Records in 2017. Most recent: inspection, 17 April 2017.
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 18 April 2017
No resolution recorded
Code:1499 Cite:74SOLAS(2004)II-2/4.2.2.5.2 Action: 40ac External high-pressure fuel delivery lines between the high-pressure fuel pumps and the fuel injectors shall be protected with a jacketed piping system...The jacketed on fuel injectors lines on the main engine had frays and temporary repairs in multiple locations.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Fire Fighting › Fire Main › Condition
Issued 18 April 2017
No resolution recorded
Code:0720 Cite: 74SOLAS (2014) I/11 Action: 40ac The condition of the ship and its equipment shall be maintainedto conform with the provisions of the present regulations...The vessel's fire main has a slow leak on the port side, amidship.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 18 April 2017
No resolution recorded
Code: 0830 Cite: 74SOLAS(2004)II-1/45.1.3 Action: 40ac All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched. There were multiple exposed wires hanging within the SOPEP locker.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Fire Fighting › Firemans Outfit › Quantity
Issued 18 April 2017
No resolution recorded
Code: 0735 Cite: 74SOLAS(2004) II-2/18.5.6 Action: 40ac The following fire-fighting appliances shall be provided in addition to the requirements of regulation 10.10, two sets of fire-fighting suits on board. The vessel only has 03 sets of fire-fighter's outfits on board, 04 is required for vessels conducting helo-ops.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Fire Fighting › Structural - A Class Divisions › Control Stations
Issued 18 April 2017
No resolution recorded
Code:0750 Cite:74SOLAS(2004)II-2/2.1.1.4 Action: 40ac In order to achieve the fire-safety objectives see out in paragraph 1, the following functional requirements are embodied in the regulations of this chapter as appropriate: containment and extinction of any fire in the space of origin. The A Class boundary in the pipe trunk space on the C Deck has multiple through-holes.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Stability › Weathertight Integrity › General
Issued 18 April 2017
No resolution recorded
Code: 1240 Cite:ICLL 66 Reg 14(1) Action: 40ac The constuction and the means for securing the weathertightness of cargo and other hatchways...The permanent hatch cover to the cofferdam on the port side was not weathertight.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 18 April 2017
No resolution recorded
Code: 0999 Cite: 74SOLAS(2014)I/11 Action: 40ac The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present regulations...The stairs leading to the top deck, above the nav bridge were severly corroded to the point of giving way under normal pressure.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 18 April 2017
No resolution recorded
Code: 0999 Cite: 74SOLAS (2014) I/11 Action: 40ac The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations...Pipes in the A Deck trunk space were leaking, accumulating about an inch of water.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign