 27 May 1992
Construction/Loadline
Issued 14 June 1991 Resolved
PROVIDE NON-RETURN/SELF BAILING SCUPPERS IN COCKPIT AREA PER 46 CFR 171.145
Condition: Unknown
Due 15 July 1991
Resolved 15 July 1991
Documentation
Issued 29 May 1991 Resolved
PROVIDE MARINE DOCUMENT. VESSEL MAY NOT CARRY PASSENGERS FOR HIRE UNTIL THIS REQUIREMENT IS MET.
Condition: Unknown
Due 29 May 1991
Resolved 29 May 1991
Engineering
Issued 29 May 1991 Resolved
REPLACE DIESEL FUEL SUPPLY HOSES TO ENGINES WITH USCG APPROVED HOSE ASSEMBLIES NO GREATER THAN 30" IN LENGTH. ALL ELSE TO BE COPPER TUBING. _x001C__x001C_ _x001C_
Condition: Unknown
Due 29 May 1991
Resolved 29 May 1991
Electrical
Issued 16 May 1990 Resolved
PROVIDE AND INSTALL A VOLTMETER AND AMMETER FOR THE AC GENERATOR.
Condition: Unknown
Due 16 May 1990
Resolved 16 May 1990
Engineering
Issued 16 May 1990 Resolved
PROVIDE AND INSTALL BILGE PUMP FOR THE FORWARD COMPARTMENT.
Condition: Unknown
Due 16 May 1990
Resolved 16 May 1990
Construction/Loadline
Issued 16 May 1990 Resolved
PROVIDE AND INSTALL EXHAUST VENTILATION DUCTING WHICH IS OF RIGID PERMANENTCONSTRUCTION EXTENDING TO A POINT CLOSE TO THE BOTTOM OF THE ENGINE ROOM BILGE.
Condition: Unknown
Due 16 May 1990
Resolved 16 May 1990

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.