MAURY USCG vessel records
← All vessels

ZODIAC

ZODIAC is a passenger vessel (inspected). The Coast Guard has recorded 10 inspections since 2017, most recently in August 2023, along with 9 deficiencies.

Records from 2017 to 2023. Most recent: inspection, 9 August 2023.

Built
Not recorded
Last inspected
9 August 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 August 2023
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2017–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDL5341
1433121
Flag
UNITED STATES
Maury page id
psix-1433121

Documentation record

Tonnage as PSIX records it5 - Regulatory (Subpart C or D), Gross Ton
0 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 10

9 August 2023 Administrative Inspection · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7764277
9 August 2023 In-Service Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7781388
20 October 2021 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7336647
23 February 2021 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7149483
22 February 2021 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7144130
19 November 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7098510
18 November 2019 Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6858665
4 October 2018 Plan Review "T" Boat · COI Inspection · In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6584333
28 March 2018 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6380339
1 March 2017 Administrative Inspection · Plan Review "T" Boat · Hull Examination · Simplified Stability Test
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6097141

Deficiency record · 9

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 February 2021 Resolved
Vessel's fire detector in the fuel tank space is not intrinsically safe. Remove existing fire detector and replace with Coast Guard approved, intrinsically safe fire detector that alarms at the helm. Vessel may only operate as an uninspected passenger vessel as per the COI's 'routes and conditions' until deficiency is corrected.
Action required: 705 - Other - as specified
Resolved 1 August 2025
Resolution: This deficiency is no longer relevant due to modifications of the affected space.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 November 2020 Resolved
Vessel is overdue for a dry dock exam. Complete the required dry dock exam prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 February 2021
Resolution: Vessel completed credit hull exam.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 May 2020 Resolved
Vessel's fire detector in the fuel tank space is not intrinsically safe. Remove existing fire detector and replace with Coast Guard approved, intrinsically safe fire detector that alarms at the helm. To be completed by next dry dock exam. 46 CFR 181.400(c) and 46 CFR 182.410(a).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 22 February 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 April 2020 Resolved
THE FIXED FIRE EXTINGUISHING SYSTEM CYLINDER WAS FOUND TO BE UNDERCHARGED. ENSURE CYLINDER IS PROPERLY CHARGED.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 May 2020
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 April 2020 Resolved
DURING COI, MARINE INSPECTORS WERE UNABLE TO PROPERLY TEST THE REQUIRED FIRE DETECTION ALARM FOR THE SPACE CONTAINING THE GASOLINE FUEL TANK. ENSURE TEST IS CONDUCTED IN THE PRESENCE OF USCG MARINE INSPECTORS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 May 2020
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 April 2020 Resolved
VESSEL DID NOT HAVE THE REQUIRED PORTABLE FIRE EXTINGUISHER AT THE OPERATING STATION. ENSURE A 10-B:C TYPE EXTINGUISHER IS PROPERLY INSTALLED AND READILY ACCESSIBLE.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 May 2020
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 6 April 2020 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 1 May 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 April 2020 Resolved
LIFE RING BUOYS DID NOT HAVE TYPE II RETROREFLECTIVE TAPE AS REQUIRED. INSTALL PROPER RETRO TAPE ON LIFE RING BUOYS.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2020
Resolved 1 May 2020
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 April 2020 Resolved
VESSEL'S FIRST AID KIT IS NOT CERTIFIED AS MEETING 46 CFR 160.041 AND DOES NOT HAVE EQUIVILANT CONTENTS. PROVIDE A FIRST AID KIT THAT IS EITHER 46 CFR 160.041 CERTIFIED OR HAS EQUIVILANT CONTENTS AND INSTRUCTIONS.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2020
Resolved 1 May 2020

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.