Records from 2017 to 2025. Most recent: inspection, 17 March 2025.
Inspection history · 9
17 March 2025
COC-TVE Renew · PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8087240
8 May 2021
PSC B · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7191773
19 March 2020
COC-TVE Annual · ISPS Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6914496
4 March 2020
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6921226
27 January 2019
COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6615616
5 March 2018
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6366007
28 February 2018
ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6350305
10 April 2017
ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6121379
6 February 2017
COC-TVE Renew · ISPS III Exam
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6085795
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 17 March 2025
No resolution recorded
The company should establish procedures to ensure that the ship is maintained in conformity wiht the provisions of the relevant rules and regulationsand with any additional requirements which may be established by the company. The crew failed to follow procedures related to the bilge suction valves post maintenance by ensuring they were open in case of flooding. An internal audit of procedures is recommended.
74 SOLAS (20) IX/3.1
ISM CODE 10.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2025 — due date passed with no resolution recorded
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 17 March 2025
Resolved
An efficient bilge pumping system shall be provided, capable of pumping from and draining any watertight compartment...under all practical conditions. The bilge suction valves in the pump room as well as both in the forward bosun locker were all closed. Contrary to their procedures requiring them to be oepn. Crew opened all valves.
74 SOLAS (20) II-1/35-1.2.1
Action required: 10 - Deficiency Rectified
Due 17 March 2025
Resolved 21 March 2025
Resolution: opened valves
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 17 March 2025
Resolved
Oil fuel pipes, which, if damaged, would allow oil to escape from a storage, settling, or daily service tank having a capacity of 500L and above situated above the doubnle bottom. Shal be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire occuring in the space which such tanks are situated. Quick closing vavle for the emergency generator fuel tank not capable of fully closing the tank valve from outside the space.
74 SOLAS (20) II-2/4.2.2.3.4
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2025
Resolved 17 March 2025
Resolution: Crew rectified on the spot.
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 8 May 2021
Resolved
FOLLOWING INSTALLATION, THE MASTER, OWNER, OPERATOR, AGENT, OR PERSON IN CHARGE OF THE VESSEL MUST PROPERLY MAINTAIN THE BWMS IN ACCORDANCE WITH ALL MANUFACTURER SPECIFICATIONS. VESSEL SHALL NOT DISCHARGE BALLAST WATER INTO U.S. WATERS.
33CFR151.2025(a)(1)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 June 2021