MAURY USCG vessel records
← All vessels

VL BRILLIANT

VL BRILLIANT is a tank ship. The Coast Guard has recorded 4 inspections since 2017, most recently in April 2026, along with 3 deficiencies.

Records from 2017 to 2026. Most recent: inspection, 15 April 2026.

Built
Not recorded
Last inspected
15 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9683673
1432678
Flag
LIBERIA
Maury page id
psix-1432678

Inspections, by type

Years with a record 4 calendar years (2017–2026)
The 4 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it319547 - Dead Weight, Metric Ton
161367 - Convention (Subpart B), Gross Ton
111506 - Convention (Subpart B), Net Ton
364796 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 4

15 April 2026 PSC B · COC-TVE Renew · COE-Administrative
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8350568
22 August 2024 COC-TVE Renew · PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7980187
18 June 2021 PSC B · COC-TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7216906
20 March 2017 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6106505

Deficiency record · 3

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 22 August 2024 Resolved
For tankers 2,000 tonnes deadweight and upwards, the protection of the cargo tanks shall be achieved by a fixed inert gas system in accordance with the requirements of the FSS Code. PSCO discovered the #2 blower inoperable due to a wasted motor bearing. Vessel has place a procurement request on 18AUG24 for spare parts. 74SOLAS(2014) II-2/4.5.5.1.1 FSS Code 15.2.3.1.4.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2024
Resolved 18 November 2024
Resolution: Received and reviewed satisfactory class report attesting to the repair of the blower moter bearing.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 22 August 2024 Resolved
For tankers 2,000 tonnes deadweight and upwards, a fixed deck foam fire extinguishing system shall be provided complying with the FSS Code. Vessel could not provide water to foam monitors in excess of 20 minutes. Foam monitors #6 and #8 supply valve were found seized shut. Crew had recently overhauled foam pump and failed to re-prime the pump. In addition, SMS/drill schedule only requires the foam monitors to be tested once a year. The deck foam system shall be capable of simple and rapid operation. 74SOLAS(14) II-2/ 10.8.1.1 FSS Code 14.2.1.2
Action required: 10 - Deficiency Rectified
Resolved 22 August 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 August 2024 Resolved
The arrangements for storage and distribution of other flammable oils employed under pressure to power transmission systems, control and activating systems shall be such as to ensure the safety of the ship and persons on board. Excessive hydraulic oil was found in vicinity of the M/E high pressure fuel pumps on all cylinders. 74SOLAS(14) II-2/4.2.4
Action required: 10 - Deficiency Rectified
Resolved 22 August 2024

Ownership record