GAS LEO is a 2016 tank ship. The Coast Guard has recorded 13 inspections since 2017, most recently in April 2026, along with 7 deficiencies and 1 operational control.
Records from 2017 to 2026. Most recent: inspection, 2 April 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it46789 - Convention (Subpart B), Gross Ton 53748 - Dead Weight, Metric Ton 18825 - Convention (Subpart B), Net Ton 19666 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 13
2 April 2026Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8341038
19 April 2025COC-GAS Renew · PSC B · Administrative Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8113486
12 December 2024Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8046707
21 November 2024Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8038121
20 March 2024Administrative Inspection · PSC B · COC-GAS Annual
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 August 2021Resolved
Electrical installations should be such to minimize the risk of fire and explosion from flammable products. Electric cable casing repairs made on Tank #4 and Tank #3 must be made in accordance with the International Electric Code (IEC)
SOLAS 76/78(14) VII/13.1 IGC 10.1.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 January 2022
Resolution: Received RO Report 2125817. All sat. Cleared def.
Electrical › Electric Supply System (service) › Cable
Issued 17 April 2018Resolved
Electrical installation should be such as to minimize the risk of fire and explosion from flammable products. While conducting a deck walk, PSCOs discovered the electrical power cable going into the alarm outside the airlock is missing the proper approved fitting. The area where the cable goes into the alarm fixture has been filled with silicone. 74SOLAS(14) VII/13.1 IGC CODE 10.1.2 CODE 30ABC
Condition: Improper Installation
Action required: 30 - Ship detained
Due 17 April 2018
Resolved 20 April 2018
Resolution: Received an email with pictures from the ship's master showing the proper fitting and its approval for the explosion-proof fixture it was attached to. The master's email has been attached to this activity.
Where electrical equipment is installed in gas-dangerous spaces or zones, it should be to the satisfaction of the administration and approved by the relevant authorities recognized by the administration for operation in the flammable atmosphere concerned. While conducting the deck walk, PSCOs observed salt and/or standing water in almost every light fixture on deck. These lights include all tank domes and all lights around the compressor room. PSCOs also noted that silicone had been added to all light fixtures on deck. Standing water/salt provides objective evidence that the integrity of the enclosure has been compromised. 74SOLAS(14) VII/13.1 IGC 93/ 10.1.5 30ABC
Condition: Improper Installation
Action required: 30 - Ship detained
Due 17 April 2018
Resolved 20 April 2018
Resolution: Received an email containing pictures and a statement from the ship's master attesting and showing the new lights installed on deck. The master also provided documentation for the approval of the new fixtures. The master's email has been attached.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 17 April 2018Resolved
A permanently installed system of gas detection with audible and visual alarm should be provided for enclosed spaces in the cargo area where vapor may accumulate including hold spaces. Vessel could not demonstrate satisfactory operation of the fixed gas detection sample system for the cargo hold spaces. The crew used a span gas containing 50% LEL butane, but could not produce a reading on the fixed sample system for the hold spaces. The LEL reading on the fixed gas detection system for the hold spaces never went above 0% LEL. 74SOLAS(14) VII/13.1 IGC 93/ 13.6.7.5 30ABC
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 17 April 2018
Resolved 18 April 2018
Resolution: SEC HOU-GAL PSC Branch attended vessel and witnessed proper operation of fixed gas detection system.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 17 April 2018Resolved
The safety management system should ensure compliance with mandatory rules and regulation and that applicable codes, guidelines and standards recommend by the organization, administrations, classification societies and maritime industry organization are taken into account. PSCOs discovered objective evidence that the vessel has failed to fully implement the safety management system. PSCOs reviewed the ship/shore safety checklist dated 16APR2018 (Document #D-04) and monthly report of fixed gas analyzer maintenance and calibration record (Document #CCR-03). Both documents state that the fixed gas detection system had been tested satisfactory on 16APR2018 and 13APR2018 respectively. The crew could not prove proper operation of the system during PSC exam. PSCOs reviewed the critical equipment checklist/record for LPG/Ethylene carriers (Document #S-40.1). The crew stated the last monthly check of the deck lighting (Item #42) was 29MAR2018 without issue. PSCOs found salt and/or water in almost every deck light. 74SOLAS(14) IX/3.1 ISM CODE 1.2.3.1 & ISM CODE 10.3 30ABC
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 17 April 2018
Resolved 20 April 2018
Resolution: Received a written statement from the ship's master attesting to the findings of his internal ISM investigation. The master included his corrective actions in his statement. A copy of the written statement has been attached to this activity.
The changing of set pressure should be carried out under the supervision of the Master. Changes in set pressures should be recorded in the ship’s log stating the set pressure. The vessel’s crew did not document the corresponding “harbor” (.45barg) relief valve pressure settings in the ship’s log upon the change from the “at sea” (.25barg) setting on 16APR2018. 74 SOLAS (14) VII/13.1; IGC 93/ 8.2.7
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 17 April 2018
Resolved 17 April 2018
Resolution: CG PSCOs witnessed proper installation while onboard.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 17 April 2018Resolved
The gas detection equipment should be capable of sampling and analyzing for each sampling head locating sequentially at intervals not exceeding 30 minutes. The gas detection systems both powered down following a test of the ESD. The vessel’s crew were unable to restart the gas detection systems. PSCOs and the crew could not recreate the gas detection trip/shutdown from an ESD. 74SOLAS(14) VII/13.1 IGC 93/ 13.6.8
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 April 2018
Resolved 17 April 2018
Resolution: CG PSCOs were unable to recreate gas detection trip/shutdown from ESD while onboard.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.