SAND TOPIC is a 2017 freight ship. The Coast Guard has recorded 10 inspections since 2017, most recently in March 2025, along with 1 deficiency and 1 operational control.
Records from 2017 to 2025. Most recent: inspection, 27 March 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it60155 - Dead Weight, Metric Ton 71552 - Displacement, Metric Ton 34905 - Convention (Subpart B), Gross Ton 19977 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
Inspection history · 10
27 March 2025PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8094374
17 March 2025Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8096371
19 January 2023PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7623655
7 March 2022Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7406969
7 March 2022Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7407386
4 March 2021Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7150523
2 March 2021PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7142286
18 February 2021Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7142459
30 January 2019ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6614716
26 March 2017ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6100458
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 March 2021Resolved
Maintenance, testing and inspections shall be carried out baed on the guidelines developed by the organization and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. PSCO noted the required annual servicing of CO2 fixed supression system has not been carried out in accordance with MSC.1/Circ.1432.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2021
Resolution: Satisfactorily reviewed servicing report for annual fire servicing from authorized service provider SURVITEC and accompanying Lloyd's Register Class Report attesting to acceptance of servicing. For more details see Activity #7150523