OWL 5 is a 2009 tank ship. The Coast Guard has recorded 15 inspections since 2017, most recently in August 2025, along with 39 deficiencies and 1 operational control, 1 with no removal date recorded.
Records from 2017 to 2025. Most recent: inspection, 28 August 2025.
- Built
- 2009
- Last inspected
- 28 August 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 39 recorded · 0 without a recorded resolution
- Controls
- 1 with no removal date recorded
Identity
9439357 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7SE2
1431862
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1431862
Inspections, by type
…with no type recorded2
Years with a record
6 calendar years (2017–2025)
The 15 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it8539 - Convention (Subpart B), Gross Ton
4117 - Convention (Subpart B), Net Ton
17472 - Displacement, Metric Ton
13062 - Dead Weight, Metric Ton
4117 - Convention (Subpart B), Net Ton
17472 - Displacement, Metric Ton
13062 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 15
28 August 2025
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8219880
26 August 2025
Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8218228
15 July 2025
Type not recorded
No type recorded · Station Alexandria Bay · USCG Great Lakes District (CGD-GL) · Activity 8186754
4 July 2025
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8172204
28 January 2025
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8071128
2 August 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7972917
20 May 2024
COC-CHEM & TVE Renew · In-Service Inspection · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7915528
10 May 2023
Administrative Inspection · Deficiency Check · PSC B · COC-CHEM & TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7685106
17 May 2022
Administrative Inspection · COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7450391
9 July 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6743176
26 April 2019
ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6664628
25 April 2019
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6670451
14 April 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6661954
1 August 2017
Administrative Inspection · ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6229907
27 July 2017
Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6220292
Deficiency record · 39
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 10 May 2023
Resolved
THE INERT GAS SYSTEM SHALL BE CABABLE OF INERTING EMPTY TANKS AND MAINTAINING THE ATMOSHOPHERE IN CARGO TANKS WITH THE REQUIRED OXYGEN CONTENT. PSCO OBSERVED A FUEL OIL LOW PRESSURE ALARM ON INERT GAS SYSTEM PANEL. CREW COULD NOT PRODUCE THE INERT GAS SYSTEM TO PROVIDE A OXYGEN CONTENT LESS THAN 5%. VESSEL IS CURRENTLY CARRYING CARGO THAT DOES NOT REQUIRE INERTING.
74 SOLAS (20) II-2/4.5.5.3.1.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 10 May 2023
Resolved
INSTRUMENTATION SHALL BE FITTED FOR CONTINOUSLY INDICATING AND PERMANENTLY RECORDING, WHEN INERT GAS IS BEING SUPPLIED: THE OXYGEN CONTENT OF THE INERT GAS. PSCO OBSERVED THE CREW UNABLE TO ACCURATELY CALIBRATE THE OXYGEN ANALYZER FOR THE INERT GAS GENERATOR.
74 SOLAS (20) II-2/5.5.4.1
FSS CODE 15.2.2.4.2.2
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 May 2023
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROCISION OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. REFRACTORY BRICK ON INCINERATOR FOUND WASTED.
74 SOLAS (20) I/11A
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 May 2023
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROCISION OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS…PIPING LEADING INTO SOOT COLLECTION TANK WAS WRAPPED WITH PLASTIC BAGS AND RAGS.
74 SOLAS (20) I/11A
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 May 2023
Resolved
MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. MULTIPLE OIL-SOAKED RAGS AND EXCESSIVE ACCUMULATION OF OIL FOUND AT VARIOUS LOCATIONS ON THE MAIN ENGINE.
