Records from 2017 to 2026. Most recent: inspection, 25 February 2026.
Inspection history · 18
25 February 2026
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 8316519
6 May 2025
Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8129360
19 February 2025
Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8081459
8 May 2024
Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7908524
28 March 2023
Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7658169
28 February 2023
Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7642994
4 March 2022
Deficiency Check · COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7405780
23 June 2021
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7233732
7 June 2021
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7215555
4 February 2021
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7135579
12 June 2020
Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6974289
11 July 2019
Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6762999
17 June 2019
Administrative Inspection · Construction Oversight · Plan Review "T" Boat · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6762985
21 February 2019
Annual Inspection · Hull Examination · Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6629968
29 May 2018
Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6427798
21 May 2018
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6419525
21 March 2017
Administrative Inspection · In-Service Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6084816
2 January 2017
Construction Oversight · Initial Certification
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6064691
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 May 2025
Resolved
A vessel on a rivers route must carry three hand held red flares and three hand held orange smoke signals. The vessel is missing three distress signals.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 9 May 2025
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 March 2022
Resolved
A vessel must have navigation lights that are in compliance with the inland navigation rules; the port and stbd running lights are not operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 March 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 March 2022
Resolved
The name and hailing port of the vessel must be marked of the stern in 4" block letters; the prescribed markings are not in place.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 March 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 June 2021
Resolved
46CFR185.604 (b)-Each lifejacket must be marked in clearly legible block capital letters with the vessels name. Update lifejacket's to refelct new name.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2021
Resolved 16 June 2021
Resolution: Owner submitted pictures showing that the life jackets have been fixed. See attached in documents.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 June 2021
Resolved
46CFR 183.420- All vessels must have navigation lights that are in compliance with the applicable section of the intl/inland nav rules.
Action required: 60 - Rectify deficiencies prior to movement
Due 11 June 2021
Resolved 11 June 2021
Resolution: Light replaced with pictures sent in-see docuemntation.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 June 2020
Resolved
The vessel is required to have an alcohol testing device on board to enable testing of crew members in the event of a serious marine incident; the existing saliva test kits are expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 June 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 June 2020
Resolved
Water light batteries must be replaced annually, in accordance with manufacturer’s instructions; the existing battery has not been replaced in over one year.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 June 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 June 2020
Resolved
Each life buoy must be marked with Type II reflective material approved IAW 164.018; the existing ring buoy is new and is not properly marked with reflective material.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 June 2020
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 June 2020
Resolved
A vessel must carry a first aid kit, approval number 160.041, or a kit with an equivalent contents; the existing kit is not an approved type.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 June 2020
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 June 2020
Resolved
The installation of each portable fire extinguisher must be to the satisfaction of the OCMI; the extinguisher for the operating station has been renewed and is not properly mounted.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 June 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 June 2019
Resolved
Fuel hose does not indicate specifications; provide proof that the fuel hose is USCG Type A appproved.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 August 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 June 2019
Resolved
The fuel system is not equipped with a strainer, install a fuel strainer IAW 46 CFR 182.455 (b) (6).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 June 2019
Resolved
New wire runs under the operating station are not protected with overcurrent device; install overcurrent protection where needed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 June 2019
Resolved
There too many wire connections on the battery terminal; install a bus bar for the ground wire connections.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 August 2019
Personnel › Certificates/Documents/Licenses › License, Master
Issued 22 May 2018
Resolved
Provide licensed captain and crew for drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 June 2018
Resolution: A properly licensed Capt was onboard and conducted drills.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 22 May 2018
Resolved
Provide documentation that crew is enrolled in drug consortium and has conducted pre-employment testing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 June 2018
Resolution: Documentation of pre-employment testing provided.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 22 May 2018
Resolved
Provide in date alcohol test strips.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 June 2018
Resolution: Test strips have been ordered and POC stated they will be placed onboard.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 22 May 2018
Resolved
Provide proof of overcurrent protection for paddle-wheel winch. If none, install in line fuse as close to battery as possible.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 June 2018
Resolution: POC stated that the builder provided info that the winch has overcurrent incorporated into the unit.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 February 2017
Resolved
COMPLETE A NEW TO ZONE INSPECTION AND THE ATTACHED WORKLIST DATED 10 FEB 2017 TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO THE CARRIAGE OF PASSENGERS.
Action required: 705 - Other - as specified
Due 10 March 2017
Resolved 22 May 2018
Resolution: Outstanding Def from previous unit.