GAS LEO is a 2016 tank ship. The Coast Guard has recorded 13 inspections since 2017, most recently in April 2026, along with 7 deficiencies and 1 operational control.

Records from 2017 to 2026. Most recent: inspection, 2 April 2026.

Built
2016
Last inspected
2 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 April 2026
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2017–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9735282
1430974
Flag
HONG KONG
Maury page id
psix-1430974

Documentation record

Tonnage as PSIX records it46789 - Convention (Subpart B), Gross Ton
53748 - Dead Weight, Metric Ton
18825 - Convention (Subpart B), Net Ton
19666 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 13

2 April 2026 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8341038
19 April 2025 COC-GAS Renew · PSC B · Administrative Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8113486
12 December 2024 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8046707
21 November 2024 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8038121
20 March 2024 Administrative Inspection · PSC B · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7882064
20 March 2023 PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7650088
6 January 2022 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7376556
20 August 2021 PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7277748
10 June 2019 ISPS II Exam · Ballast Water Examination · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6704709
18 April 2018 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6489415
17 April 2018 Deficiency Check · Ballast Water Examination · COC-GAS Annual · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6391879
17 April 2018 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6489385
1 March 2017 Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6096616

Deficiency record · 7

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 August 2021 Resolved
Electrical installations should be such to minimize the risk of fire and explosion from flammable products. Electric cable casing repairs made on Tank #4 and Tank #3 must be made in accordance with the International Electric Code (IEC) SOLAS 76/78(14) VII/13.1 IGC 10.1.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 January 2022
Resolution: Received RO Report 2125817. All sat. Cleared def.
Electrical › Electric Supply System (service) › Cable
Issued 17 April 2018 Resolved
Electrical installation should be such as to minimize the risk of fire and explosion from flammable products. While conducting a deck walk, PSCOs discovered the electrical power cable going into the alarm outside the airlock is missing the proper approved fitting. The area where the cable goes into the alarm fixture has been filled with silicone. 74SOLAS(14) VII/13.1 IGC CODE 10.1.2 CODE 30ABC
Condition: Improper Installation
Action required: 30 - Ship detained
Due 17 April 2018
Resolved 20 April 2018
Resolution: Received an email with pictures from the ship's master showing the proper fitting and its approval for the explosion-proof fixture it was attached to. The master's email has been attached to this activity.
Electrical › Lighting (service) › Lighting Fixture
Issued 17 April 2018 Resolved
Where electrical equipment is installed in gas-dangerous spaces or zones, it should be to the satisfaction of the administration and approved by the relevant authorities recognized by the administration for operation in the flammable atmosphere concerned. While conducting the deck walk, PSCOs observed salt and/or standing water in almost every light fixture on deck. These lights include all tank domes and all lights around the compressor room. PSCOs also noted that silicone had been added to all light fixtures on deck. Standing water/salt provides objective evidence that the integrity of the enclosure has been compromised. 74SOLAS(14) VII/13.1 IGC 93/ 10.1.5 30ABC
Condition: Improper Installation
Action required: 30 - Ship detained
Due 17 April 2018
Resolved 20 April 2018
Resolution: Received an email containing pictures and a statement from the ship's master attesting and showing the new lights installed on deck. The master also provided documentation for the approval of the new fixtures. The master's email has been attached.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 17 April 2018 Resolved
A permanently installed system of gas detection with audible and visual alarm should be provided for enclosed spaces in the cargo area where vapor may accumulate including hold spaces. Vessel could not demonstrate satisfactory operation of the fixed gas detection sample system for the cargo hold spaces. The crew used a span gas containing 50% LEL butane, but could not produce a reading on the fixed sample system for the hold spaces. The LEL reading on the fixed gas detection system for the hold spaces never went above 0% LEL. 74SOLAS(14) VII/13.1 IGC 93/ 13.6.7.5 30ABC
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 17 April 2018
Resolved 18 April 2018
Resolution: SEC HOU-GAL PSC Branch attended vessel and witnessed proper operation of fixed gas detection system.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 17 April 2018 Resolved
The safety management system should ensure compliance with mandatory rules and regulation and that applicable codes, guidelines and standards recommend by the organization, administrations, classification societies and maritime industry organization are taken into account. PSCOs discovered objective evidence that the vessel has failed to fully implement the safety management system. PSCOs reviewed the ship/shore safety checklist dated 16APR2018 (Document #D-04) and monthly report of fixed gas analyzer maintenance and calibration record (Document #CCR-03). Both documents state that the fixed gas detection system had been tested satisfactory on 16APR2018 and 13APR2018 respectively. The crew could not prove proper operation of the system during PSC exam. PSCOs reviewed the critical equipment checklist/record for LPG/Ethylene carriers (Document #S-40.1). The crew stated the last monthly check of the deck lighting (Item #42) was 29MAR2018 without issue. PSCOs found salt and/or water in almost every deck light. 74SOLAS(14) IX/3.1 ISM CODE 1.2.3.1 & ISM CODE 10.3 30ABC
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 17 April 2018
Resolved 20 April 2018
Resolution: Received a written statement from the ship's master attesting to the findings of his internal ISM investigation. The master included his corrective actions in his statement. A copy of the written statement has been attached to this activity.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pressure/Vacuum Relief Valve
Issued 17 April 2018 Resolved
The changing of set pressure should be carried out under the supervision of the Master. Changes in set pressures should be recorded in the ship’s log stating the set pressure. The vessel’s crew did not document the corresponding “harbor” (.45barg) relief valve pressure settings in the ship’s log upon the change from the “at sea” (.25barg) setting on 16APR2018. 74 SOLAS (14) VII/13.1; IGC 93/ 8.2.7
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 17 April 2018
Resolved 17 April 2018
Resolution: CG PSCOs witnessed proper installation while onboard.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 17 April 2018 Resolved
The gas detection equipment should be capable of sampling and analyzing for each sampling head locating sequentially at intervals not exceeding 30 minutes. The gas detection systems both powered down following a test of the ESD. The vessel’s crew were unable to restart the gas detection systems. PSCOs and the crew could not recreate the gas detection trip/shutdown from an ESD. 74SOLAS(14) VII/13.1 IGC 93/ 13.6.8
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 April 2018
Resolved 17 April 2018
Resolution: CG PSCOs were unable to recreate gas detection trip/shutdown from ESD while onboard.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.