KAPENA BOB PURDY

Built
2019
Last inspected
11 July 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 11 July 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2017–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9816880
WDK6288
1430927
Flag
UNITED STATES
Maury page id
psix-1430927

Documentation record

Registered dimensions (L × B × D)112.6 ft × 34.4 ft × 15.7 ft
Registered tonnagegross 391 / net 265
ITC dimensions (L × B × D)112.6 ft × 34.4 ft × 15.7 ft
ITC tonnagegross 455 / net 136
BuilderCONRAD SHIPYARD LLC · AMELIA, LA, UNITED STATES · built 2019
Hull materialSteel
PropulsionDiesel Direct
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portKAHULUI MAUI, HI
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 5 May 2026 · expires 30 June 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it315 - Dead Weight, Metric Ton
455 - Convention (Subpart B), Gross Ton
391 - Regulatory (Subpart C or D), Gross Ton
136 - Convention (Subpart B), Net Ton
265 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 21 inspections, each with its date, unit and type; 19 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 21

11 July 2025 COI Inspection · Vessel Attendance
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8172315
9 June 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8159025
26 November 2024 Exemption · Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8101474
6 September 2024 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8039994
17 June 2024 In-Service Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8008841
11 September 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7786226
16 September 2022 Periodic Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7558459
18 June 2022 Examination of Repairs · Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7481134
25 May 2022 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7460740
24 May 2021 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7205898
10 January 2021 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7126806
8 July 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6998923
30 January 2020 Administrative Inspection · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6894280
30 December 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6880702
6 November 2019 Administrative Inspection · Examination of Repairs · Deficiency Check · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6850854
30 August 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6799329
30 August 2019 Administrative Inspection · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6808011
29 August 2019 Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6798516
15 August 2019 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6784935
9 August 2019 Administrative Inspection · Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6781455
23 August 2017 MTSA Verification · Administrative Inspection · Construction Oversight · Initial Certification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6249501