74 SOLAS (20) II-2/4.1.1
Deck/Cargo › Vapor Control Systems › Manual Isolation Valve
Issued 1 August 2017
Resolved
2550-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO noted valve handles throughout the cargo deck were wasted, missing and inoperable. 74SOLAS(14)I/11
Deck/Cargo › Cargo Heating › General
Issued 1 August 2017
Resolved
2550-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO noted that the entire steam piping system to include valves and insulation was severely wasted. 74SOLAS(14)I/11
Deck/Cargo › Inert Gas System › Gas Regulating Valve
Issued 1 August 2017
Resolved
1899-A gas regulating valve shall be fitted in the inert gas main. This valve shall be automatically controlled to close. PSCO noted that the valve was only able to be manually operated. 74SOLAS(14)II-2/5.5.1.1 FSS Code 15.2.3.1.2.1
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 1 August 2017
Resolved
2550-In addition to fire protection systems and appliances listed in paragraph 2.2.3, tankers shall have a maintenance plan for inert gas systems, deck foam systems and flammable gas detector PSCO noted large portions of the maintenance plans were not being carried out properly. 74SOLAS(14)II-2/14.4
Electrical › Lighting (emergency) › Lighting Fixture
Issued 1 August 2017
Resolved
2550-In tankers, electrical equipment, cables and wiring shall not be installed in hazardous locations unless it conforms with standards not inferior to those acceptable to the organization. PSCO noted that deck lighting throughout the cargo area was in disrepair, lighting fixtures were wasted and falling from mounts, and lights were not properly grounded. 74SOLAS(14)II-1/45.11
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 August 2017
Resolved
0650-In tankers, electrical equipment, cables and wiring shall not be installed in hazardous locations unless it conforms with standards not inferior to those acceptable to the organization. PSCO noted that the life-buoy self igniting lights on the cargo deck were not intrinsically safe. 74SOLAS(14)II-2/45.11
Electrical › Electric Supply System (service) › Cable
Issued 1 August 2017
Resolved
2550-Where cables which are installed in hazardous areas introduce the risk of fire or explosion in the event of an electrical fault in such areas, special precautions against such risks shall be taken to the satisfaction of the administration. PSCO noted that the insulation for the tank high level and overflow alarm cables were wasted and worn. 74SOLAS(14)II-1/45.5.4
Deck/Cargo › Inert Gas System › IGG Isolating Valve
Issued 1 August 2017
Resolved
2550-The inert gas main shall be fitted with branch piping leading to the cargo tank. Branch piping for inert gas shall be fitted with either stop valves or equivalent means of control for isolating each tank. PSCO noted that the 1/S and 1/P IG tank isolating valves and indicators were inoperable due to wastage. 74SOLAS(14)II-2/5.5.1.1 FSS Code 15.2.2.3.2.2
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 1 August 2017
Resolved
2550-Cables and wiring shall be installed and supported in such a manner as to avoid chafing and other damage. PSCO noted numerous missing and wasted cable tray sections throughout the cargo deck. 74SOLAS(14)II-1/45.5.5
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 1 August 2017
Resolved
2550-The venting arrangements shall be so designed and operated as to ensure that neither pressure nor vacuum in cargo shall exceed design parameters. PSCO noted that the 3/P P/V valve would stick and not move freely, and the Stbd Slop P/V valve vacuum side was frozen. 74SOLAS(14)II-2/11.6.1
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 1 August 2017
Resolved
2055-Every crewmember shall be given instructions which shall include but not necessarily be limited to operation and use of ships inflatable life-rafts. PSCO noted that there was no suitable instruction for operations and use of ships inflatable life-rafts. 74SOLAS(14)III/19.4.2
Electrical › Lighting (service) › Switch
Issued 1 August 2017
Resolved
1825-All lighting and power circuits terminating in a bunker or cargo space shall be provided with a multiple pole switch outside the space for disconnecting such circuits. PSCO noted that there was no switch for the lighting in the cargo sample room and the SOPEP locker. 74SOLAS(14)II-1/45.8
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 1 August 2017
Resolved
0999-Accept as permitted by the Administration in exceptional circumstances all metal sheaths and armour of cables should be electrically continuous and shall be earthed. PSCO noted that the electrical trunk running on the cargo deck was not electrically continuous or earthed. 74SOLAS(14)II-1/45.5.1
Deck/Cargo › Holds/Tanks › Portable Gas Measuring Equipment
Issued 1 August 2017
Resolved
1135-Vapor detection instruments may be portable or fixed if a fixed system is installed, at least one portable instrument shall be provided. PSCO noted the vessel had no toxic detection tubes for the portable vapor detection instrument. 74SOLAS(14)VII/10.1 IBC Code 13.2.2
Deck/Cargo › Cargo Condition › Bulk Liquid
Issued 1 August 2017
Resolved
1135-The stowage space shall be cell divided in order to avoid shifting of the bottles at sea, made of a material fully resistant to the different liquids intended to be stowed and equipped with adequate ventilation arrangements. PSCO noted that the samples within the sample locker were not properly stowed. 74SOLAS(14)VII/10.1 IBC Code 16.5.2
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 1 August 2017
Resolved
2550-The venting systems shall be provided with devices to prevent the passage of flame into the cargo tanks. PSCO noted that flame screen on the P/V breaker is covered in paint. 74SOLAS(14)II-2/4.5.3.3
Deck/Cargo › Holds/Tanks › Ullage
Issued 1 August 2017
Resolved
2550-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO noted that the covers for the viewing glass for the tank gauging were frozen. 74SOLAS(14)I/11
