MAURY USCG vessel records
← All vessels

TIKI TOON

TIKI TOON is a 2017 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2017, most recently in February 2026, along with 19 deficiencies.

Records from 2017 to 2026. Most recent: inspection, 25 February 2026.

Built
2017
Last inspected
25 February 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 February 2026
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2017–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1429618
Flag
UNITED STATES
Maury page id
psix-1429618

Documentation record

Tonnage as PSIX records it2 - Simplified, Gross Ton
2 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 18

25 February 2026 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 8316519
6 May 2025 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8129360
19 February 2025 Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8081459
8 May 2024 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7908524
28 March 2023 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7658169
28 February 2023 Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7642994
4 March 2022 Deficiency Check · COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7405780
23 June 2021 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7233732
7 June 2021 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7215555
4 February 2021 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7135579
12 June 2020 Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6974289
11 July 2019 Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6762999
17 June 2019 Administrative Inspection · Construction Oversight · Plan Review "T" Boat · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6762985
21 February 2019 Annual Inspection · Hull Examination · Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6629968
29 May 2018 Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6427798
21 May 2018 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6419525
21 March 2017 Administrative Inspection · In-Service Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6084816
2 January 2017 Construction Oversight · Initial Certification
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6064691

Deficiency record · 19

11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 May 2025 Resolved
A vessel on a rivers route must carry three hand held red flares and three hand held orange smoke signals. The vessel is missing three distress signals.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 9 May 2025
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 March 2022 Resolved
A vessel must have navigation lights that are in compliance with the inland navigation rules; the port and stbd running lights are not operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 March 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 March 2022 Resolved
The name and hailing port of the vessel must be marked of the stern in 4" block letters; the prescribed markings are not in place.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 March 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 June 2021 Resolved
46CFR185.604 (b)-Each lifejacket must be marked in clearly legible block capital letters with the vessels name. Update lifejacket's to refelct new name.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2021
Resolved 16 June 2021
Resolution: Owner submitted pictures showing that the life jackets have been fixed. See attached in documents.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 June 2021 Resolved
46CFR 183.420- All vessels must have navigation lights that are in compliance with the applicable section of the intl/inland nav rules.
Action required: 60 - Rectify deficiencies prior to movement
Due 11 June 2021
Resolved 11 June 2021
Resolution: Light replaced with pictures sent in-see docuemntation.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 June 2020 Resolved
The vessel is required to have an alcohol testing device on board to enable testing of crew members in the event of a serious marine incident; the existing saliva test kits are expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 June 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 June 2020 Resolved
Water light batteries must be replaced annually, in accordance with manufacturer’s instructions; the existing battery has not been replaced in over one year.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 June 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 June 2020 Resolved
Each life buoy must be marked with Type II reflective material approved IAW 164.018; the existing ring buoy is new and is not properly marked with reflective material.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 June 2020
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 June 2020 Resolved
A vessel must carry a first aid kit, approval number 160.041, or a kit with an equivalent contents; the existing kit is not an approved type.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 June 2020
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 June 2020 Resolved
The installation of each portable fire extinguisher must be to the satisfaction of the OCMI; the extinguisher for the operating station has been renewed and is not properly mounted.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 June 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 June 2019 Resolved
Fuel hose does not indicate specifications; provide proof that the fuel hose is USCG Type A appproved.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 August 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 June 2019 Resolved
The fuel system is not equipped with a strainer, install a fuel strainer IAW 46 CFR 182.455 (b) (6).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 June 2019 Resolved
New wire runs under the operating station are not protected with overcurrent device; install overcurrent protection where needed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 June 2019 Resolved
There too many wire connections on the battery terminal; install a bus bar for the ground wire connections.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 August 2019
Personnel › Certificates/Documents/Licenses › License, Master
Issued 22 May 2018 Resolved
Provide licensed captain and crew for drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 June 2018
Resolution: A properly licensed Capt was onboard and conducted drills.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 22 May 2018 Resolved
Provide documentation that crew is enrolled in drug consortium and has conducted pre-employment testing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 June 2018
Resolution: Documentation of pre-employment testing provided.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 22 May 2018 Resolved
Provide in date alcohol test strips.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 June 2018
Resolution: Test strips have been ordered and POC stated they will be placed onboard.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 22 May 2018 Resolved
Provide proof of overcurrent protection for paddle-wheel winch. If none, install in line fuse as close to battery as possible.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 June 2018
Resolution: POC stated that the builder provided info that the winch has overcurrent incorporated into the unit.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 February 2017 Resolved
COMPLETE A NEW TO ZONE INSPECTION AND THE ATTACHED WORKLIST DATED 10 FEB 2017 TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO THE CARRIAGE OF PASSENGERS.
Action required: 705 - Other - as specified
Due 10 March 2017
Resolved 22 May 2018
Resolution: Outstanding Def from previous unit.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.