Deficiency record · 19

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 June 2024 Resolved
Certificates of inspection will be issued for a period of 5 years. Application may be made by the master, owner, or agent for inspection and issuance of a new certificate of inspection at any time during the period of validity of the current certificate. Vessel is currently in dry dock. Vessel's COI is expired. Needs to submit an Application of Inspection and conduct Inspection prior to conducting commercial operations.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 24 June 2024
Resolved 7 August 2025
Resolution: Conducted COI Renewal.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 11 September 2023 Resolved
It is the intent of this subpart to provide such markings as are necessary for the guidance of the person on board in case of an emergency. Label with a placard or stencil letters of a contrasting color the four red valve handles on the aft accommodations weather deck bulkhead that isolates the engine room supply and exhaust ventilation trunks in the event of down flooding to the satisfaction of the attending MI. 46 CFR 97.37-3(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2023
Resolved 30 November 2023
Resolution: Accepted by ABS surveyor, report uploaded; all sat.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 11 September 2023 Resolved
All other openings to a protected space must be capable of being closed. Doors, shutters, or dampers must be installed for openings in the lower portion of the space. The stbd machinery space horizontal supply and stbd vertical dampener louvers failed to close upon activation of the machinery space ventilation emergency stop switch. Additionally, the port machinery space exhaust vertical damper louvers failed to fully close. Repair and prove proper operation in the presence of the the attending MI. 46 CFR 95.16-30(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2023
Resolved 30 November 2023
Resolution: Accepted by ABS surveyor, report uploaded; all sat.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 6 October 2022 Resolved
At each inspection for certification and periodic inspection, the inspector will check fire-extinguishing equipment with the following tests and inspections: Halon 1301 and halocarbon, Test time delays, alarms, and ventilation shutdowns with carbon dioxide, nitrogen, or other non-flammable gas as stated in the systems manufacturer's instruction manual. The vessel was not prepared to demonstrate testing of the FM200 halocarbon system's time delay, alarms and ventilation shutdowns. The attending Marine Inspector verified that the FM200 fixed fire extinguishing system had been serviced with in the past year. Demonstrate that the FM200 Halocarbon system's time delay, alarms, and ventilation shutdowns operate as designed and in accordance with 46 CFR 95.16. Testing shall be to the satisfaction of the attending Marine Inspector. 46 CFR 91.25-20 (a) (2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2022
Resolved 27 October 2022
Resolution: Witnessed satisfactory testing; all sat.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 6 October 2022 Resolved
At each inspection for certification and periodic inspection, the inspector will check fire-extinguishing equipment with the following tests and inspections: The fire main system must be operated and the pressure checked at the most remote and highest outlets. All firehose must be subjected to a test pressure equivalent to the maximum pressure to which they may be subjected in service, but not less than 100 p.s.i. The vessel was not prepared to subject all firehose to a minimum 100 p.s.i. pressure test. Conduct the firehose pressure test detailed above to the satisfaction of the attending Marine Inspector. 46 CFR 91.25-20 (a) (4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2022
Resolved 27 October 2022
Resolution: Witnessed satisfactory hydrostatic pressure test; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 June 2022 Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must:(1) Be maintained to ensure proper operation;(2) Be suitable for route and service; and (3) Have suitable propulsion controls to provide the operator full control at each operating station. The vessel's port engine had a low lube pressure arlarm sound during transit from Oahu to Hawaii. The vessel shall transit to Oahu to conduct permanent repairs to the port main diesel engine for compliance with 46 CFR part 143.205(c). In addition the vessel shall have an assist vessel aid them in and out of ports. 46 CFR part 143.205(c)
Condition: Design Flaw
Action required: 15 - Rectify deficiencies by next port
Resolved 20 June 2022
Resolution: Port main engine repaired.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 24 May 2021 Resolved
Electric installations on vessels must ensure protection of passengers, crew, other persons, and the vessel from electrical hazards. Remove or replace daisy chain of extension cords found in mate's stateroom with single cord. 46CFR111.01-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 6 August 2021
Resolution: Received pictures of daisy chain removed from stateroom.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 May 2021 Resolved
Remote bilge level sensors, where provided, must be located to detect flooding at an early stage and to provide redundant coverage. Vessel's port aft engine room bilge alarm inoperable. 46CFR62.35-10(c)
Action required: 10 - Deficiency Rectified
Due 24 May 2021
Resolved 24 May 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 May 2021 Resolved
Batteries must be constructed to take into account the environmental conditions of a marine installation, including temperature, vibration, and shock. Non-permanent type connectors found on batteries atop pilot house. 46CFR111.15-2
Action required: 10 - Deficiency Rectified
Due 24 May 2021
Resolved 24 May 2021
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 8 July 2020 Resolved
Natural ventilation provided for a space protected by a clean agent system must be capable of being easily and effectively closed. Ventilation closures to the machinery space are secured open using nuts and bolts that would require tools to close. 46 CFR 95.16-30(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2020
Resolved 3 August 2020
Resolution: Vessel had replaced nuts and bolts arrangement for manual engine room ventilation closures and installed triangular eye bolts capable of being secured and opened by hand.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 8 July 2020 Resolved
