Records from 2017 to 2026. Most recent: inspection, 28 July 2026.
Inspection history · 13
28 July 2026
Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8449193
17 April 2026
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8317299
7 March 2026
Examination of Repairs
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8323378
25 May 2025
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8178675
7 March 2025
Drydock Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8106564
16 June 2024
Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7936127
6 May 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7908151
28 March 2024
Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7886701
31 March 2023
COI Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7660359
11 April 2022
COI Inspection · Drydock Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7425415
8 March 2021
Drydock Exam · COI Inspection · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7151875
13 July 2019
Administrative Inspection · Initial Certification · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6752582
2 January 2017
Construction Oversight · Simplified Stability Test
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6108211
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 March 2024
Resolved
First aid equipment was found with expired equipment.
Replace first aid kits.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2024
Resolution: Vessel had a new first aid kit onboard
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 March 2024
Resolved
During the overpressure stress test, the vessel did not hold pressure in the chambers being measured, indicating a slow but significant leak between the baffles.
To receive dry dock credit; identify the source of the leaks, propose adequate repairs and once repairs are executed, make the vessel available for additional pressure testing of 1.5 times the working pressure for 10 minutes verified via calibrated pressure gauge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2024
Resolution: Vessel had sponson repaired by zodiac with documentation. I observed each chamber inflated idividually with no bleed over to other chambers
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 March 2024
Resolved
Radar reflector was reported as warped and is on order to be replaced. Send proof of replacement.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2024
Resolution: Vessel had new radar reflector onboard
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 March 2024
Resolved
The batteries in the portable lights were corroded and the portable lights were no longer operations. Replace the flashlights and send proof of the replacement.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2024
Resolution: Vessel had a new flash light and all portable lights operated as designed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 March 2024
Resolved
The line for the ring buoy line is wasted. Replace ring buoy line and send proof of replacement to the OCMI to clear the deficiency.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2024
Resolution: Ring buoy was replaced along with grab lines.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 July 2019
Resolved
Provide First aid kit at meeting 46 CFR 160.041
Action required: 10 - Deficiency Rectified
Resolved 13 July 2019
Resolution: Vessel correctly stocked first aid as per 46 cfr 160.041
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 July 2019
Resolved
Properly attach light to life ring
Action required: 10 - Deficiency Rectified
Resolved 13 July 2019
Resolution: Vessel correctly attached light ot ring bouy
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 13 July 2019
Resolved
Provide radar reflector as per D17INST 16711 date
14DEC2018 before next 2020 operating season in AK
Action required: 705 - Other - as specified
Due 1 April 2020
Resolved 1 April 2021
Resolution: Verified equipment onboard.