MAURY USCG vessel records
← All vessels

SEAPEAK VANCOUVER

SEAPEAK VANCOUVER is a 2017 tank ship. The Coast Guard has recorded 16 inspections since 2017, most recently in March 2026, along with 8 deficiencies and 2 operational controls.

Records from 2017 to 2026. Most recent: inspection, 6 March 2026.

Built
2017
Last inspected
6 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9721401
1432477
Flag
BAHAMAS, THE
Maury page id
psix-1432477

Inspections, by type

…with no type recorded2
Years with a record 9 calendar years (2017–2026)
The 16 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it33979 - Convention (Subpart B), Net Ton
33979 - Regulatory (Subpart C or D), Net Ton
113263 - Convention (Subpart B), Gross Ton
95253 - Dead Weight, Metric Ton
131303 - Displacement, Metric Ton
113263 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 16

6 March 2026 PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8316485
6 June 2025 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8153755
18 April 2025 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8112714
8 March 2025 COC-GAS Annual · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8086173
28 January 2024 PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7854138
11 October 2022 PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7569392
9 July 2022 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7501492
23 May 2022 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7457270
20 December 2021 COC-GAS Annual · PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7366962
30 September 2020 Ballast Water Examination · COC-GAS Renew · Deficiency Check · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7063535
28 September 2020 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7062430
3 October 2019 ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6826283
20 May 2019 Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6684296
20 May 2019 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6690126
23 June 2018 ISPS II Exam · Ballast Water Examination · COC-GAS Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6443223
2 May 2017 ISPS II Exam · Ballast Water Examination · COC-GAS Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6149176

Deficiency record · 8

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 December 2021 Resolved
02108 - A gas carrier shall comply with the requirements of the IGC Code. Electrical equipment, cables and wiring should not be installed in hazardous locations unless it conforms with the standards not inferior to those acceptable to the Organization. PSCO observed IGG/GCU Inlet and Accumulator High Level Temperature Sensors located in compressor room had improperly packed housing, allowing for accumulation of flammable vapors. - 74SOLAS(20) VII/13.1; IGC Code(93)/10.1.4 - 10c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2021
Resolution: Crew fixed the issue on the spot, verified by the PSCO.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 December 2021 Resolved
07105 - Doors required to be self-closing shall not be fitted with hold-back hooks. PSCO observed hold-back hooks on multiple self-closing doors. All boundary doors should be checked against the Fire Control Plan, and brought into compliance. - 74SOLAS(20) II-2/9.4.2.2 - 40c
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 May 2022
Resolved 23 May 2022
Resolution: Vessel has removed all hooks on doors.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 30 September 2020 Resolved
The condition of the ship and its equipment should be maintained to conform with the provisions of the code to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. Several cargo leaks were discovered o the vessels number 3 and number 4 vapor domes. Inspectors noted visual and audible and meter-indicated evidence of leaks.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 October 2020
Resolved 7 October 2020
Resolution: Reviewed class report and witnessed leaks were corrected.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 30 September 2020 Resolved
Every company should develop, implement, and maintain a safety management system which includes the following functional requirements. Instructions and procedures to ensure safe operation of ships and protection of the environment in compliance with relevent international and flag state legislation. Vessel discovered cargo leaks and did not implement or maintain paper/accurate inspections for the vessels SMS. ISM Part A/1.4.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2020
Resolved 7 October 2020
Resolution: Per Class, ship has instututed oversight to ensure cargo checks are being completed accuratley.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 30 September 2020 Resolved
Whenever an accident occurs to a ship or a defect is discovered, either of which affects the sfety of the ship or the efficiency or completeness of its life saving appliances or other equipment, the master, or owner of the ship should report at the earliest opportunity to the Administration, the nominated surveyor or recognized organization responsible for issuing relevent certificate. Vessel and company failed to nitify the Administration or Recognized Organization or Nominated Surveyor when cargo leaks were discovered on number 3 and number 4 tank vapor domes.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2020
Resolved 7 October 2020
Resolution: Class was notified and inspected all deficiencies to include the vapor dome leaks.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 30 September 2020 Resolved
Objective evidence discovered in an expanded ISM exam revealed the following non-conformity; the vessel failed to fully implement the requirements of the SMS as evident by deficiency #2 and #3. An internal audit is requried within 3 months.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 December 2020
Resolved 17 November 2020
Resolution: Obtained and reviewed Torben Spirit audit report by [name withheld] with POLARIS. Report satisfies the deficiency.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 30 September 2020 Resolved
Emergency shutdown valves in liquid piping should fully close under all service conditions within 30 seconds of activation. Port side manifold valves did not close within 30 seconds. Submit class report prior to cargo operations.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 October 2020
Resolved 7 October 2020
Resolution: Class report was reviewed and an operational test of ESD's was perfomred to satisfactoin of the Coast Guard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 September 2020 Resolved
Whenever there is a hazardous condition either on board a vessel or caused by a vessel or its operation, the owner, agent, master, operator, or person in charge must immediatley notify the nearest Coast Guard Sector Office or Group Office and in addiditon submit and report required by 46CFR4.05-10. Coast Guard was never notified about the vapor dome leaks by the owner, agent, master , operator, or person in charge.
Action required: 10 - Deficiency Rectified
Due 30 October 2020
Resolved 30 September 2020
Resolution: Deficiency was rectified while Coast Guard Marine Inspectors were on board.

Ownership record