Each US ship of 400 gross tons and above that engages in international voyages must have on board a valid International Oil Pollution Prevention (IOPP) Certificate. Vessel has IOPP certificate for international service but was unable to demonstrate proper operation of the oily water separator system due to unfamiliarity. System was tagged out upon arrival to vessel. Vessel restricted from international service until OWS operation is verified. 33 CFR 151.19 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 3 August 2020
Resolution: Witnessed proper operational test of OWS in accordance with owners manual.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 July 2020 Resolved
There shall be at least two means of escape from all general areas where the crew may be quartered or normally employed. Vessel had 01 escape hatch seized shut due to lack of maintenance in a machinery space, and 03 other hatches very difficult to operate due to lack of maintenance. Provide maintenance plan to ensure proper operation of emergency escape hatches. 46 CFR 92.10-5
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 3 August 2020
Resolution: Vessel provided updated maintenance cards reqiring weekly operation and evaluation of emergency escape hatches
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 6 November 2019 Resolved
When automated systems are provided to replace specific personnel in the control and observation of the engineering plant and spaces, or reduce overall crew requirements, the arrangements must make sure that under all sailing conditions, including maneuvering, the safety of the vessel is equal to that of the same vessel with the entire plant under fully attended direct manual supervision. The chief engineer reported the starboard main engine shut down when the automated system alarmed for a high main bearing temperature on bearings 1 through 5. The active alarm panel currently states that the starboard main engine bearings 1-5 temperature sensors contain a hardware fault. The starboard main engine main bearing temperature sensors 1-5 are reading temperature ranges between 174 degrees F and 182 degrees F, providing an alarm for high temperature. Provide a technician's report attesting to the proper function of the starboard main engine bearings 1-5 temperature sensors prior to operating with reduced manning per the valid COI. The vessel may sail in a fully manned condition, per the valid COI, with appropriately credentialed engine room watch standers and a 24 hour attended machinery space.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 November 2019
Resolved 15 November 2019
Resolution: A GE technician replaced the oil mist alarm wire harness in kind. The alarm was tested to the PSTP standard. The engine was tested satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 November 2019 Resolved
The minimum instrumentation alarms and safety controls required for specific types of systems are listed in table 62.35-50. Main propulsion diesel engines must comply with the alarms listed in ABS Rules part 4-9-4 tables 7-A and 8. ABS rules state that oil mist in crankcase, high mist concentration, high bearing temperature, or alternative arrangements must provide an alarm and shutdown the main diesel engine. The starboard main engine bearing temperatures for bearings 1-5 are in an alarm state based on the temperature readings received from the temperature sensors and associated equipment. The starboard main engine cannot operate in this condition. Provide a technician's report attesting to the proper operation of the starboard main engine prior to any operation requiring the use of the starboard main engine. Contact the USCG marine inspector to attend the vessel for attendance to verify the starboard main engine operation prior to use.
Action required: 705 - Other - as specified
Due 6 December 2019
Resolved 15 November 2019
Resolution: A GE technician replaced the oil mist alarm wire harness in kind. The alarm was tested to the PSTP standard. The engine was tested satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 August 2019 Resolved
No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge of the Officer in Charge, Marine Inspection. Drawings of alterations shall be approved before work is started by the Officer in Charge, Marine Inspection. Submit repair proposal to address area of damage on the port stern.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2019
Resolved 11 December 2019
Resolution: Received repair proposal attached in documents. Repair is temporary and will be addressed at next drydock. Approved by USCG and ABS. Conducted visual exam of final welds on additional stiffener. Special note added to monitor and conduct final rprs in DDX.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 August 2019 Resolved
A vessel equipped with fixed pitch or controllable pitch propellers must have on the navigating bridge and at the engineroom control station a propeller speed and direction indicator or a propeller speed and pitch indicator for each shaft. Vessel was not constructed with shaft speed and thrust indicators IAW 46 CFR 113.37.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2019
Resolved 30 December 2019
Resolution: Witnessed satisfactory testing of both port and stbd shaft tachometers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 August 2019 Resolved
Port engine turbo failed. Repair in accordance with 46 CFR 90.20.1. Permission granted for one time transit to Oahu to facilitate repairs. Repairs to be made prior to towing operations. Contact Sector Honolulu Inspections for repair oversight in accordance with 46 CFR 91.45.1.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2019
Resolution: Recieved confirmation from Sector Honolulu inspections that deficiency has been cleared.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 23 August 2017 Resolved
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2019
Resolved 9 September 2019
Resolution: Verified vessel has a valid COD.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 August 2017 Resolved
Vessel is required a propeller speed and direction indicator for each shaft
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 17 June 2019
Resolved 9 August 2019
Resolution: Sector Honolulu issued an updated CG-835V requirement for the same deficiency on 9AUG2019 Misle Activity number 6781455.