Construction/Loadline › Structures › Air Pipe
Issued 1 August 2017
Resolved
2550-Wear air pipes to Ballast and other tanks extend above the freeboard or superstructure deck, the exposed parts of the pipes shall be of substantial construction. PSCO noted that the sounding tube to the stern WBT had a hole in it. ICLL66/20
Construction/Loadline › Structures › Ventilators
Issued 1 August 2017
Resolved
2550-Accept as provided in paragraph 3 of this regulation, ventilator openings shall be provided with weather tight closing appliances. PSCO noted that vents had wasted and worn gaskets and would not seal properly. ICLL66/19.4
Construction/Loadline › Structures › Superstructure
Issued 1 August 2017
Resolved
1299-Efficient guardrails or bulwarks shall be fitted to all exposed parts of the freeboard and superstructure. PSCO noted that the guardrail on the stern of the ship was severely dented. ICLL66/25.2
Construction/Loadline › Structures › Manhole
Issued 1 August 2017
Resolved
2550-The construction and the means for securing the weather tightness of cargo and other hatchways in position 1 and 2 shall be at least equivalent to the requirements of regulations 15 and 16 of this annex. PSCO noted that the dogs for the tank access to 2/P were frozen, preventing the tank from properly closing. ICLL66/14.1
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 1 August 2017
Resolved
2550-A readout for each remote thermometer required by this section must be at the point where cargo transfer is controlled. PSCO noted that 11 temperature gauges at the cargo manifold were inoperable. 46CFR153.440(b) 74SOLAS(14)VII/10.1 IBC Code 7.1.5
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 1 August 2017
Resolved
2550-Each tankship with a vapor collection system must be fitted with a pressure-sensing device, located as close as practicable to the vessel vapor connection, that measures the pressure in the main vapor collection line. PSCO noted that the pressure guages on the aft port and starboard forward vapor lines at the manifold were not installed. 46CFR39.2013
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 1 August 2017
Resolved
2550-Each cargo piping system must be marked with the designation number of the cargo tank it serves at each hose connection, valve, and blind in the piping system the markings must be in characters at least 5cm high. PSCO noted that cargo piping is not marked. 46CFR153.294
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 August 2017
Resolved
0999-Cylinders must always be secured and when not in use they must be stowed in a rack in an upright position with a valve protection cap in place. PSCO noted that the nitrogen bottles for the IG system were not properly secured. 46CFR147.60
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 27 July 2017
Resolved
2500: The flag ADMIN, or RO at request of flag ADMIN shall periodically verify the proper functioning of the safety management system. Found Numerous discrepancies that indicate a breakdown of the safety management system. COTP recommends flag ADMIN perform ISM audit to include all cargo systems. COC will not be issued prior to rectification. 74SOLAS(14)IX/5 ISM14
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 27 July 2017
Resolved
1730: Oil Tanker 150 GT & above must be equipped w/oil discharge & monitoring systems approved by the flag ADMIN. PSCO noted ODME not fully operational. Technician unable to rectify. MARPOL I/31.1
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 27 July 2017
Resolved
1870: Condition of ship and equipment shall be maintained to conform w/provision of present regulation to ensure ship in all respect remains fit to proceed to sea w/out danger to ship or crew. IGG system doesn't function in Automatic mode. Crew installed temp jumper line to cross connect systems permanently(IG to Gas Free). SOLAS(14) I/11
Deck/Cargo › Holds/Tanks › Tank Pressure Monitoring Device
Issued 27 July 2017
Resolved
0999: Pressure sensors may be fitted to each tank protected by the arrangement required in para 6.1.2, with a monitoring system in the ship's cargo control room. PSCO noted pressure sensor in #4S tank is not operational. 72SOLAS(14) II-2/11.6.3.2
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 27 July 2017
Resolved
0999: The Vapor Collection system must have a mechanism to eliminate liquid condensation to draining of collected liquid at low point. PSCO noted VSSL cannot drain condensate due to wasted valves. 46CFR39.2001
Construction/Loadline › Penetrations › Gasket
Issued 27 July 2017
Resolved
0999: Condition of ship and equipment shall be maintained to conform w/provision of present regulation to ensure ship in all respect remains fit to proceed to sea w/out danger to ship or crew. PSCO noted ballast tank pressed up to maximum and leaking around cover, also allowing for the ingress of water. 74 SOLAS(14) I/11
Pollution Prevention/Response › Response Equipment › Protective Clothing
Issued 27 July 2017
Resolved
0900: Eyewash and Shower stations shall be available on deck in convinient locations. PSCO noted eyewash station midships did not supply adequate pressure for intended use and foot pedal did not operate. MARPOL II/7, IBC 14.3.4
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Electric Bonding
Issued 27 July 2017
Resolved
0999: Condition of ship and equipment shall be maintained to conform w/provision of present regulation to ensure ship in all respect remains fit to proceed to sea w/out danger to ship or crew. PSCO noted cargo piping bonding is deteriorated or missing throughout. 74SOLAS(14) I/11
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 27 July 2017
Resolved
1700: Ships w/capacity of 250BBLs or more of oil shall provide transfer precedures that meet the requirements of this part. PSCO noted vssls xfer procedures did not meet standards and educated master. 33CFR155.720