Records from 2017 to 2024. Most recent: inspection, 13 December 2024.
Inspection history · 15
13 December 2024
Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8047067
13 December 2024
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8064229
12 December 2024
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8043223
4 December 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8043125
4 December 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8043391
7 June 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7708008
10 May 2022
PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7447373
8 May 2020
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6947262
18 July 2019
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6753957
19 June 2019
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6718687
23 February 2018
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6360286
22 March 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6110257
13 March 2017
In-Service Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6103947
13 March 2017
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6105260
23 February 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6093104
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 19 June 2019
Resolved
14104: OIL FILTERING EQUIPMENT SHALL BE PROVIDED WITH ARRANGEMENTS TO ENSURE THAT ANY DISCHARGE OF OIL MIXTURES IS AUTOMATICALLY STOPPED WHEN THE OIL CONTENT OF THE EFFLUENT EXCEEDS 15PPM. OCM F/W FLUSH, SAMPLE LINE, AND DRAIN LINE ARE DESIGNED IN A WAY THAT ENABLES BYPASS OF OCM DURING NORMAL OPERATIONS, WHEN ALL 3 VALVES ARE CLOSED AND A F/W SAMPLE IS TRAPPED IN OCM. VALVES ARE INSTALLED AS DEPICTED ON SCHEMATICS AND ORIGINAL INSTALLATION.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2019
Resolved 25 June 2019
Resolution: Recieved class report.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 23 February 2018
Resolved
74SOLAS (14) II-2/5.2.1 FSS CODE 5.2.1.2.1- Machinery spaces of catagory A containing internal combustion machinery shall be provided with one of the fixed fire-extinguishing systems in paragraph 4.1. The piping for the distibution of the medium is obtained. Three pilot lines in the CO2 room are broken and not capable of sequentially releasing the medium into the main engine room. 17ac.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 February 2018
Resolution: Repairs were made to four sections of the CO2 system activation loops that were found damaged and broken near the fitting inlet. The broken pilot lines were renewed and loose racks were tightened to the satisfaction of vessel's classification society.
Fire Fighting › Portable Foam Applicators › General
Issued 23 February 2018
Resolved
74SOLAS (14) II-2/14.2.1.2- Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Portable extinguishers which have been discharged shall be immediately recharged or replaced with and equivalent unit. AFF portable foam applicator in main engine room was not in working order due to puncture and leakage in aff tank. 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 February 2018
Resolution: AFF portable foam applicator tank in main engine room was renewed with a 20 liter 3% Sthamex Foam. AFF application system was reported acceptable by vessel's classificatin society.
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 23 February 2018
Resolved
74SOLAS (14)IX/5 ISM CODE 10.1- The Safety Management Syetem shall be maintained with the provisions of the international safety management code. The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the releveant rules and regulations and with any additional requirements which may be established by the company. The maintainace requirements outlined in the SMS for the fixed fire fighting system does not meet the international standard or manufacturer specifications. Additionaly the SMS and PMS schedual contridict eatch other and do not list the specific requirements of a proper inspection maintance. 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 February 2018
Resolution: Vessel's SMS manual and PMS schedulas have been harmonized and updated to reflect current inspecitons and maintenance of fire extinguishing appliances to meet the internationl standard guidlines listed in MSC.1/Cir.1318 & 1432.
Engineering › Diesel Engine (propulsion-direct drive) › Distributor (fuel injection)
Issued 13 March 2017
Resolved
Electronic/electrical control unit for main diesel engine is non operational.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 March 2017
Resolution: Vessel provided tech and class report that all items were repaired and tested operational.