MAURY USCG vessel records
← All vessels

PAPA GEORGE

PAPA GEORGE is a 2017 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2017, most recently in February 2026, along with 6 deficiencies.

Records from 2017 to 2026. Most recent: inspection, 23 February 2026.

Built
2017
Last inspected
23 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 February 2026
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2017–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK2280
1429695
Flag
UNITED STATES
Maury page id
psix-1429695

Documentation record

Registered dimensions (L × B × D)45.0 ft × 14.0 ft × 3.5 ft
Registered tonnagegross 11 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCORINTHIAN CATAMARANS LLC · Tarpon Springs, FL, UNITED STATES · built 2017
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portBEAUFORT, NC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 16

23 February 2026 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8314636
5 January 2026 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8291235
27 February 2025 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8081374
12 February 2024 Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7864148
7 March 2023 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7646402
15 March 2022 COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7406988
27 January 2022 Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7381593
17 February 2021 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7141793
1 February 2021 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7122943
4 March 2020 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6920740
30 January 2020 Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6902699
17 January 2020 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6891674
26 March 2019 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6647167
6 March 2018 Drydock Exam · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6368812
21 March 2017 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6108594
4 January 2017 Construction Oversight · Internal Structural Exam · Deadweight Survey · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6066546

Deficiency record · 6

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 January 2020 Resolved
Steering hydrulic hoses cracked not leaking. replace with new
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2020
Resolution: Objective evidence received with proof of new hoses installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 January 2020 Resolved
Fuel shut off valve not closing all the way
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2020
Resolution: New valve installed
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 January 2020 Resolved
Rusted fire ext. and servicing is with in a month.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2020
Resolution: Servicing complete and painted fire ext.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 January 2020 Resolved
Battery needs to be cleaned and tighten connections.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2020
Resolution: Battery cleaned and tightened.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 30 March 2018 Resolved
FCC Marine Radio operators permit not issued to CAPT.
Action required: 705 - Other - as specified
Due 29 April 2018
Resolved 10 April 2018
Resolution: Provided via e-mail.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 30 March 2018 Resolved
Expired FCC Station Lic. and Cert.
Action required: 705 - Other - as specified
Due 29 April 2018
Resolved 15 May 2018
Resolution: Vessel rep provided FCC station Lic, and Cert.

Ownership record